Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.7 LAdmitted-Finance | -55.55% | ₹2.7 L | L1 | Admitted-Finance |
| 2 | L2₹4.0 LAdmitted-Finance | -33.60% | ₹4.0 L | L2 | Admitted-Finance |
| 3 | L3₹4.8 LAdmitted-Finance | -21.00% | ₹4.8 L | L3 | Admitted-Finance |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
13 Feb 2026, 6:00 pmClosed
EXECUTIVE ENGINEER,
KDA KOTA
Operation, Maintenance and Security of Lights in Seven Wonders Park
2026_UITKo_535150_1
34/2025-26 (23)
Open Tender
Electrical Works
365 days
KOTA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Online Through SSO Portal
₹12,000
Yes
20 Feb 2026
4 Feb 2026
16 Feb 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
Operation, Maintenance and Security of All Typee Of LED Street Light System With Fixtures and Perform Following Work.(i)Maintain power supply (underground and overhead) from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole to led light.(ii)Repair , Rectification, Replacement of defective component of the Existing Led light or entire led light if required so to run led light system.(iii)Replacement of old led light with new led light if led found broken/damage/stolen.(iv)Replacement of damage or burnt cable/overhead line/fuse box with new cable/overhead line/fuse box from from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole junction in supervision of engineer for this work payment shall be extra.(v)Repair of damage cable and overhead line from kedl/jvvnl energy meter to auto on off pannel to feeder piller to pcc/tubular pole.(vi)Replacement and repair of damage /burnt /stolen cable , wire or jumper from junction box to light and pcc pole to light .(vii)Operation maintenance and security of auto on off pannel installed by contractor as well as exist old pannel . If any part of pannel found defective/burnt/ stolen/damage contractor have to replace it with new parts and run the led system properly( 279 kda led* 12 month =3348 Nos. )
Operation , Maintenance and security of all street lights system (without light fixtures ) and perform following work 1. Maintain the power supply from LT line to meter panel to Auto ON-OFF timer panel to feeder pillar to fuse box/junction box. 2. For overhead lines supply should be maintain from LT line to meter panel to auto on/off panel to street light fixtures. 3. Replacement of damage cable of any size. 4. Replacement of damage contactor and auto on/off timer. 5. Replacement of damage MCB, MCCB, HRC fuse of any rating. 6. Replacement of damage fuse box/junction box. 7. replacement of damage overhead line road light conductor .(285 lights*12 month)
Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4 core*10 sqmm
3.5 core*25 sqm
Providing and fixing of IP 65 protected Polycarbonate / Polysterene fuse box moulded with inside knock outs of following size with hinged cover, transparent window, PU gasket, locking arrangement, duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nut and bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 / 16.0 sq.mm heavy duty connector, earth terminal, complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 125 mm X 200 mm X 122 mm
P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 50 mm
Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Single pole MCB (With B/C curve tripping Characteristics). 6 A to 32 A rating
Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR LT cross arm 600 mm long with clamp
SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% Icu. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 3 pole MCCB With Thermal Magnetic release. up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting,
Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 3 pole Power contactors with following AC 3 Rating. 80 Amp
Supply & fabrication steel structure with MS channel / angle / joist / ISMB / sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/Embossing/Screen printing on die cast housing to allow traceability/authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . High Power LED Flood Light Minimum lumen output 10000 lm
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.38 MB
CONDITIONS_E_34_23.pdf
Tender Documents • 0.55 MB
BOQ_953482.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid