| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.4 LAccepted-AOC | ₹21.4 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹22.5 L+₹1.1 L (4.97%)Rejected-Finance POST MISAMARI DIST SONITPUR ASSAM 784 506 | SONITPUR | ASSAM | 784506 | ₹22.5 L+₹1.1 L (4.97%) | L2 | Rejected-Finance HIGH BID VALUE |
| 3 | L3₹22.9 L+₹1.4 L (6.74%)Rejected-Finance BISHNU RAVA PATH PO PS TEZPUR DIST SONITPUR ASSAM | TEZPUR | SONITPUR | ASSAM | ₹22.9 L+₹1.4 L (6.74%) | L3 | Rejected-Finance HIGH BID VALUE |
| 4 | L4₹23.6 L+₹2.2 L (10.2%)Rejected-Finance | ₹23.6 L+₹2.2 L (10.2%) | L4 | Rejected-Finance HIGH BID VALUE |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
2 Nov 2023, 6:00 pmClosed
COL SUNIL PILLAI
HQ CWE TENGA PIN-900194 C/o 99 APO
PROVN OF GATE WITH SENTRY POST NEAR EAGLE CHOWK GOVIND NAGAR BUS STOP IDSR MISSAMARI MIL STN PROVN OF CHAIN LINK FENCING AND PROVN OF QTY 10 NEW EARTH PITS WITH CHAMBER AND COVER AT TOR COMPLEX AT CERTAIN LOCATIONS OF GE MISSAMARI
2023_MES_621779_1
8393/E8
Open Tender
Civil Works
Item Rate
180 days
GE MISSAMARI
D (a) (i)
8 documents required · 8 mandatory
₹500
Yes
GE MISSAMARI
₹54,000
Yes
19 Dec 2023
5 Oct 2023
9 Nov 2023
5 Oct 2023
2 Nov 2023
19 Oct 2023
Amount
Surface dressing in soft loose soil n exc 15 cm deep and getting out.
Excavating in trenches n.exe. 1.5 m width and n.exe. 1.5 m in depth for foundation in soft/loose soil & getting out complete all as specified and as directedas specified.
Returning filling in , including spreading,levelling,watering & well ramming in layers not exc 25 cm complete all as specified and as directedas specified.
Removing excavated material n exc 50 m & depositing where directed at a level n exc 1.5 m complete all as specified and as directedas specified.
M&L cement concrete with PCC type D2 1:4:8 using 40mm graded aggregate as in foundation complete all as specified and as directedas specified.
M&L for brick work with burnt old size bricks built in cement mortar 1:6 straight or curved on plan exceeding 6mtr mean radius complete all as specified and as directedas specified.
M&L40 mm thick Damp proof course to horizontal or vertical surfaces including necessary form work in cement concrete 1:2:4 type B-0 (Using 12.5 mm graded stone aggregate) mixed with WPC ( WPC shall be measured & paid separately) complete all as specified and as directedas specified.
M&L rendering 15mm thick on other than fair faces of brick or concrete Surfaces in cement mortar 1:6 finished even and smooth complete all as specified and as directedas specified.
M&L for 20mm (10 +10) thick plaster on fair faces of brick work or concrete surface in cm (1:4) with wpc @2% by weight face of conc work to wall surface and the surface is finished even and smooth without using extra cement complete all as specified and as directedas specified.
Supply only integral WPC complete all as specified and as directedas specified.
M&L for 75 mm thick pcc 1:3:6 type C2 using 40mm graded aggregate as in plinth course as directed by engineer in charge.
M&L Sand filling under floors or in foundations including watering and conosoldiation complete all as specified and as directedas specified.
M&L for brocken stone or boulders of hardcore of gauge n exc 63 mm deposited, spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and as directedas specified.
M&L for 100mm thick PCC type B2 1:2:4 using (40mm gradded aggregate) as in floor incl finishing cement concrete surface even and smooth using extra cement complete all as specified and as directedas specified.
S&F pre painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directedas specified.
S&F pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F roof trusses (framed) trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (beam tee, angle, channel or flat sections) including clits etc confoRming to Fe-410-0 or Fe-310-0.
M&L three coat of white wash on wall surface including preparation of surface..
M&L two coats of cement base paint over a coat of primer on wall surface including preparation of surface..
M&l Painting two coats of synthetic enamel paint over a coat of red oxide primer to new steel Surfaces of any description, not otherwise described, over 10cm width or girth.
S & F MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, quality confirming to Fe-290 (Gde-E-165) complete all as specified.
M&L Cement Concrete 1:3:6 type C2 (40mm graded aggregate) in Foundations, Filling and Mass Concrete including use and waste Formwork as ordered/required at Site, complete all as specified and as directed.
S & F MS framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, quality confirming to Fe-290 (Gde-E-165) complete all as specified.
M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 or Fe -330, with and incl necessary nut and bolts of 12mm dia of reqd length complete all as specified and as directedas specified.
Supply only chain link MS galvanised any mesh size or type complete all as specified.
Fixing only chain link fencing including line wire, any mesh, size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed.
M&L TMT Bars 10mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia, complete all as specified and as directed.
S & Fix Galvanised 2 strand, steel barbed wire, 2.24mm dia barbed with 2mm dia barbs straining and fixing to any type of standard rails straining bolts, includigng, securing or tying at crossings with and provision of steel wire, staples or steel pins, etc complete all as specified and as directedas specified.
S&F Maintenance free chemical Earthing system complete with 03 Nos of Copper pipe of 100 mm dia with UL 467 approved copper bonded earth rods 17 mm dia 3000mm long electrode dipped fully in earth enhancing chemical compound buried in ground to bore holes 100 mm dia vertically to a depth not less 3.5 mtr deep below ground level with top edge of earth electrode at a depth not less than 500 mm below normal ground level, interconnected each other parallelely in Triangle Shape horizontally along with provision of copper busbar of size 32 mm x 6mm for inter connection of tripodsand provision of copper strip of length 7 meters from the tripod intersections of size 32mm X6mm including 45 x3 kg (Minimum) NABL Lab certified back fill earth enhancing compound for filling 3 x bore holes with soil mixed ,so as to achieve earth resistance below 1 Ohms including necessary excavation and earth work and Provn of PCC Chamber in PCC (1.3:6) type C1 (using 20 mm graded stone aggregate) with pit cover of 300 mm x 300 mm made of Cast Iron for each earthing complete all as Specified and directed. Note :- 1.Copper earth Strip upto 7 meters of length from earth pit to be included in the quoted rates .Copper earth strip beyond 7 meters will be paid and measured separately 2. All copper strip joints should be brazed with copper electrodes . Copper Nut & Bolt system for opening and refixing of strip should be done at Test point terminal block.
S& F of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit /pipe or fixed to poles or any other indicated situation for loop earthing etc as required with 32 x 6mm copper strip duly fixed on insulators on walls / ceilings complete all as specified and directed by Engr-in Charge. (Note :- Al copper strip joints should be brazed with copper electrodes . Necessay rates to be included in quoted rates).
S & F Test point terminal block made of gun metal or Phosphorus bronze size 75 x 75 x 25 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw complete all as specified and as directed.
S&F GI Pipe of 40 mm Dia, ISI Marked , light grade to cover the copper strip (32 mm x 6mm) complete all as specified and as directed as specified.
Supply and fix PVC Junction box of size 217X253X115 with mounting plates fixed on insulators on walls / ceiling suitable for fixing of Test Point terminal block complete all as specified and directed bt Engr-in charge Make - Cat No. KG 9003 of Hensel or Equivalent in Syntax or Equivalent
RC Madan
M/S B.B. Singh Contractor
M/S Himalayan Trading Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .