| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing of Split Type Hi-Wall 1.00 TR (rated cooling capacity should not be less than 3000 kcal/hr or 12000 BTU/hr or 3500 W) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants), suitable for wall mounting, conforming to IS: 1391 (Part-II) specifications (evaporator and condenser coils shall be of pure copper), having not less than 3 (Three) Star Rating (latest applicable standard), operating on single-phase 230 Volt, 50 Hz AC supply, including supply of 3.0 m copper refrigerant piping (both suction and liquid lines), 3.0 m of 4 (four)-core electrical connecting cable, remote control unit including batteries, 16 Amp power top/plug, etc., complete. The unit shall be capable of performing: (a) cooling, (b) dehumidifying, (c) air circulation, and (d) air filtering, complete as directed by the Engineer-in-Charge. | 2 | No | - | - |
| 2 | Providing of Split type Hi wall 2.00 TR (rated cooling capacity should not be less than 6000 kcal/hr or 24000 BTU/hr or 7000 w) split AC machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391(part-II) specification (evaporator & condenser must be of pure copper) not less than 3(Three) Star rating (latest Standard) operates on single phase 230 volt, 50 HZ, AC Supply including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4(four) core electrical connecting cable, remote control unit including batteries, 16 amps power TOP etc complete, capable of performing a) cooling b) dehumidifying c) Air circulation d) filtering as per direction of the Engineer-in-Charge. | 10 | Nos | - | - |
| 3 | Providing of Split type Hi-wall 1.5 TR (rated cooling capacity not less than (4500 Kcal/ hr or 18000 BTU/hr or 5250 KW) split A.C. Machine with Inverter Compressor technolgy operating on non-CFC refrigerant (R 410A/R-32/equiva lent refrigerants) suitable for wall mounting Conforming to Is 1391 (part -ii) specification (Evaporator & Condenser must be of pure copper ), not less than 3 (Three) Star rating(latest Standard) operate on Single phase 230 volts , 50Hz, AC Supply including supply of 3.00 mtr copper pipe ( both for suction & liquid line ) 3.00 m 4(four) core electrical connection cable,remote control unit in/c batteries etc complete capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. | 10 | Nos | - | - |
| 4 | Standard installation of 1.0 TR/ 1.5 TR & 2.00 TR capacity High Wall Split type Air Conditioner in/c providing & fitting fixing of electrical 16 amp industrial Top & socket for indoor units, repairing of drilled wall by cement mortar, painting In/c necessary insulation of copper pipes etc. complete as per direction of the Engineer-in-Charge. | 22 | Nos | - | - |
| 5 | Fabrication of M.S. platform for placement of condensing unit by using M.S. angle of base plate as per manufacturer standard design, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge. | 22 | Nos | - | - |
| 6 | Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1 TR ,1.5 TR & 2 TR AC) beyond the standard length as per direction of the Engineer-in-Charge. | 72 | Mtr | - | - |
| 7 | Providing and connecting Electric Control cables between MCB to indoor/outdoor. 3C X 2.5 Sq. Mm Copper Cable. | 15 | Mtr | - | - |
| 8 | Providing & Fitting fixing of best quality 1 inch or 25 mm dia UPVC pipe including necessary clamping for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge. | 100 | Mtr | - | - |
| 9 | Providing of Vertical split AC unit of cooling capacity not less than 13000 watt (±10% variation) equivalent to approximately 46,000 BTU/hr (±10%) with hermitically sealed compressor operating on R22 / R-410A / non-CFC equivalent refrigerants, suitable for floor mounting, suitable for operation on 3 Phase AC supply capable of performing A) Cooling, B) Dehumidify, C) Air circulation, D) Filtering, etc., complete as per direction of Engineer-in-Charge. | 2 | Job | - | - |
| 10 | Installation and commissioning of vertical split AC unit with vaccumising, nitrogen pressure testing, first charge of refrigerant including providing Refrigerent & cable connection from MCB to Outdoor/indoor etc. (upto 3mtr) and necessary cement plastering of holes complete as per direction of the Engineer in Charge. | 2 | Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.09 MB
DNIeT.pdf
Tender Documents • 2.92 MB
BOQ_78386.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .