| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹1.7 Cr | L1 | Accepted-AOC Being lowest |
| 2 | L2₹1.7 Cr+₹3.9 L (2.31%)Rejected-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | ₹1.7 Cr+₹3.9 L (2.31%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹1.8 Cr+₹5.9 L (3.47%)Rejected-Finance | ₹1.8 Cr+₹5.9 L (3.47%) | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹1.9 Cr+₹20.2 L (11.9%)Rejected-Finance | ₹1.9 Cr+₹20.2 L (11.9%) | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹2.1 Cr+₹42.6 L (25.1%)Rejected-Finance | ₹2.1 Cr+₹42.6 L (25.1%) | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
14 Oct 2020, 6:00 pmClosed
CHIEF ENGINEER CG GOA
HQ CE CG GOA 403806
AUGMENTATION OF ELECTRIC SUPPLY AT CG JETTY PORBANDAR
2020_MES_345005_3
81081/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
PORBANDAR
As per tender document
8 documents required · 8 mandatory
₹2,000
Yes
GE (I) (CG) PORBANDAR
₹2.9 L
Yes
9 Nov 2020
22 Sept 2020
16 Oct 2020
22 Sept 2020
14 Oct 2020
30 Sept 2020
Amount
Supply, laying and testing cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade (earth grade ) with stranded copper conductor of size 240 sqmm 3.5 core all as specified Make :- Ravin / Havells Cables / KEI / RR kablesNote :- Earth work , cable cover, sand cashioning & cable protection pipe will be measured & Paid separately under respective ttems of this BOQ.
Supply, laying and testing cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade (earth grade ) with stranded aluminuim conductor of size 240 sqmm 3 core all as specified :- Make :- Ravin / Havells Cables / KEI / RR kabel Note :- Earth work , cable cover, sand cashioning & cable protection pipe will be measured & Paid separately under respective items of this BOQ
Supply, laying and testing cable XLPE Insulated , screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor of 300sqmm x3.5 core size. Make :- Ravin / Havells Cables / KEI / RR kables Note :- Earth work , cable cover, sand cashioning & cable protection pipe will be measured & Paid separately under respective ttems of this BOQ.
M&L for Bore Earthing complete with solid copper rod earth electrode 19 mm dia, 1800mm length, buried directly and preferably vertically in ground connected with earthing lead of 16 Sqmm dia PVC insulated single core copper conductor flexible cable including FRP Chamber and testing on completion all as specified and directed. Note :(i) Dimensions of FRP Chamber should be 300X300mm Top, 150mmX150mm Bottom, 200 mm Height and 2 mm Thickness.(ii) Cost of 16 Sqmm Copper Cable and 20 mm dia HDPE pipe (6Kg/Sqcm) deemed to be included in unit rate up to 7.5 meter.(iii) Value of earth system resistance should be less than 2 ohms.(iv) Cost of Bore hole of 150mm OD upto 3 M deemed to be included in unit rate.(v)Cost of Earth Enhance material to achieve the required result deemed to be included in unit rate.
Sypply , installation, commissioning and testing of AC, 3 Phase, 50 HZ 1000 KVA capacity transformer step down indoor type 11/0.433 KV (at no load) copper wound, Dry type complete , lifting hooks wheel with channel and locking arrangement to put on the plinth with external cooling , core type delta connected on primary (HV) side star connected on secondary (LV) side in accordance with vector symbol DYN-11 (vector group - 4) and netural brought on secondary side , On load tap changer with automatic voltage regulation (AVR) in suitable steps/position (Tapping Range +5% to -15% in steps of 1.25% each) on HV side to give output of stabilised voltage on LV side and Remote tap cubical changer (RTTC) Panel, digital type winding temperature indicator with RTD sensor and with standard accessaries and connecting with electrical system earthing etc including all jointing materials PCC foundation as per OEM design/recommendation testing and commissioning all as per IS : 11171 complete all as specified and directed. Make :- ABB / CG/ Areva / ITE /Andrew Yule/BHEL. Note :- Rate of HV cable box/LV cable box (for bus duct termination)/marshelling box deemed to be included in unit rate.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 240 Sqmm x3 core (Earth Grade) all as spd Make :3M, Denson , raychem, RPG.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of 240sqmmx3 core size.(Earth Grade) all as spd Make :3M, Denson , raychem ,RPG
Supply and fix cable jointing kit for 11 KV grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core xlpe armoured aluminium conductor cable of size 240 Sqmm x3 core .(Earth Grade) all as spd Make :3M, Denson , raychem ,RPG
Supply and Instal Compact cast resin type copper bus bar trunking system ETP 99.9 as per IEC 61439-6, 1250Amp, 1000V, 50Hz, 45KA for 1 sec and outer casing consists of 4C ribbed section bolted and riveted (thickness 1.5 mm) with excellent mechanical electrical and heat loss efficiency. The sheet metal is made of Hot galvanised steel treated according to UNI EN10327 and painted with RAL 7035 resins with a high resistence to chemical agents and degree of protection IP 68(Outdoor) all as spd and directed. Note: Cost of plugin hole,elbow 90 degree fabrication, end cover and switch board feed unit deemed to be included in unit rate. (ii)Hot dip galvanized horizontal supporting bracket and vertical spring hanger deemed to be included in unit rate. (iii) Interconnecting links required for termination deemed to be included in unit rate. Make: Legrand/ABB/Schneider/ Siemens
Supply and install Compact sandwich type copper bus bar trunking system as per IEC 61439-6, 600 Amp, 1000V, 50Hz, 36KA for 1 sec and outer casing consists of 4C ribbed section bolted and riveted (thickness 1.5 mm) with excellent mechanical electrical and heat loss efficiency. The sheet metal is made of Hot galvanised steel treated according to UNI EN10327 and painted with RAL 7035 resins with a high resistence to chemical agents and degree of protection IP 55(Outdoor) all as spd and directed. Note: Cost of plugin hole,elbow 90 degree fabrication, end cover deemed to be included in unit rate. (ii) Hot dip galvanized horizontal supporting bracket and vertical spring hanger deemed to be included in unit rate. (iii) Interconnecting links required for termination deemed to be included in unit rate. Make: Legrand/ABB/Schneider/ Siemens
Supply installation and testing of 3 phase and neutral, 415 volts factory made ,outdoor type,IP 54 free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 3.00 mm thick ( minimum) CRCA sheet with epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of busbars made of high conductivity 99.9% pure copper of ETP grade suitable for 1200amps pre-wired with suitable size of copper strip, short circuit rating 50 KA (rms) for one second including suitable aluminium earth strips and comprising of (a) ACB 800 amps 4 pole ultimate breaking capacity 50 KA draw out type , provided with Microprocessor based release , self powered type without aux power supply during normal operation with LED screen ,motorised operating system suitable for 415V ,Adjustable overload setting from 40% to 100% of rating of ACB (in)over load setting (tr) from 5-10-20-30 s , short circuit rating from 1.5 to 10 times with time delay 01 No. (b ) Outgoing busbar chamber of appropriate rating (c ) Digital Multifunctional Panel meter of size 96X96 mm and three current transformer of suitable ratio and capacity 01 set Make of MCCB : Legrand (DPX3) MP4 Release /ABB (XT)/Siemens (3VA)/Schneider(NSX)/L&T/C&S Make of panel: Schneider /Siemens /Legrand/ABB/L&T/C&S
Supply and fix outdoor type IP 54 Tap off Box Plug in suitable for MCCB 4 pole 250 Amp complete with MCCB electronic release type 36 KA , including SIP PIB 250 A Rotary handle and spreader links for connections , all as specified Make :- Legrand , Schneider / Siemens /ABB
Supply and fix outdoor type IP 54 Tap off Box Plug in suitable for MCCB 4 pole 100 Amp complete with MCCB electronic release type 36 KA , including SIP PIB 100 A Rotary handle and spreader links for connections , all as specified Make :- Legrand , Schneider / Siemens /ABB
Taking out old unservciable rusted LT panels all as directed by engineer-in-charge.
Taking out old unservciable rusted LT Cables including dismantling the electric cable connections complete.
Taking out old transformer Cap 630 KVA including disconnecting and dismantling the electric cable HT/LT side complete and deposit in store for stand by use
Supply installation and testing of 3 phase and neutral, 415 volts factory made, indoor type,IP 43 free standing, floor mounting, dust and vermin proof cubical type, LT panel fabricated from 1.6 mm thick ( minimum) CRCA sheet with anti corrosive coating and finally epoxy polyester powder coating of flint Grey shade (RAL-7032), fully compartmentalized design with 4 Nos of busbars made of high conductivity 99.9% pure copper of ETP grade suitable for 1600amps pre-wired with suitable size of copper strip, short circuit rating 50 KA (rms) for one second including suitable aluminium earth strips and comprising of (a) ACB 1600 amps 4 pole ultimate breaking capacity 50 KA draw out type with Microprocessor based protection unit with LED screen ,motorised operating system suitable for 415V-01 No (incoming ) (b )ACB 1250 amps 4 pole ultimate breaking capacity 50 KA draw out type with Microprocessor based protection unit with LED screen ,motorised operating system suitable for 415V -01 No out going (c) MCCB 630A 4 pole ultimate breaking capacity 36 KA with electronic releases suitable for 415V 01 No (APFC ) (d ) Digital Multifunctional Panel meter of size 96X96 mm and three current transformer of suitable ratio and capacity 01 SET. Make of panel :- Schneider(Block Set) /Siemens (Sipan) /Legrand(XL3)/ABB(RTUK)/L&T(TI)
Material and labour for Hot dip galvanized support for cable /pipe etc as per site condition such as C brackets, Angles, threaded rod etc complete all as spd and directed
Supply and lay 160/136 mm Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables, laid in trenches/ road/ drain or fixed along wall,poles or laid under floor all as spd and as directed by Engr-In-Charge. Make-REX/POLY/Gemini.
Excavation in trenches not exc 1.5 m wide and not exc 1.5m in depth and getting out in Hard/Dense soil complete all as specified and directed.
Returning filling in incl spreading levelling watering and well Ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing excavated material not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified.
Supply & Lay dry river sand in existing duct/trenches for cable protection all as specified and directed.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5mt depth for foundation, etc., and getting out in any type of soil.
M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation and mass concrete complete as specified and directed.
Dismantling of Brickwork or stone/boulder laid dry and proper base for duct near sea portion boulder removed up to depth 1.50mtr and throw away not exc 10mtr at throughout length of duct upto 2000 mtr. Near Sea portion at Jetty complete all as specified and-directed by-Engineer.in.Charge,
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter in rough finished surfaces of concrete complete all as specified and directed by Engineer in-Charge
M&L RCC M-30 (using 20mm graded stone agg) as in foundation, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under reamed pies and mass concrete, complete all as specified and directed by Engineer in Charge.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railıng and similar work including attached pillasters, buttresses, etc; vertical or to batter etc complete all as specified and directed by Engineer.in Charge
RCC M-30 (using 20mm graded stone aggregate) as in Walls, retaining walls, basement walls and the like, any thickness, above top of footings, including attached pillasters and buttresses etc complete all as specified and directed-by-Engineer in charge.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia or securing with clips complete all as specified and directed by .Engineer in-Charge.
M&L for rendering 10 mm thick on fair face of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement etc complete all as specified and directed by Engineer in Charge.
M&L for Preparation of surfaces and applying two coats of cement base paint over a coat of primer complete all as specified and directed by Engineer in Charge.
S & F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid n trenches or in floors as a weep hole in RCC wall etc complete all as specified and directed by Engineer in Charge.
ASCENT ELECTRIFICATION ENGINEERS
SHOBHIT BUILDERS
simms engineering pvt ltd
JAZZCON ENGINEERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .