Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹18.9 L+₹85,280 (4.74%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹18.9 L+₹91,985 (5.11%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹19.3 L+₹1.3 L (7.35%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹20.0 L+₹2.0 L (11.1%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
18 Jun 2020, 6:00 pmClosed
GE Kargil
GE Kargil, Ladakh
REPAIR AND MAINT OF STREET LIGHTS, MISC ITEMS AND ALLIED WORKS AT BUDHKHARBU AND KARGIL
2020_MES_348379_1
GE/K-37/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Budhkharbu Kargil
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Kargil
₹82,000
Yes
3 Aug 2020
30 May 2020
20 Jun 2020
30 May 2020
18 Jun 2020
13 Jun 2020
Amount
M&L for Excavation in trenches, in hard/dense of soil not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation etc. or for shafts wells, cesspits, manholes, pier holes, laying of cables, post holes for poles/ stays etc n. exc. 10 sq.m on plan and getting out,complete all as specified and directed by the Engr-in-Charge.
M&L for Returning filling in with approved excavated soil including spreading levelling watering and well remming in layers not exceeding 25cm thick,complete all as specified and directed by the Engr-in-Charge.
M&L for Removal of surplus soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point ,complete all as specified and directed by the Engr-in-Charge.
M&L for Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I ,complete all as specified and directed by the Engr-in-Charge.
S& F Un-reinforced precast cement concrete cable cover conforming to class LV Type-I , flat of size 250mmx150mmx 40mm, laid dry over electric cable for protection,complete all as specified and directed by the Engr-in-Charge.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-31 (9.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed by the Engr-in-Charge.
Taking down/out UG cable any size from trenches/pole etc
S& F XLPE insulated PVC sheathed, armoured heavy duty electric cable with aluminium conductor, 1100 volts, cross-sectional area 16 Sqmm 4 core laid in trenches/ducts, passing through pipes or along poles including taking out old/unserviceable cable,complete all as specified and directed by the Engr-in-Charge.
All as per item No 10 above but cable size 2 C x 10 sqmm -ditto-
All as per item No 10 above but cable size 3.5 C x 35 sqmm -ditto-
M&L for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 type B-1 (using 20mm grade aggregate) as in coping including all necessary form works complete all as specified and directed by Engineer-in-Charge
Taking down street light/flood light/garden light fittings any type any capacity complete
S&F Street light bracket made out of GI pipe 35mm dia light grade 1.2 mtr duly bended in position as per site requirement and including 2 Nos and 2 set MS flat iron clamps of suitable size complete with 03 set nut , bolts and washers for mounting street lights,complete all as specified and directed by the Engr-in-Charge.
S&F LED street light 40 watt IP 66 Pressure die cast aluminium housing Cat part-Philips BRP 409 LED 040 CW HO MRFG S1 PSU GR of Philips or equivalant make of CG and Havells comprising of epoxy powder coated housing enclosed with glass cover in frame 40X1. watt LED mounted on MCPCB complete all as specified.
S&F LED street light 72 watt IP 66 Pressure die cast aluminium housing Cat part-Philips BRP 410 LED 072 MR FG S1 PSU GR of Philips or equivalant make of CG and Havells comprising of epoxy powder coated housing enclosed with glass cover in frame 91X1. watt LED mounted on MCPCB complete all as specified.
S&F globe integral pole mounted decorative 25 watt LED post top with spherical shaped polycarbonate cennecting up electrically all as specified & directed. Make -Bajaj 111741-BLPTSP25W NW LED, equivalent in Philips/CG/Havells
Supply and fixing of LED Flood light LED 30 W with high pressure die cast housing and IP65 Protection,complete all as specified and directed by the Engr-in-Charge.Make Bajaj Cat Part No. BJFL30WLED or equivalvent in Havells/Philips.
S&F Cable junction box of size not more than 250x150x75 mm with 6 Amp MCB SPN and Al bus bar fixed along the wall/pole without removing and preparation of surfaces for painting externally. Painting the cable junction box complete externally by applying one coat of synthetic enamel paint of approved colour , complete all as specified and directed by the Engr-in-Charge.
M& L for PVC cable 1.5 sqmm for controlling street light including clamp, nuts and bolts , complete all as specified and directed by the Engr-in-Charge.
M&L for GI tubes galvanised iron light grade 40 mm bore laid in trenches/across roads/alongwith walls/poles as protection to cables and including taking down of old unservicable GI tubing,complete all as specified and directed by the Engr-in-Charge.
S&F Sheet metal enclosure for DB’s, single door single pole and neutral, 240V, 8 way including blanking plates where required, complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
S&F Sheet metal enclosure for DB’s, single door single pole and neutral, 240V, 4 way including blanking plates where required, complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
S&F Sheet metal enclosure for DB’s, single door single pole and neutral, 240V, 2 way including blanking plates where required, complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
S&F MCB, Triple pole and neutral, 32 to 63 Amp, 415 volts, 10 KA , complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
S&F MCB, single pole and neutral, 40 Amp, 240V, 10 KA, complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
S&F MCB, single pole 32 Amp, 240V, 10 KA, complete all as specified and directed by the Engr-in-Charge. Make: Havells, L&T, Indo Asian
Rectangular block of second class hard wood of size 30 x 25 x 5 cm depth, closed recessed, complete all as specified and directed by Engr-in-Charge.
Earthing complete with steel earth plate electrode 600mmx600mm x6mm thick buried directly in ground (earth plate not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level connecting to the galvanised iron earth wire 4.0mm dia by means of bolts, nuts, check nuts and washers of GI and steel earth wire including provision of concrete pit made from PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in pit, angle iron 25x25x6mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, medium grade GI watering pipe 20mm bore with funnel, wire mesh and light grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, salt, charcoal, etc. including excavation and earth work in any type of soil, removal of surplus spoil to a distance not exc. 50m complete all as shown in electrical plate No.3 of MES Schedule 2009 (Pt-I) and connected to earth test point all as specified including testing on completion.
S&F retrifit lamp 85 watts holder type warm white 220-240 volt AC
S&F PVC conduit pipe med grade ISI marked 25 mm dia with fittings
Supply and laying PVC flat cable 1100 volts grade heavy duty cable with PVC insulated aluminium conductor multistranded 10 Sqmm. 2 core in service connections, complete all as specified. and directed by Engr-in-Charge.
Cleaning the extend exposed surfaces of steel tubular pole of 9 Metre long including with cross arms, brackets clamps etc and painting complete ( Except embedded portion) including all MS work mounted on pole , earth protection & water pipe ( if exists) with one coat of aluminium paint and providing 05 Nos bands/ straps with synthetic enamel paint ( black and yellow 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black ground complete all as specified with painting of top of pole with silver paint, complete all as specified. and directed by Engr-in-Charge.
Thimble aluminium eye type suitable for cable up to 70 sqmm including necessary crimping with crimping tools, complete all as specified. and directed by Engr-in-Charge.
Thimble aluminium eye type suitable for cable up to 95/120 sqmm including necessary crimping with crimping tools, complete all as specified. and directed by Engr-in-Charge.
Aluminium strip as in earth connection of plants/assets of size 25mm x 3mm, complete all as specified. and directed by Engr-in-Charge.
Aluminium strip as in earth connection of plants/assets of size 32mm x 6mm, complete all as specified. and directed by Engr-in-Charge.
S&F Change over (side handle) switch of capacity 200 Apms, 3 phase, 415 volts, 50 Hz all as specified and directed.
S&F Change over (side handle) switch of capacity 320 Apms, 3 phase, 415 volts, 50 Hz all as specified and directed.
Supply,straining and stretching of over head aluminium conductor steel reinforced (ACSR) of any size on HT/LT poles including binding and jointing the conductor with and including 14 SWG binding wire and jumpers connections with PG clamps, complete all as specified. and directed by Engr-in-Charge.
S & F of shackle type insulator Porcelain vitreous , white, brown, or green 75 mm height and 90 mm Maximum dia., with 31x3 mm galvanised steel straps and 12 mm dia bolt 1100 Volts working pressure, complete all as specified. and directed by Engr-in-Charge.
LT spacer 2 ways made out of PVC material and suitable to work on 1100 volts, complete all as specified. and directed by Engr-in-Charge.
LT spacer 4 ways made out of PVC material and suitable to work on 1100 volts, complete all as specified. and directed by Engr-in-Charge.
LT spacer 3 ways made out of PVC material and suitable to work on 1100 volts, complete all as specified. and directed by Engr-in-Charge.
Note : - Contract sum will be derived after deduction of Rs.43955.00 as listed in Schedule `A` Part -II (Schedule of credit).
M/S TRADE LINK
M/S TAMCHOS GURMATH
M/S Web Company
M/S B K ENTERPRISES
M/S HAJI HASSAN ENGINEERING WORKS
M/S BALI CONSTRUCTIONS
M/S SUN RISE BUILDERS
M/S HIGHLAND ENGINEERING
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .