| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹43.0 L+₹3.6 L (9.13%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹43.1 L+₹3.7 L (9.42%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹43.5 L+₹4.1 L (10.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹43.5 L+₹4.1 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹38.8 L
EMD Value
₹77,660
Closing Date
18 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPL REPAIR TO BLDG NO. 121 MD ACCN OFFRS AT BGTC AT BARRACKPORE UNDER GE BARRACKPORE
2023_MES_620901_1
8854/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹77,660
Yes
31 Oct 2023
27 Sept 2023
20 Oct 2023
27 Sept 2023
18 Oct 2023
11 Oct 2023
Amount
PART-I Taking down chowkats with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed. (Note for Item No. 1.00 & 2.00 - Rate shall be deemed to be include for cutting holes/demolition of masionry walls etc for taking down chowkats and making good the damaged surfaces).
Taking down of shutter of any description exceeding 1 Sqm but not exceeding 2.0 Sqm each complete all as specified and directed.
Taking down of shutter of any description not exceeding 1 Sqm each complete all as specified and directed.
Taking down of shutters of any description exceeding 1 Sqm but not exceeding 2 Sqm each and refixing in same opening after easing and adjusting completed all as specified and directed.
Providing formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
S&F of factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing as mentioned in SSR Part-II (2020), Section 8, Page No. 178 complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification & drawing as mentioned in SSR Part-II (2020), Section 8, Page No.174 complete all as specified and directed.
S&F of second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints etc complete all as specified and directed.
S&F of 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&Fof 35mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made) for doors and windows , open rebated & prepared to receive glass, gauge etc. (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, Section-8, Clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
S&F in repairs of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in old window and door shutter complete all as specified and directed.
S&F of stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple in new window and door shutter complete all as specified and directed.
S&F of 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F of 4mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane including hacking out old broken glass (any thickness and size, quality or description from wooden frame etc) fixed with putty or beads complete all as specified and directed.
S&F in repairs of 20mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc complete all as specified and directed.
S&F of aluminium bracket (heavy duty), powder coated of best quality as approved suitable for fixing 20mm bore curtain rod fixed in wall complete all as specified and directed.
S&F in repairs of HDHMR board 18 mm thick both side laminated any colour, 18mm thick shutter, vertical support and horizontal shelfs including necessary fitting of screws in kitchen cupboard/bedroom cupboard complete all as specified and as directed.
M&L for 18/19 mm thick prelaminated particle board, exterior grade, prelaminated both side with decorative choice lamination, fixed with screws to aluminum frame work for cupboard shutter including taking down old unserviceable one complete all as specified and directed.
S&F in repairs of stainless steel telescoping channel for drawer including necessary fitting upto length upto 800mm complete all as specified and directed.
S&F in repairs of soft close stainless steel hinges complete all as specified and directed.
S&F in repairs of gunmetal handle complete all as specified and directed.
S&F in repairs of continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 40mm complete all as specified and directed.
S&F of mild steel hold fast made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
M&L for PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in brick or concrete wall complete all as specified and directed.
S&F of 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F of 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F of 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F of 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, sliding/fixed type without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges type B-21, 100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etc including locking arrangement, roller complete all as specified and directed.
S&F of anodised (powder coating of minimum thickness 50 micron)aluminium frame of doors, windows, ventilators with one or more rebates including joining cleat for fixing for complete all as specified and directed.
Dismantling structural steel work including fencing post, doors, windows, gates but excluding framed truss etc. complete all as specified and directed.
S&F of steel windows with side hung shutters (glazed ) including box type hinges with steel handle, steel peg stay, complete with glazing bars, dovetailed or welded to receive wire mesh/glass complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for vitrified light shade (shade as approved) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set over and including 15mm screed bed in cement mortar (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed.
Ditto-all as per Item No.38.00 here-in-before but in skirting/dado over and including a backing coat of 10mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:4) for laying floor finishes complete all as specified and directed.
M&L for 18-20mm thick granite (any type) work (table rubbed and polished) machine cut in steps, jambs, pillars, window cill, cooking platform etc bedded and jointed with grey cement slurry and pointed with white cement (1:2) using marble dust with admixture of pigment to match the granite stone including and polishing over and including 15mm thick cement mortar (1:4) as screed bed complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for glazed ceramic coloured wall tiles (vertical) 350mm x 250mm x 7mm / 450mm X 300mm X 7mm thick or equivalent set and jointed neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles as in skirting/dado/vertical wall over and including 10 mm thick cement plaster in cement mortar (1:3) complete all as specified and directed.
Demolition of cement concrete in ground floors & paving not exceeding 15cm thick (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specially provided for complete all as specified and directed.
Demolition of cement concrete (un-reinforced) as in roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection, paving, floor, hard standing, sub base floor etc including finishing the cement concrete surface even and fair without using extra cement complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
M&L for brick work with sub class 'B' bricks locally available best quality straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks locally available best quality , straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on other than fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with WPC @200ml/50 Kg of cement, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkaline resistant primer over 3mm thick white wall care putty after preparation of newly plastered surfaces of wall complete all as specified and directed.
M&L for applying two coats of 100% Premium acrylic emulsion paint(using AIR-LESS PAINT SPRAYER) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over wall surfaces by using AIR-LESS PAINT PRIMER SPRAYER using smart technique including preparation/levelling of new surface of wall using manual sand papers(where reqd) of approved grade complete all as specified and as directed.
M&L for complete removal of existing wall surfaces and applying two or more coats of 100% Premium acrylic emulsion paint using air less paint sprayer having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @0.90 litre/ 10 sqm using smart technique over old surfaces complete all as specified and directed.
M&L for applying two coats of oil bound distemper over a coat of alkaline resistant primer after preparation of newly plastered surfaces of ceiling complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint (1st grade quality) over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying one coat of oil emulsion distemper over old decorated plaster surfaces of ceiling after preparation of surfaces complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint (1st grade quality) after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
S&F in repairs of 15mm dia bib tap, two way, cast copper alloy fancy type with chromium plated complete all as specified and directed.
S&F in repairs of soap dish, chromium plated, fixed to plugs with chromium plated brass screws complete all as specified and directed.
S&F in repairs of 15mm dia bib tap, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F in repairs of 15mm dia bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (minimum weight 15 mm-90 gms) complete all specified and directed.
S&F in repairs of 15 mm bore angular stop valve, fancy type, chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and directed.
S&F in repairs of brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F in repairs of vitreous china wash basin, white, flat back, size 580 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F in repairs of 15mm dia pillar tap, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F in repairs of sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs of health faucet fixed to EWC with 1mtr long easy flexible tube of 8mm dia and wall hook complete all as specified and directed.
S&F in repairs of 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed.
S&F in repairs of 125mm size brass chromium plated shower roses with arms, swivel joints, including fixing to steel pipe or union complete all as specified and directed.
S&F in repairs of 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia suitable for low level cistern fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F in repairs of vitreous china wash down water closet pan (pedestal pattern) white with 'P' or 'S' trap type(excluding flushing cistern & flush pipe) including connection to trap with 110mm PVC (SWR) connection and lip ring & to flushing pipe, anti-syphonage pipe out in with and including white seat cover etc. including making good to floor complete all as specified and directed.
S&F in repairs of PVC water closet seat cover, white/black colour as required, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F in repairs of PTMT bathroom cabinet with mirror of size not less than 350mm X 450mm complete all as specified and directed.
S&F in repair of chromium plated towel ring of 200mm dia with round flange complete all as specified and directed.
S&F in repairs of 15 mm dia PVC connection pipe of length 600 mm with PTMT nuts complete all as specified and directed.
S&F of 40 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc.complete including taking down old unserviceable pipe all as specified and directed.
S&F in repair of toilet paper holder fixed to walls with chromium plated (CP) brass screws all as specified and directed by Engr-in-Charge.
S&F of 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 20mm dia ball valve high pressure of PTMT (minimum weight 210 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F of 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm dia ball valve high pressure of PTMT (minimum weight 455 gms) including dismantling / taking down old unserviceable PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F in repairs of Corner glass shelf (large) 300 X 300mm (12" x 12") complete all as specified and directed.
S&F in repairs of 20mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F of 15mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 20 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F of 20mm dia tubes (medium grade) galvanised iron, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing unserviceable steel tubing complete all as specified and directed.
S&F in repairs of 125/110mm dia PVC (SWR) gully trap , settings and jointing with solvent cement complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable pipe complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable pipe complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F of 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F in repair of wall mixer 3-in-1 system with provision for both hand shower and OH shower complete with 115mm long bend pipe, connecting legs & Wall Flange (without hand & over head shower) complete all as specified and directed.
S&F of stainless steel plate rack (0.63 mm thick s/s sheet) of size 775mmX900mmX250mm fixed in wall with stainless steel screw of suitable size complete all as specified and directed.
M&L for reinforced cement concrete (1:1.5:3) (Nominal mix) type A1 (using 20 mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies and in shelves complete all as specified and directed.
M&L for TMT bars 6 to 8 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F in repairs of glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs of 50mm to 60mm aluminium peg hook/ wardrobe hook (single) complete all as specified and directed.
Demolition of PCC and backing coat of any thickness and any type including taking out of existing un-serviceable tarfelt / bituminous membrane on roof and parapet of any roof height carefully by cutting chiseling or by any mechanical way, cleaning the surface by scraping, brooming, brushing etc and rubbish off the premises and applying neat cement slurry @3 Kg per Sqm complete all as specified and directed.
M&L for 25 mm (avg) thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding / levelling course mixed with WPC @200ml/50 Kg of cement finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item)
M&L for rendering 20 mm thick plastering in cement mortar (1:3) on concrete surfaces of walls and roof mixed with WPC @200ml/50 Kg of cement finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item)
M&L for cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for PCC (1:5:10) type E-2(using 40mm graded stone aggregate) as in filling sunken floor of bathroom/toilets etc complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:3) to sunken portion of slab with using liquid water proofing compound @200mm/50 Kg of cement finished even and smooth without using extra cement complete all as specified and directed. (Note :- WPC will be measured & paid seperately under relevant item)
PART-II Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper over applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing caping of suitable size and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of top cover , blanking plate as per numbers of switches, sockets, fan regulators, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper as applicable after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- (i) All necessary accessories such as modular box, top cover plate, blank plate, screws, washers etc are to be used of same make/brand only in relevant items. (ii) Cutting & chasing of wall for point wiring at any height shall be done and cost of the same deemed to be including with quoted rate.)
One light point controlled by one switch
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch.
One 5 pin 6 Amps socket point controlled by one 6 Amps switch on independent board.
One 5 pin 6 Amps socket point controlled by one 6 Amps switch on same board.
One bell/buzzer point controlled by one bell push.
One light point controlled by two 2 way switches.
Ditto - all as per Item No.116.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on independent board.
One 6 pin 16/6 Amps socket outlet point controlled by one 16 Amps switch on same board.
Ditto- all as per item No. 116.00 here-in-before but point wiring with 4.0 sqmm and earth conductor of size 4.0 sqmm complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular switch 10 Amps, single pole, 2 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular type bell push 10 Amps, single pole, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular type switch 16 Amps, single pole, 1way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F of modular socket shuttered type 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F of modular red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F of modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F of call bell, AC, 230 Volts single pole, multi music type ISI marked complete all as specified and directed.
S&F of angle lamp holder, insulated body with back plate for batten fittings with and including LED lamp 10 watts complete all as specified and directed.
S&F of ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F of decorative box type 20 -22watt LED fittings with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH & Tube cat No. PHOTONULTRAE2.01213T8SSTL20WLED865SPC/Philips Cat No. TMC501P1XT LED 22WP 3241 for batten and Essential LED TUBE 20W B2B865T8 for tube/SURYA Cat No. SUB118T8LED for batten and SLE TL DS 20 PC REFORM (NANO) for tube or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size other fixing accessories complete all as specified and directed. (Make: Philips Cat No. WT202W LED 6 SCW PSU S2PC/Havells Cat No. LUMILINE + BS10WLED 865 SPCSS/SURYA Cat No. SLEBT10IL or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F LED light fitting 1x9W/1x10W bulk head luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including fixing arrangements at any hight with nuts, screws and washers and connected to ceiling rose complete all as specified and directed. (Make: Philips Cat No. WT202WLED6SCWPSUS2PC/SURYA Cat No. SLE BH 10W/Bajaj Cat No. BIBWP10W LED or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F LED light fitting 1x6W wall mounted decorative surface mounted connecting with three core flexible copper conductor cable of suitable size including fixing arrangements at any hight with nuts, screws and washers and connected to ceiling rose complete all as specified and directed. (Make: Crompton Cat No. LCSR-06-CD/ SURYA Cat No. sle dls 6W XX Steller RD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 8 way 8+24 modules suitable for flush mounting with 100 Amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make:- Legrand cat No. 5076 82 8 way /L&T Cat No. DBTPN008GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 12 way for flush mounting with 200 Amps copper busbar, neutral bar, earth bar suitable for MCB incomer of rating upto 200Amps, MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plates with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat including taking down old unserviceable one complete all as specified and as directed. (Make:- Legrand cat No. 5076 22 12 way /L&T Cat No. DBSPN012GD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed.
S&F of MCB SPN 40 to 63 Amps, 10 KA, 'C' series, AC, 240Volts, 50Hz, ISI marked complete all as specified and directed.
S&F of MCB, four pole, 40 Amps to 63 Amps, 'C' Series, 415 Volts, 50Hz, ISI marked complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed.
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work including taking down old unserviceable submain wiring complete all as specified and directed . (Note for item No.139.00 to 140.00 : (i)Two runs of cable with one run earth wire and PVC conduit shall be measured as one length. (ii) Extra length of cable required for connection to DBs shall be deemed to be included in the unit rate and shall not be measured separately. (iii) Earth wire shall run inside the conduit. (iv) Suitable color code of wire must be ensured for phase/netural/earth. (iv) All surface cutting/making good for wiring/switch board/junction box/DB etc are included with unit quoted rate.)
S&F of flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts after and including taking down of unserviceable one complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F in repairs of MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz complete all as specified and directed. (Make - L&T Cat No. CM91712OOKOOG or equivalent of Legrand Cat No. 4200-55 or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
M&L for earthing with glavanised steel earth plate electrode of size 600mmX600mmX6mm thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to the galvanised earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel using GI or steel wire 4mm dia as earthing lead as shown in electrical plate No.3 of SSR Part-I connected to earthing test point all specified or indicated including testing on completion including necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC (1:3:6) type C-1 using 20mm graded stone aggregate pit, funnel, 20mm dia GI medium grade watering pipe , 15mm dia GI medium grade earth lead protection pipe and pre-cast earth pit cover 50mm thick made of RCC (1:1.5:3) type A-1 duly reinforced with 8mm dia TMT bar @150c/c both ways, one lifting handle made out of 10mm dia TMT bar 250 mm long embedded in cover slab and cover, wire, copper lugs etc mesh, charcoal and common salt in alternate layer of 15 cm thick including taking down old earthing complete all as specified and directed. (Notre: Galvanised iron wire of 4mm dia upto 7.5m long including testing is deemed to be included with quoted rate).
M&L for 40 mm bore GI pipe (medium grade) fixed with wall with maximum span of 4.0 meters suitable for hanging of ceiling fan with and including necessary cutting hole in brick/stone wall and making good the same with PCC (1:2:4) type B-1 as required including taking down old unserviceable pipe complete all as specified and directed.
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm thick -02 Nos flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer including taking down old unserviceable brackets complete all as specified and directed.
S&F for 70/72 watt LED secruity light fitting, with LED lamps in aluminium PDC housing, toughened glass cover with IP66 protection with minimum 4kv inbuilt surge protector and cable connection from looping box to light fitting and testing after and including taking down existing unserviceable light fittings complete all as specified and directed . (Make:- Bajaj Cat No. BRTFG 72W LED V3/ Crompton cat No.CRP-409-70-57-SL-GL-NSG /Havells cat No.ENDURACITYLINERNEOSL70WLED757PASYBOTG or equivalent model/Cat No of make as per Appx 'D' as mentioned in PS here-in-after)
S&F of ceiling fan with blades, down rods and all accessories, 230 volts, 1400 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) type and including hanging GI hook with necessary suitable MS clamp and connecting cable three core, 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing complete all as specified and directed.
S&F of heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for exhaust fan made of sturdy engineering plastic complete with louvers shutter, voltage 230 volts, 50 Hz, 1200 RPM, copper winding of sweep 250 mm including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects after complete including taking down old unserviceable fan and deposited to MES store yard complete all as specified and directed.
Taking down of electric meter of any make and capacity from any height and removing from frame and refixing the same including removing unserviceable, nuts and bolts and cleaning and reassembling complete including replacement of wornout spares and refixing the same to its original position and proper electric connection to be made and all as specified and directed.
Supply, fixing and commissioning water heater storage type, eletric operated, capacity 25 Litres, BEE 5 Star rated complete with all connected accessories suitable for AC supply, 240 volts, 50 Hz including connecting with water supply pipe line and all water and electrical connection complete with necessary PVC connection pipe all as specified and directed. (Make: Crompton Model No. Arno Neo 25-L5 Star, Bajaj Model No. Montage 25L 5 Star or equivalent model/make as Appx 'D' of PS)
BHASKAR SUPPLY AGENCY
N C DUTTA
FALCONS INDIA
M/S. ARUP KUMAR DEY
BEE ROMEN
NANDY ENTERPRISE
SHANKAR CONSTRUCTION CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .