Executive Engineer RNB electrical Division Sgr
Executive Engineer RNB electrical Division Sgr
Providing of Internal Electrification of transit accommodations Block No - R ( 16 Flats ) at Khowjabagh Baramulla.
2022_PWDJK_176237_3
E/NIT/49/2022/23dtd27/06/2022
Open Tender
Electrical Works
Item Rate
Providing of Internal Electrification of
As per BOQ
2 documents required · 2 mandatory
₹600
Executive Engineer RNB electrical Division Sgr
₹29,620
5 Jul 2022
27 Jun 2022
5 Jul 2022
28 Jun 2022
5 Jul 2022
28 Jun 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x 1.5 sq.mm (P+N) FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked , to be laid in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (excluding cost of conduit) but including cost of circuit wiring from DB to first switch in sub circuit.complete job .
Providing of Wiring for Power plug points (16 Amps socket outlet points) with 3X4 sq. mm FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked,to be laid in surface/ recessed PVC conduit along as required with making of necessary connections ( excl cost of Conduit ) but including cost of circuit wiring from DB to first switch in sub circuit.complete job.
providing and laying of Wiring for 6 Amp Socket Out Points with 3X2.5 sq. mm FRLS PVC insulated copper conductor single core cable of srandard make dully isi marked,to be laid in surface/ recessed PVC conduit ,including making of necessary connections ( excl cost of Conduit ) but including cost of circuit wiring from DB to first switch in sub circuit.complete job .Total quantity
Providing and laying of Wiring for submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of srandard make dully isi marked,to be laid in surface/ recessed medium class PVC conduit as required
2 X 16 sq. mm + 1 X 16 sq. mm earth wire .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required .
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required
Supply and Fixing of two module stepped type Electronic Fan regulatot on the existing modular plate switch box including connectionsetc as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, SPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required .
8 way (4 + 24), Double door
Supplying and fixing 5 A to 32 A Single pole rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 40-63 Amp 240/415V, 10 kA, "C" curve, miniature circuit breaker Double pole suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc.
Supplying and fixing 32 Amp 240/415V, 2 Module Change over Switch fitted in excisting D Box incl making of necessary connections
Supply and Fixing of Neon Indicator Modular Switch Series incl its Frame Plate, cover plate and G I Box of required size
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supply and Fixing of 12 /15 Watt Surface mounted Slim / Recessed type LED Fixtures of Standard make dully ISI marked .With necessary Connections Complete Job .( approved before inistallation )
Supply and fixing of 14 Watt Batten Type Al Base LED Light Fixture of standard make as mirror lights of Standard make dully ISI marked . With necessary connections complete job .
Supply and fixing of 1400 mm sweep Ceiling Fans complete in all respects With necessary connections complete job .
Supply and fixing of 250 mm sweep Shutter type Exhaust Fans complete.
Supply and fixing of 30 watt LED (IP67) street Light made of pressure die cast Aluminum Housing with high power LEDs, Lens & Toughened glass IP66 fitted on ornemental L Bracket Complete
Supply and fixinf of AC / DC Bells with its Batteries.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and in slab making good the same in case of recessed conduit as required for repairs or laying of additional conduits whereever required
Design, Fabricataion, assembly, Installation, Testing and Commissioning of Front Operated Cubicle type compartmentalised as per form 3B free standing, dust and verim proof (IP 42 ingress protection) LT panel suitable for use of 415 volts, 3 Phase 4 wire 50Hz suitable for a fault levewl of 55kA at 415 volts, fabricated from 2 mm thick Powder coated paint finish of approved shade CRCA MS sheet with hinged, gasketted9 metal based neoprene) and lockable doors having structral reinforcement with suitable angle/ chanel/T / Flat section uncl gland plates as requiredand lifting hooks with sleeved TPN AL Busbars and G I strip of required size with 2 no earthinmg terminals complete with interconnections as required for MCB`s and control wiring .Each incoming / out going breakers shall have thermal megeatic release. The panel will be made as oper detailed specifications and drawings formating part of this document. Incomer :- 1 No 250 Amp TPN MCCB with beaking capacity 50 kA with thermal release and adjustable settings. 1 Set of R,Y,B Phase indicating lamps 1 No MFM with 630/5CT coils 1 Set of 500 Amp TPN Alluminum Bus Bar with colour coding sleeves Out Going :- 16 No 100 Amp D Pole MCB`s 6 No 32-40 Amp D P MCB`s 2 no 63 Amp TPN MCB
Supply, laying, jointing, terminating, testing and commissioning of 185 sq mm 3.5 Core 1100 V grade, armoured,PVC/ XLPE, aluminum(AL) conductor cables of ISI Make on existing trays/walls/columns/ trenches including the cost of supports with suitable clamps, saddles, hooks, bolts etc. and including the cost of proper dressing of cables, markers providing identification tags, earthing of glands armouring etc complete.
Providing & Laying of 100 mm dia ISI Marked PVC Pipes dully laid for carring power cable including cost of connecting bends, collars , etc complete .
Providing & Fixing of MS Celling fan boxes to be laid in the slab
Providing & Fixing of Lighting Deep Junctions boxes to be laid in the slab
Chemical Earthing with 3 mts long GI electrode to 50 mm dia G I Pipe placed verticaly in 100 mm dia bore dully drilled with hand drill and filed with required quantatity of chemical and man hole cover at top. The job includes extending of Earthing fron Eart Electrode to Main L T panel with 19 x5 mm G I Strip in one run
M/s AHKHAN ENTERPRISES
M/s NEW LIGHT ENTERPRISES
NALSAB GLOBAL PRIVATE LIMITED
stage.html
html • 0.02 MB
finance_423766.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .