GE BARRACKPORE
Office of the GE BARRACKPORE
SPECIAL REPAIR TO CERTAIN B/R AND E/M SERVICES OF CERTAIN PUMP HOUSES INCLUDING REPAIR/REPLACEMENT OF PUMPS, PANELS AND SUBMERSIBLE PUMPS AT KANCHRAPARA MIL STN UNDER GE BARRACKPORE
2026_MES_793542_1
8328/E8
Open Tender
Civil Works
Item Rate
180 days
BARRACKPORE
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹500
GE BARRACKPORE
₹66,520
Yes
12 Oct 2026
12 Oct 2026
4 Nov 2026
12 Oct 2026
2 Nov 2026
26 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling of asbestos cement sheet (corrugated or semi corrugated etc) as in roof covering complete all as specified and as directed. | 30 | Sqm | - | - |
| 2 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and as directed. | 25 | Sqm | - | - |
| 3 | M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and as directed.
Note: To be executed for provision of ridges and hips. | 5 | Sqm | - | - |
| 4 | S&F 4mm thick Non asbestos fiber cement building boards (E-board) inserted to Aluminium framework using screws with powder coated Anodised aluminium snap grid frame work for false ceiling, Size of grid 605 x 605mm using Main/Cross Bulbed tees - Tapered head (Web : 25mm Flange : 38mm) of weight not less than 0.249 kg/m and Equal angle of size 25mm of weight and not less than 0.196 kg/m, for false ceiling, flat or sloping fixed or laid with hangers 6 mm dia GI (n-exc 1200 mm in length apart) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60 mm long and expansion hold fasteners 12.5 mm dia 40 mm long including dismantling of old ceiling of any description complete all as specified and as directed. | 25 | Sqm | - | - |
| 5 | Taking down all existing roof treatment and demolition of cement concrete padding/levelling course (any thickness as available in site) including wire brushing and cleaning loose dust etc from surfaces of RCC roof including flashing and junction of parapet complete all as specified and as directed. | 40 | Sqm | - | - |
| 6 | M&L for preparation of RCC roof surface or wall & floor of sunken slab by cleaning the entire roof with Pressure water jet to remove the unwanted dust, loose material or any other material which may impair adhesion of the material. Surface must be cleaned and dried properly so that any cracks on the substrate can be visible. Concrete substrate to be cleaned up to exposed sound concrete cover, remove dust, laitance etc, which may impair adhesion of the material. All surface cracks up to 1-2 mm wide should be filled with single component cold applied elastomeric waterproofing coating (Dr. Fixit Roof Seal Ultra or equivalent) using a brush and adding a coat on the slab on both sides of the crack, up to a distance of 100 mm around it. Cracks more than 1-2 mm should be widen by making V-groove and repaired with PMM (Polymer Modified Mortar) using Dr. Fixit Pidicrete URP or equivalent 10% by weight of cement complete all as specified and as directed.
Note :
(i) Finished surface shall be as per satisfaction of Engr-in-Charge.
(ii) All cracks shall be prepared and checked by Engr-in-Charge before and after treatment for the satisfaction and rates quoted shall be including the quantum of cracks in proposed surfaces which shall be checked on ground by the contractor before quoting bid.
(iii) No additional amount shall be claimed further for repairing cracks.
(iv) Entire application shall be carried out by trained certified manufacturer applicator only. | 40 | Sqm | - | - |
| 7 | M&L for 40mm thick PCC 1:2:4, type B0 (using 12.5mm size graded crushed stone aggregate) as levelling course, padding on chajjas, etc including angular moulding at junction upto 10cm height mixed with WPC as per manufacturer's instruction, applied over prepared surfaces complete all as specified and directed.
Note :
(i) WPC shall be measured and paid separately as supply only.
(ii) PCC shall be laid to achieve true slope towards the drain/weep holes. | 40 | Sqm | - | - |
| 8 | Supply only Elastomeric Hydrophobic Powder/admixture (EHP) powder for cement plaster and concrete complete all as specified and directed. | 15 | Kg | - | - |
| 9 | M&L for single component cold applied elastomeric waterproofing coating (Dr. Fixit Roof Seal Ultra or equivalent) on in-accessible/accessible roof or wall & floor of sunken slab based on synthetic resin emulsion, tough yet extremely flexible coating that can be efficiently applied by roller or squeegee having following important features :
(i) High film build up provides excellent water resistance. (ii) Excellent flexibility and elongation properties - can easily accommodate all normal building movements.
(iii) Can be applied to complex shapes to form a seamless and highly durable water proofing coating. (iv) Adheres firmly to most of building surfaces incl both horizontal and vertical surfaces of parapet, etc. (v) Suitable consistency for easy application by brush, roller or squeegee.
Single component cold applied elastomeric waterproofing coating (Dr. Fixit Roof Seal Ultra or equivalent) shall be applied by sprinkling some water over the roof just before application of 1st coat @ 0.75 ltrs/Sqm uniformly over the entire flat surface and vertical parapets including reinforcing fiber (45 gsm Glass fiber mesh) and allow for drying for 12 hrs and 2nd coat @ 0.75 ltrs/Sqm shall be applied (perpendicular direction of 1st coat as per manufacturer's instruction) on dried 1st coat complete all as specified.
Note :
(i) Entire application shall be carried out by TRAINED CERTIFIED MANUFACTURER'S APPLICATOR only. (ii) Waterproofing treatment shall cover min 10 yrs WARRENTY by the applicator and Contractor. (iii) Quoted rates shall include WATER PONDING TEST : After full drying of second coat for at least 72 hrs, a water ponding test can be performed by filling water on the terrace by carefully blocking all the down take drain outlets without damaging the coating. The test shall be carried out for 48 hrs by filling water up to 50 mm level. Observe for leakages, if any, and then remove the water and allow the coating to dry completely for handing over of site.
(iv) Application shall be restricted in open sunlight having temperature above 35°C. | 40 | Sqm | - | - |
| 10 | Cutting/Demolition/dismantling of loose/damage/disintegrated concrete including plaster of any description and in any position from RCC structures like chajja, fins, roof/ceiling, louvers, parapet, column, beam, lintel, etc using manual chipping tools/breakers without disturbing stability of structure with necessary scaffolding where required including cutting reinforcement to facilitate demolition/dismantling complete and dispose off debris outside MoD land complete all as specified and as directed. | 1 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tenderdoc_8328.pdf
Tender Documents • 1.44 MB
BOQ_889920.xls
BOQ • 0.69 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .