| Sl No | Description | Qty | Unit | RASHEED P. L1 | ASKAR KARATTIL L2 |
|---|---|---|---|---|---|
| 1.00ELECTRIFICATION | |||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 12 | point | 1,172.2 ₹14,066.4 Lowest | 1,184.04 ₹14,208.48 |
| 1.00 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire | 25 | metre | 172.41 ₹4,310.25 Lowest | 174.15 ₹4,353.75 |
| 1.00 | 1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 10 | metre | 197.38 ₹1,973.8 Lowest | 199.37 ₹1,993.7 |
| 1.00 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire | 15 | metre | 237.28 ₹3,559.2 Lowest | 239.68 ₹3,595.2 |
| 1.00 | 1.14.8:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire | 20 | metre | 364.78 ₹7,295.6 Lowest | 368.46 ₹7,369.2 |
| 1.01 | OD380384/2024-2025:Supply Conveyance, installation, testing and commissioning of 50 W LED Flood light with IP 65 protection LED Chip make acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver ompartment should be seperatly accessible for maintenance including giving connections with required length of PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire ect as required | 1 | each | 2,399.01 ₹2,399.01 Lowest | 2,423.24 ₹2,423.24 |
| 1.01 | OD380385/2024-2025:Supply, conveyance and fixing 12W LED Square of recess/surface mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc as required.(Bajaj, Osram, Philips, Crompton, Dewton make) | 12 | each | 770.72 ₹9,248.64 Lowest | 778.51 ₹9,342.12 |
| 1.01 | OD380394/2024-2025:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required | 1 | each | 783.72 ₹783.72 Lowest | 791.64 ₹791.64 |
| 1.01 | OD392835/2024-2025:Supply, Conveyance, installation, testing and commissioning of 450 mm sweep wall mounting fan with Bracket & Motor Assembly, Guard & Blade air delivery 100 CMM and above etc with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS (Orient electric tornado Wall II chrome/Crompton SStorm2 450mm mm/Havells V3 45cm/Almonard 18” (450mm) Mark-II make) etc as required. | 5 | each | 3,802.92 ₹19,014.6 Lowest | 3,841.33 ₹19,206.65 |
Tender Value
₹1.2 L
EMD Value
₹3,007
Closing Date
22 Feb 2025, 12:00 pmClosed
BINU ET
SECRETARY BLOCK PANCHAYATH AREEKODE
Annual Plan 2024 Areacode Block Panchayath ELECTRIFICATION OF PUBLIC LIBRARY IN KAVANNOOR GRAMA PANCHAYATH SO299 /25 General elctrical work
2025_CRD_736783_2
LSGD/BP/ARD/MPM/73/2025-D
Open Tender
Electrical Works
Item Wise
180 days
KAVANNOOR
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹3,007
Yes
12 May 2026
11 Feb 2025
25 Feb 2025
11 Feb 2025
22 Feb 2025
11 Feb 2025
Amount
ELECTRIFICATION
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.8:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
OD380384/2024-2025:Supply Conveyance, installation, testing and commissioning of 50 W LED Flood light with IP 65 protection LED Chip make acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver ompartment should be seperatly accessible for maintenance including giving connections with required length of PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire ect as required
OD380385/2024-2025:Supply, conveyance and fixing 12W LED Square of recess/surface mounting down light fittings of all types complete with all accessories in the existing opening of false ceiling, giving connections with the existing wire etc as required.(Bajaj, Osram, Philips, Crompton, Dewton make)
OD380394/2024-2025:Supply and fixing 12W LED bulk head fitting heat resistant prismatic glass cover to wall / ceiling including giving connections with required length of PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
OD392835/2024-2025:Supply, Conveyance, installation, testing and commissioning of 450 mm sweep wall mounting fan with Bracket & Motor Assembly, Guard & Blade air delivery 100 CMM and above etc with required length of 16/0.20mm PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS (Orient electric tornado Wall II chrome/Crompton SStorm2 450mm mm/Havells V3 45cm/Almonard 18” (450mm) Mark-II make) etc as required.
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
1.56:Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.17.6:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD380362/2024-2025:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system
OD380352/2024-2025:25 mm X 3 mm G.I. strip earth lead Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD380360/2024-2025:Supply and providing 25x6mm brass nut and bolt etc. as required.
90.12.7.40:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
9.1.32:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
OD380359/2024-2025:Supply and installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-4537-NF ] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required
2.1.1:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.32 Amp TP & N
OD380353/2024-2025:Supplying and fixing 32A, HRC Fuse with HRC Fuse link with connections, in existing meter board
OD380355/2024-2025:Supplying and fixing 32 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board
OD380361/2024-2025:Supplying and providing M8 Anchor bolt in wall/parapet for bimding support of KSEB service main etc as required.
OD380407/2024-2025:Supplying and fixing of following sizes of light class PVC conduit along with accessories in surface/ recess including cutting the wall/ground and making good the same in case of recessed conduit as required as service pipe
OD380406/2024-2025:Charges for procurement, preparation and submission of application for availing single/three phase KSEB service connection with necessary Sketch, Test and completion report, etc. including necessary liaison work as required
ASKAR KARATTIL (BID ID -2119985)
Bidder Name
RASHEED P.
ASKAR KARATTIL
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1181730.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.03 MB
Tendernotice_2.pdf
PDF • 0.03 MB
Tendernotice_3.pdf
PDF • 0.02 MB
PLA.pdf
Tender Documents • 0.12 MB
BOQ_1181730.xls
BOQ • 0.25 MB
AFD.pdf
Tender Documents • 0.10 MB
FOB.pdf
Tender Documents • 0.01 MB
SBD.pdf
Tender Documents • 1.63 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .