The Superintending Engineer, PWD Buildings Central
O/o Superintending Engineer, PWD Buildings Central Circle Thrissur
Construction of school building for Government L.P. School Akaparambu Ernakulam General Civil Work
2026_PWD_875611_1
PWD/BLDG/TR/16357/2024_5_1_1/1
Open Tender
Civil Works - Buildings
Item Rate
540 days
Akaparambu
Please refer Tender documents
12 documents required · 12 mandatory
₹6,508
Yes
₹50,000
Yes
3 Oct 2026
3 Oct 2026
16 Oct 2026
3 Oct 2026
14 Oct 2026
3 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Pile foundation | |||||
| 1.001 | 50.2.3.1:Pumping or Bailing out water and removing slush etc by using pump set including cost of labour, oil hire charges of pumpset, etc complete | 138 | hour | - | - |
| 1.002 | 2.31:Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared | 315 | sqm | - | - |
| 1.003 | OD114588/2026-2027:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).500 mm dia piles | 382.95 | metre | - | - |
| 1.004 | OD114578/2026-2027:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap).600 mm dia piles | 284.75 | metre | - | - |
| 1.005 | 56.7:Conducting standard penetration test in bore hole at any depth. | 6 | each | - | - |
| 1.006 | OD20679/2026-2027:Vertical load testing (INITIAL) of piles in accordance with IS : 2911(Part -IV) including
installation of loading platform and preparation of pile head or construction of test cap and
dismantling of test cap after test etc. compete as per specification & above 50MT and up to 65
MT -500mm Pile-Test load should be 2.5 times the pile load capacity=2.5*65=163T | 1 | per test | - | - |
| 1.007 | OD20500/2026-2027:Vertical load testing (INITIAL) of piles in accordance with IS : 2911(Part -IV) including
installation of loading platform and preparation of pile head or construction of test cap and
dismantling of test cap after test etc. compete as per specification & above 50MT and up to 90
MT-600 mm Pile-Test Load should be 2.5 times the pile load capacity=2.5*90=225T | 1 | per test | - | - |
| 1.008 | OD20690/2026-2027:Vertical load testing of piles in accordance with IS : 2911(Part-IV) including installation of
loading platform and preparation of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single
pile above 50 tonne and upto 65 tonne capacity .Routine test.-500mm Dia Pile-Test load
shouldbe 1.5 times the pile load capacity 1.5*65=98T | 1 | per test | - | - |
| 1.009 | OD20685/2026-2027:Vertical load testing of piles in accordance with IS : 2911(Part-IV) including installation of
loading platform and preparation of pile head or construction of test cap and dismantling of test
cap after test etc. complete as per specification & the direction of engineer -in-Charge. Single
pile above 50 tonne and upto 90 tonne capacity .Routine test.-600MM Dia Pile-Test Load
should be 1.5times the pile load capacity=1.5*90=135 T | 1 | per test | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Tendernotice_1.pdf
PDF • 0.05 MB
sbd.pdf
Tender Documents • 11.46 MB
ITB.pdf
Tender Documents • 0.48 MB
nit.pdf
Tender Documents • 0.03 MB
afdt.pdf
Tender Documents • 0.03 MB
ept.pdf
Tender Documents • 0.08 MB
integrity.pdf
Tender Documents • 0.01 MB
BOQ_1486611.xls
BOQ • 0.36 MB
PG.pdf
Tender Documents • 0.32 MB
FormTender.pdf
Tender Documents • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .