Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 LAccepted-AOC HIJALPUKUR M M DUTTA ROAD HABRA 24 PARAGANS N | HABRA | 24 PARAGANS N | WEST BENGAL | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.2 L+₹60,173 (13.0%)Rejected-Finance MAHARAJAHAT RAIGANJ UTTAR DINAJPUR PIN 733 156 | RAIGANJ | UTTAR DINAJPUR | WEST BENGAL | 733156 | L2 | Rejected-Finance L2 | |
| 3 | L3₹5.4 L+₹77,557 (16.7%)Rejected-Finance PM 3 6 TEGHORIA MONDAL PARA 3RD LANE KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L3 | Rejected-Finance L3 |
Tender Value
Refer Docs
EMD Value
₹11,956
Closing Date
27 Jan 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Room No. 108, Purta Bhawan, Salt Lake
Room No. 108, Purta Bhawan, Salt Lake
Repair and renovation of damaged distribution wiring and replacement of damaged light fittings at CD cut-out at Vivekananda Yuba Bharati Krirangan, Salt Lake, and Kolkata---- as and when required
2025_WBPWD_799706_1
WBPWD/EE/BED/e-NIQ-72/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Vivekananda Yuba Bharati Krirangan
Please refer Tender documents.
5 documents required · 5 mandatory
₹11,956
7 Feb 2025
13 Jan 2025
24 Nov 2025
20 Jan 2025
27 Jan 2025
20 Jan 2025
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. Average Run 11 mtr.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment- 2+4 Way SPNDB (Make- Legrand / Schneider / ABB-Elegance Series/ Siemens) Incommer 230V 40A DP MCB Isolator - 1 No, Outgoing 1) 6A- 32A,10KA, SP MCB - 4 Nos
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required as to GS. a) 3 x 22/0.3 (1.5 sq. mm.) as ECC (interconnection wire)
b) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
Supply of Recess Mounted circular LED round slim down lighter made from the die cast aluminium body having system lumen output not less than 900 lumen, power input not more than 15 watt colour temparature 4000K / 6500K (as per site requirement), CRI > 80, IP rating 20 or better.
Supply of Recess Mounted circular LED Squire slim down lighter made from the die cast aluminium body having system lumen output not less than 900 lumen, power input not more than 15 watt colour temparature 6500K (as per site requirement), CRI > 80, IP rating 20 or better. (Make- Philips/Crompton/Wipro )
Supply of Recess Mounted circular 6 watt LED adjustable (upto 25º vertical system) down lighter made from the die cast aluminium body having system lumen output not less than 500 lumen, colour temparature 4000K (as per site requirement), CRI > 80, IP rating 20 or better, lumen efficiency not less than 100 lumen/watt. (Make- Philips/Crompton/Wipro )
Supply of Recess Mounted square 2 ft x 2 ft 36 watt LED fitting with energy efficient diffuser having system lumen output not less than 3600 lumen, colour temparature 4000K (as per site requirement), CRI > 80, IP rating 20 or better, lumen efficiency not less than 100 lumen/watt. ( Make- Philips RC380B LED42S- 6500 G6 L60W60 PSU OD S1/ Wipro CRCO1ORO3OHP57G3 ) as per direction of EIC.
Supply of High performance 90-100 watt street light delivering 120 lumen/watt with high power LED light source with IP66 protection, PDC housing and high impact resistance (IK07) glass cover luminaire as per direction of EIC. (Make- Philips/Crompton/Wipro)
Supply of 240V, 16 A 5 pin Piano key type Scoket (Colour - Brouwn/White) (Make - Anchore/Legrand/Havells)
Supply of 240V, 16 A Piano key type Switch (Colour - Brouwn/White) (Make - Anchore/Legrand/Havells)
Supply of 240V, 16 A Plug Top (Colour - Brouwn/White) (Make - Anchore/Legrand/Havells)
Supply of 240V, 6 A Plug Top (Colour - Brouwn/White) (Make - Anchore/Legrand/Havells)
Supply of 3 watt 2 inch round recess mounted LED spot light.(Make - Philips/wipro/syska/Wipro)
Supply of 20 watt 4 ft LED Bright linear light fittings. (Make - Philips/CG/Wipro/Syska)(Colour Temparature - 4000k)
Supply of 1.5 sq. mm. Cu. wire (180 mtr per coil) (Make - Havells/KEI/Polycab) Note : 1) Normal works should be started within 16 hrs & for emergency breakdown work within 8 hrs, with sufficient manpower after getting information. 2) Materials of minimum quantity . Like wire, LED fittings, switch, socket, plug top etc. should be store in the site by agency by own responsibility for emergency work. Each individual work must be completed with minimum executing time as per site requirement. 3) The Agency must submit the details of communicating person in this regard along with his contact details.
Note:- Rate should be quoted inclusive of all taxes and duties including GST.
ANITA CHATTERJEE (BID ID -6029378)
PHINIX (BID ID -6037190)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .