Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.4 LAccepted-AOC 45 38 15 JAGANNADHAPURAM VISAKHAPATNAM 530 016 | VISAKHAPATANAM | ANDHRA PRADESH | 530016 | L1 | Accepted-AOC 1st Lowest | |
| 2 | L2₹18.9 L+₹14,468.47 (0.77%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹19.6 L+₹80,072.27 (4.26%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹21.0 L+₹2.2 L (11.6%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹21.0 L+₹2.2 L (11.8%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
₹23.7 L
EMD Value
₹47,400
Closing Date
4 Mar 2023, 6:00 pmClosed
Garrison Engineer P Navy Kalinga Visakhapatnam
Garrison Engineer P Navy Kalinga Military Engineer Services INS Kalinga PO Visakhapatnam 531 163
SPECIAL REPAIRS TO BLDG NO. P-127 (X BLOCK) AT PHASE II RESIDENTIAL AREA UNDER SPECIAL REPAIRS B/R AT NAVAL STATION BHEEMUNIPATNAM UNDER GE (P) NAVY KALINGA VISAKHAPATNAM
2023_MES_579075_1
GE (P)/N/K/8978 OF 2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer P Navy Kalinga Visakhapatnam
Class E, Category a(i)
6 documents required · 6 mandatory
₹500
Garrison Engineer P Navy Kalinga Visakhapatnam
₹47,400
Yes
31 Mar 2023
4 Feb 2023
6 Mar 2023
4 Feb 2023
4 Mar 2023
18 Feb 2023
Amount
Taking down old tarfelt treatment from roof surfaces including plaster etc complete.
Demolition of mud phuska treatment of any thickness including plastering and leaping plaster any thickness and removes complete all as specified and directed.
M&L cutting crack to 'V' groove section in existing roof cleaning out wetting grouting with cement and sand slurry of 1:3 complete all as specified and directed.
M&L for Cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate as in roof padding over roof slab, roof kerbs or mud stop rounded or chamfered on edges all as specified & directed.
M & L for 10 mm thick screed bed on roof padding in CM 1:3 finished fair and even without using extra cement.
M&L for normal water proofing treatment on roof slab portion consisting with the following operation:- (i) Cleaning surface by wire brushes, brooming, removing dust and applying with bitumen primer conforming to IS 3384- 1986 @ 0.50 Kg per Sqm. (ii) Applying a tack coat of hot bitumen 85/25 @ 1.2 Kg per Sqm for water proofing membrane (iii) Applying of Polymeric water proofing membrane wt not less than 3 Kg per Sqm over entire area with overlapping and sealed all as specified and directed (iv) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane (v) Applying a bituminous aluminium primer/paint 0.10 kg per Sqm complete all as specified and directed.
Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames)
Taking down Chowkhats or frames exc. 1.5 sq. m but n exc 4.0 Sqm each with shutters (without taking off shutters from the frames)
Taking down & Refixing Shutters of any description exc 1 Sqm and n. exc 2 Sqm each
S&F 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, complete all as specified and as directed..
S&F angle iron/ Flat iron work as in hold fast ,support of valley gutter and nosing etc. conforming to Fe-290 Gde-165
M&L for PCC (1:3:6) type C-1 using 20 mm graded crushed stone aggregates as in hold fast block complete.
S&F II class Hard wood , factory made, 35 mm thick plain framed, panelled shutters ( Two panels),with lock rail and panel of 9 mm BWP commercial ply or 12mm veneered particles board with commercial veneering on both faces. the size of rail and stile as per IS 2009 (part-I)
M & L for 35mm thick IInd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a);
M&L for two coats of synthetic enamel paint on old steel surfaces , over a coat of red oxide over 10 cm in width or girth not other wise described complete.
S & F for Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube complete all as specified and as directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style)consisting of frame made out of MS tubes for top & bottom rail, MS frame shall be covered with heat moulded plain cover PVC "C" channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for styles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and shown on drawing in SSR Part II 2020.
S & F 125 mm Butt hinges, Medium weight, cold rolled mild steel, and fixed , Type-B-12
S & F of 200mm Aluminium anodised, barrel tower bolts of extruded section and fixed
S & F Aluminium handles, cast type, anodised of size 150 mm
S & F 300mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F UPVC window,(unplastisized poly-Vinyl Chloride) sliding windows multi-chambered and stiffened framed windows using 88mm x 52mm size sections all-round as main frames and shutters made with profile sections of size 57mm x 42mm, including the cost and fixing of 5mm thick clear float glass in shutters and stainless steel wire mesh shutters shall have well defined welded corner joints without any gaps, fixed the window unit to the existing masonry with anchor fasteners as required. The shutters shall have necessary handles and other associated fittings to facilitate smooth operation. Both the frames and the shutters shall be reinforced with GI profiles of thickness 1.25mm the entire window is covered with MS powder coated tube of size 40mm x 20mm all-round the frame the frame section, 10mm square bars horizontally placed at 120mm C/C and suitably placed vertically to avoid buckling and providing structural strength, Minimum weight shall be 10kg/Sqm and fixed to UPVC frames with suitable fasteners. The gaps between the window frames and masonry walls shall be filled with silicon or with any other suitable filler materials complete all as specified and directed. Make : Rajshri Plastiwood/Sintex/Duroplast Extrusion Pvt. Ltd
Supply only 5.5 mm thick glass fixed to Aluminium frame work complete.
S & F Aluminium , XMP wire mesh average width of aperture 1.40mm and fixed with aluminium wire staples
S & F Powder coated Aluminium grill/Deco grill for Windows , Ventilators etc
S & F stainless steel pipe 25mm dia Curtain rod for Windows, doors opening etc
S & F Fancy type CP Knobs for fixing curtain rod all as directed and specified
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed .
M & L for Plain Cement concrete 25mm thick type B-1, 1:2:4 (20mm graded aggregate) as in sub base
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc
M & L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over a screed bed of 20mm thick in cement mortar 1:4
M&L for machine cut granite mirror finished kota stone slab flooring 18-20mm thick laid & jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing as in steps/skirting /shelves over 10 mm thick rendering with CM 1:4, etc complete all as specified& directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M & L for Ist or premium or standard quality of non skid, ceramic “coloured” joint free tiles of size 400 x 400 x 6-7mm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over 15mm thick screed bed of CM 1:6 complete of item all as directed.
M & L for Ist or premium or standard quality of non skid, ceramic “coloured” joint free tiles of size 400 x 400 x 6-7mm thick, skirting etc. set and jointed in neat slurry and pointed in white or coloured cement to match for joint free over backing of 10 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces
M & L for non skid, ceramic “coloured” joint free tiles of size 300 x 300 x 6-7mm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over 15mm thick screed bed of CM 1:6 complete of item all as directed.
M&L glazed ceramic coloured tiles 300 x 450x 6-7 mm thick as in vertical surface set & jointed in neat cement slurry & pointed with coloured cement to match over 10 mm thick rendering with CM 1:3 all as specified &directed.
S&F in repairs 32mm Gun metal Globe Gate valves with iron wheel head, screwed both ends for iron pipe
S & F in repairs PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls
S & F in repairs PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls
S & F PVC (SWR) vent cowl 110mm
S & F PVC (SWR) vent cowl 75mm
PVC (SWR) bends any radius 75mm
PVC (SWR) bends any radius 110 mm
S & F in repairs Bib taps 15mm dia Fancy type Chromium Plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed
S & F in repairs two way bib cock, CP, Fancy type - 15mm dia
S & F in repairs 15mm bore dia Stop valves fancy type Chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S & F Health Faucet for 15mm dia with 1.5m long easy flex tube in Chrome finish and wall look
S & F in repairs Tubular towel rod brass chromium plated, 20mm dia, 60cm long between flanges
S&F, in repair VC Wash Hand Basin, white ,flat back, size 550x400mm excluding taps ,waste, chain and plug but including brackets incl cutting and for pinning in ends of brackets.
S & F in repair Vitreous China wash down water closet pan (pedestal pattern), white (including fixing bolts and Seat Cover)
S&F in repair PVC Flushing cistern 10 ltr capacity with inlet ball valve float and handle and 32mm bore flush pipe including bracket complete all as specified and directed.
S & F Soap dish chromium plated, fixed to plugs with chromium plated brass screws
S & F in repairs Brass chromium plated shower rose 125mm size
S & F PVC flexible connections 15mm size with PTMT nuts of length 600mm
S & F 100 mm PVC (SWR) floor trap, plain including jointing with solvent cement
S & F 75 mm PVC (SWR) floor trap, plain including jointing with solvent cement
M/L for SS chromium plated plate rack of size 600x750mm made by 1 mm thick sheet all as approved by GE.
M&L for cement concrete shelves chajja etc Type B-0 1:2:4 (12.5 mm Gde agg) and setting complete.
M&L for TMT bars of 8mm dia and cut to length bent to shape required incl cranking ,bending and binding with and incl mild steel wire annealed not less than 0.9mm dia complete
Demolition of brickwork or stone/boulder masonry built in cement mortar or cement lime mortar
M&L for half brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4
Taking down cement plaster on brick walls including racking out joints hacking for key scrubbing down with water etc complete.
M&L Repair to Beam/chajja/drop/facia, (Broken / damage) making good with PCC 1:2:4 type B1 or cement mortar 1:3, Rendering 15 mm thick with using water proofing compound , sides and soffits in cement mortar 1:4 including necessary form work wherever damaged, including re-inforcement duly welded if required . Including demolition of broken/ loose PCC or taking down old plaster height up to 8 M.
M&L for rendering cement plaster 15 mm thick on other than fair faces wall in CM 1:6 finished even and smooth without using extra cement.
M&L for rendering in two coats with first coat of 10 mm thick in CM 1:4 and second coat of 5 mm thick duly mixing water proofing compound in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement . Note: Supply only WPC shall be measured and paid separately.
Supply only Integral Water Proofing Compound (ISI marked) of approved make.
M&L for rendering cement plaster 5 mm thick on fair faces of ceiling in CM 1: 3 finished fair and even without using extra cement.
M & L for preparation of new plastered surface (internal walls) and applying two coats of Oil bound distemper over wall care putty of 1 mm thick all as specified and directed
M & L for complete removal of existing treatment on internal walls and applying two coats of Oil bound distemper over wall care putty of 1 mm thick all as specified and directed
M & L for preparation of new surface of walls and applying two coats of Exterior emulsion weather coat paint over a coat of primer over wall care putty of 1 mm thick for external surface on walls complete all as specified and as directed by the Engineer-in-Charge.
M & L for complete removal of existing treatment on walls and applying two coats of Exterior emulsion weather coat paint over a coat of primer over wall care putty of 2 mm thick for external surface on walls complete all as specified and as directed by the Engineer-in-Charge.
M & L for preparation of old surfaces and applying three coats of white wash on Ceiling
Provn of making hole in marble/granite slab of cooking platform for cooking gas pipe etc by means of drilling machine n.exc 25 mm dia all as directed by Engineer-in-Charge
M&L for hasp and staple Aluminium anodized ,incl bolt to hinge plate and fixed with screws 100 mm long.
Taking up or down 15mm bore, steel tubing and connection including cleaning for refixing or removal from site.
Taking up or down 20mm bore, steel tubing and connection including cleaning for refixing or removal from site.
S&F in repair for rotational moulded polythene water storage tank (triple layer cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR-I 1000 ltr capacity
S&F in repair 3-in-1 Contessa wall mixer can easily be wall mounted and has provision for an overhead and hand shower with 115mm long bend pipe complete all as specified and as directed.
S&F in repair 3 hole basin mixer with pop up waste assembly, fancy type and connection complete work with quarter turn fitting (IVC) complete all as specified and as directed.
M&L for ball valve high pressure of PTMT with epoxy coated Alu Rod and high density plastic ball screwed for iron pipe and fixed 20 mm bore complete all as specified.
M&L for Gun metal gate valve with iron wheel head ,screwed both ends for iron pipe and fixed 32 mm bore complete all as specified.
S&F in repair sinks with drainage board made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x160mm
S & F 18 mm thick Prelaminated MDF board, exterior grade prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with screws to timber frame work as in cupboards etc
S & F Continuous (piano) hinges, mild steel, bright finish or electro galvanised for 30 mm flaps
M&L for painting one coat of synthetic enamel paint on old wooden surfaces over a coat of pink primer of any description not otherwise described over 10 cm width or girth.
M&L preparing new wooden surfaces of any description not otherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed .
M&L for 75mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection , pavement surface finished even and smooth without using extra cement complete all as specified and directed.
S & F 32 mm outer dia, 3-layer PP-R P o l y p r o p y l e n e random copolymer) for concealed pipes SDR 7.4 (PN - 16) UV stabilised and a n t i m i c r o b i a l fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
S & F 25 mm outer dia, 3-layer PP-R P o l y p r o p y l e n e random copolymer) for concealed pipes SDR 7.4 (PN - 16) UV stabilised and a n t i m i c r o b i a l fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
S & F 16 mm outer dia, 3-layer PP-R P o l y p r o p y l e n e random copolymer) for concealed pipes SDR 7.4 (PN - 16) UV stabilised and a n t i m i c r o b i a l fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc.
M & L for Treatment of soil under existing floors using emulsion @ one litre per hole , 300 MM apart including drilling and plugging 12 MM dia holes with cement mortar 1:2 to match the existing floors.
M & L ATT at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same .
M& L for ATT along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc in apron complete.
Dismantling cast iron work of any description complete all as specified and as directed.
M&L stainless steel pipe conforming to grade 304 as in framed work such as railing, walkway etc.. and similar work including fixed in floors and wall with drilling and welding complete all as specified and as directed by the Engineer-in-Charge.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L for Boulder Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface
M & L for 100 mm thick Plain Cement concrete of type C2, 1:3:6 (40 mm graded aggregate) in subbase
M & L for Designer cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey and cement pigment in floors over a screed bed of 20mm thick in cement mortar 1:4
Taking down carefully existing aluminium conductor point wiring (light / fan / socket or power point) complete, with all fittings such as switches, socket, regulator, ceiling rose, utility light fittings and lamp holders etc and removing materials from site and making good the disturbed surfaces of walls roof and floor etc as per existing specification complete all as specified and as directed.
Taking down carefully by unscrewing from boards / outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and fan regulators etc. for reuse at site complete all as specified and as directed. (Note : To be measured only when found serviceable in all respects complete for reuse)
Material and labour for point wiring for one light controlled by 1 one way switch with 1.5 Sqmm PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable 1100 Volts grade drawn carefully through existing/New concealed conduit along with 1.5 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire, connected to earth dolly and to be terminated in and including new pressed steel sunken boxes , readily available (Having wall thickness not less than 1.22 mm for boxes upto a size of 200 mmX300 mm and beyond that the wall thickness shall be not less than 1.63 mm) concealed type with 3mm thick bakelite sheet cover for mounting switches, sockets, fan regulators etc including testing on completion complete including making good disturbed surface all as specified and as directed.
All as per Item No. 105 here-in-before but for one light point controlled by two 2 way switch all as specified and as directed.
All as per Item No. 105 here-in-before but for one E/Fan point controlled by 1 one way switch and regulator all as specified and as directed.
All as per Item No. 105 above but for one 3 pin switch socket outlet, 5 Amp on independent board all as specified and as directed.
All as per Item No. 105 here-in-before but for one switch socket outlet, 5 Amp on same board with other switches all as specified and as directed
All as per Item No. 105 here-in-before but for one16 Amp 3 & 5 pin switch socket outlet, independent with 4 Sqmm single core multi-stranded copper conductor cable (FRLS) along with 4.0 sqmm continuous PVC insulated unsheathed single core multi-stranded copper conductor (FRLS) cable for earth continuity wire all as specified and as directed.
All as per Item No. 105 here-in-before but for one bell point controlled by one bell push on the same board with other switches or independent all as specified and as directed.
M & L for XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) ISI mark with stranded aluminium conductor 1100 Volts grade, cross sectional area 35 Sqmm 3.5 Core laid in trenches/poles/ on wall all as specified and as directed.
Supply and fixing socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal all as specified and as directed.
Supply and fixing Metal clad plug & AC socket combination 20A 2P +E, 230V AC all as specified and as directed.
Supply and fixing switch piano flush button single pole one way 5 amps all as specified and as directed.
Fixing only switch flush button single pole one way 5 amp all as specified and as directed. (Note : Material obtained from item No 104 here in before shall be reused)
S&F switch flush type, single pole Two way 5 Amps 230 volts all as specified and as directed.
Supply and fixing socket combination 2 in 1 3 pin 5 amp flush type universal all as specified and as directed.
Fixing only switch socket outlet 5 amp flush type all as specified and as directed. (Note : Material obtained from item No 104 here in before shall be reused)
Supply and fixing ceiling rose surface bakelite three terminals all as specified and as directed.
Fixing only ceiling rose surface bakelite three terminals all as specified and as directed. (Note : Material obtained from item No 104 here in before shall be reused)
Supply and fixing fan regulator electronic deluxe rotary step type all as specified and as directed.
Fixing only fan regulator any type all as specified and as directed. (Note : Material obtained from item No 104 here in before shall be reused)
Material and labour for bell ding dong AC 230 volt single pole all as specified and as directed
Supply and fixing bell push, flush type 6 amps all as specified and as directed.
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , Triple Pole and Neutral (TPN), suitable for 4 way, Double door 415 Volts all as specified and as directed .
Supply and fixing sheet metal enclosure for MCB, DBs, phosphatised, Powder coated , single pole and neutral (SPN) 240 Volt , double door, suitable for 8 way with din rail earth and neutral bar all as specified and as directed.
Supply and fixing MCB Four Pole (FP) C curve 10kA breaking capacity of 63 amps, 415 Volts complete all as specified and as directed.
Supply and fixing MCB Single Pole (SP) C curve 10kA breaking capacity of 6 to 32 amps, 240 Volts in proper position all as specified and as directed.
S&F in proper position MCB Double Pole of capacity up to 40 amps, 240 Volts c-series with 10kA breaking capacity all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type energy efficient saving LED BATTEN LIGHT 10 W,230 V,50 HZ, slim integrated design easy install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
Supply and fixing indoor luminaire decorative batten for wall/ceiling mounting box type Extruded aluminium housing ,PC Diffuser, energy efficient saving LED BATTEN LIGHT 20W,230 V,50 HZ, slim integrated design easy install incl twin twisted copper conductor flexible wire from ceiling rose to connector all as specified and as directed.
S&F 10 W LED decorative CITY 3 wall/surface mounting polycarbonate body suitable for retrofit LED Lamp Base B-22 incl lamp ,all as specified and as directed Make Havells Cat no LHDL06160099 or equivalent as approved by GE.
Supply and fixing LED mirror light fittings 07 W, 230 V, 50 HZ suitable for indoor and outdoor applications complete all as specified and as directed.
Supply and fixing LED bulk head fittings 10 W,230 V,50 HZ suitable for indoor and outdoor applications complete all as specified and as directed. Make Surya Cat No SLE BH 10 W or equivalent as approved by GE.
Supply and fixing on wall security LED light luminaire fitting 1X25 W and including cable for connection from celling rose with 1.5 Sqmm PVC insulated stranded copper conductor (FRLS) cable including 25 mm GI bracket medium grade 1m long bent to shape including bolt, nut, washer, clamp etc all as specified and as directed by the Engineer-in-charge.
Taking down carefully ceiling fan any sweep and any make after disconnecting the electrical connection, dismantling the blades and removing fan incl blades for safe custody for reuse and re-assembling the fan complete and refixing the fan in same position including all electrical connection all as specified and as directed.
Material and labour for taking out and removing burnt copper winding, cleaning the armature, rewinding the fan armature for 1200mm sweep fan with new super enamelled copper wire of existing gauge including supply and fixing necessary insulating materials etc and varnishing with approved grade of insulation varnish and heating up and testing all as specified and as directed.
Supply only bearing No.6201/6202 for ceiling /Exhaust fan
Supply only fan condenser upto 2.5 mfd.
Material and labour for painting of ceiling fans complete of any sweep/make with one coat of first quality synthetic enamel paint of approved tint by spray including preparation of old painted surface and removing all dust, oil mark etc and filling cavities with filler materials, and writing serial / MES number as specified (with paint of black colour with each letters/figures in Block of height n.exc2 cm ) complete all as specified and as directed.
S&F Exhaust fan wall mount type 300 mm sweep metal body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
S&F Exhaust fan wall mount type 250 mm sweep PVC body , single phase with louver shutter and connecting up including provision of hold fasts for fixing fan and louver shutter with cutting of hole and necessary PCC(1:3:6) all as specified and as directed.
Taking down existing unserviceable MS box after disconnecting all electric connection and Supply and fixing factory made enclosure box for mounting meter panel of size 0.6x0.6x0.2m indoor and wall mounting type made of 2mm thick MS sheet with front side openable with two nos hinged type door with locking arrangement and danger notice board, dust and vermin proof including providing all necessary electrical connection by supply and fixing single core multi stranded copper conductor FRLS cable of appropriate size, making circular hole for cable entry and exit including cable gland of required size, incl two coat of powder coated paint to out side surface and two coat of synthetic enamel paint to inside surface over a coat of red oxide , and making good the disturbed surfaces or wall etc complete incl necessary nut,bolt, washers for mounting on wall and making provisions for mounting electric meters and MCBs all as specified and as directed.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of FRLS cable etc and getting out in Soft/loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed
Material and labour for sand cushioning for protection of underground FRLS cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid)
Supply and lay bricks common burnt clay building bricks sub-class B of size 230x113x75 complete all as directed by Engr-in-Charge.
M&L for Drilling of hole horizontally 80/40 mm dia bellow the road for providing casing pipe of cable protection by using mechanical/hand drill
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting for protection of FRLS cable, laid in trenches/wall/floor incl necessary clamp, bolt/nut if any all as specified and as directed. Note: Excavation , earth work shall be measured and paid separately
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 4.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 4.0 sqmm, single core, as earth continuity wire all as specified and as directed. (NOTE: 3 runs of 4.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
Material and labour for sub main wiring with two single core PVC insulated un-sheathed cable with multi-stranded copper conductor of 6.0 sq mm size and drawing into and including concealed PVC conduit of 25 mm dia with earthing cable of PVC insulated un-sheathed stranded copper conductor of size 6.0 sqmm, single core, as earth continuity wire all as specified and as directed. (NOTE: 3 runs of 6.0 Sqmm cable and one run of PVC concealed conduit 25mm dia will be measured as one unit i.e. RM)
M&L for Earthing complete with 3 m CI pipe 80 mm dia with flanged ends, centrifugally cast, class A, in any length, joints with suitable stainless steel nuts and bolts and sufficient slot up to 2.5mtrs length buried directly and preferably vertically in ground with top flanged ended 2.5mtrs below ground label welded/connected with GI strip 32×6mm size on the top edge of the flange to bottom edge of the flanged for earthing including filling the pit with charcoal common salt surrounding the earth pipe including drilling 400 mm dia bore in any strata of soil to lower the CI pipe complete including necessary excavation and earth work PCC (1:3:6) type C-1 with 50 mm thick pre cast RCC (1:2:4) type B-1 cover slab and necessary testing on completion complete all as specified and as directed.
N V S S K N SIVA PRASAD
VASANTHA NAIDU ASSOCIATES
POTHINA SAMBAMURTHY
SSV CONSTRUCTIONS
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
SRI RAJA RAJESWARI ENTERPRISES
SWATHI CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .