Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹54.9 CrAccepted-AOC | ₹54.9 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹58.8 Cr+₹3.9 Cr (7.18%)Rejected-AOC PO BIRLA VIKAS PO BIRLA VIKAS SATNA MADHYA PRADESH 485005 | SATNA | MADHYA PRADESH | 485005 | ₹58.8 Cr+₹3.9 Cr (7.18%) | L2 | Rejected-AOC L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Techno Commercial Non Responsive |
| Sl No | Description | Qty | Unit | UNIVERSAL CABLES LIMITED L2 | Jyona Power Limited L1 |
|---|---|---|---|---|---|
| 1.00Price Schedule-A | |||||
| 2.00Supply for Termination of 220 kV Jhajra- Sherpur Line from AP 16 to cable termination point near at 400 kV Substation Sherpur (PGCIL) Dehradun" with Multicircuit tower | |||||
| 3.00Design | |||||
| 4.00 | Designing of 220 kV Multi circuit tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | 7,50,000 ₹7,50,000 | 6,85,000 ₹6,85,000 Lowest |
| 5.00 | Designing of 220 kV Multi circuit tower (i.e. 4 circuits) suitable for (15 deg-30deg) along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | 7,50,000 ₹7,50,000 | 6,85,000 ₹6,85,000 Lowest |
| 6.00 | Designing of 220 kV Cable ternination Multi Circuit type tower (i.e. 4 circuits) along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | 7,50,000 ₹7,50,000 | 6,85,000 ₹6,85,000 Lowest |
| 7.00 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Multi Circuit type tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with their extensions. | 1 | Nos. | 3,00,000 ₹3,00,000 | 2,75,000 ₹2,75,000 Lowest |
| 8.00 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Cable ternination Multi Circuit type tower (i.e. 4 circuits) along with their extensions. | 1 | Nos. | 3,00,000 ₹3,00,000 | 2,75,000 ₹2,75,000 Lowest |
| 9.00 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Multi Circuit type tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with their extensions. | 1 | Nos. | 3,00,000 ₹3,00,000 | 2,75,000 ₹2,75,000 Lowest |
| 10.00Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of towers with cleat including Nuts & Bolt. | |||||
Tender Value
Refer Docs
EMD Value
₹78.9 L
Closing Date
5 Jun 2025, 3:30 pmClosed
SE C and P 2
SE C and P 2 PTCUL Mjara Dehradun
Termination of the LILO of 220 kV Sherpur Jhajra at 120 MW Vyasi HEP UJVNL for direct at 400 kV substation Sherpur PGCIL with a line length of apx 2.5 km partially O H approx. 1.5 Km with multi-circuit towers and partially with UG apx length 1 Km
2025_PTCU4_82688_1
PTCUL/CandP-II/TL-01/2025-2026
Open Tender
Electrical Works
Item Rate
900 days
Dehradun
Please refer Tender Document and NIT
4 documents required · 4 mandatory
₹29,500
Yes
MD PTCUL
₹78.9 L
Yes
Dehradun
16 Jun 2026
11 Apr 2025
6 Jun 2025
11 Apr 2025
5 Jun 2025
1 May 2025
24 Apr 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Price Schedule-A | - | - | - | - |
| 2 | Supply for Termination of 220 kV Jhajra- Sherpur Line from AP 16 to cable termination point near at 400 kV Substation Sherpur (PGCIL) Dehradun" with Multicircuit tower | - | - | - | - |
| 3 | Design | - | - | - | - |
| 4 | Designing of 220 kV Multi circuit tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | - | - |
| 5 | Designing of 220 kV Multi circuit tower (i.e. 4 circuits) suitable for (15 deg-30deg) along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | - | - |
| 6 | Designing of 220 kV Cable ternination Multi Circuit type tower (i.e. 4 circuits) along with Body extensions (i.e. +3M, +6M, +9M & 12M), normal stub & raised chimney stubs with Cleat, Bolts, Nuts & Washers, etc. as finalized by PTCUL. | 1 | Nos. | - | - |
| 7 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Multi Circuit type tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with their extensions. | 1 | Nos. | - | - |
| 8 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Cable ternination Multi Circuit type tower (i.e. 4 circuits) along with their extensions. | 1 | Nos. | - | - |
| 9 | Designing of Normal and Raised chimney RCC type foundations (Dry, FS and PS soil) useable for 220 kV Multi Circuit type tower (i.e. 4 circuits) suitable for (30 deg-60deg)/dead end type tower along with their extensions. | 1 | Nos. | - | - |
| 10 | Fabrication, Galvanizing & Supply of Normal Stub/Raised Chimney Stub for various type of towers with cleat including Nuts & Bolt. | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.20 MB
Tenderdocument.pdf
Tender Documents • 0.45 MB
BOQ_2.xls
BOQ • 0.38 MB
Tenderdocument_2.pdf
Tender Documents • 3.31 MB
Tenderdocument_3.pdf
Tender Documents • 0.85 MB
Tenderdocument_4.pdf
Tender Documents • 12.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .