| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L1 | Accepted-AOC LOWEST TENDER | |
| 2 | L2₹30.0 L+₹51,233.65 (1.74%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹32.8 L+₹3.3 L (11.2%)Rejected-Finance FLAT NO 305 SUBBARAO RESIDENCY THENNETI NAGAR MURALI NAGAR VISAKHAPATNAM 07 | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹33.6 L+₹4.2 L (14.2%)Rejected-Finance DOOR NO 36 72 5 BOOSAVARI STREET REDDY KANCHARAPALEM VISAKHAPATNAM 530 008 | VISAKHAPATANAM | ANDHRA PRADESH | 530008 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹35.3 L+₹5.8 L (19.7%)Rejected-Finance 66 6 410 1 MULAGANDA HOUSING COLONY GAJUWAKA DEPOT VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
4 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Utility-II
Garrison Engineer Utility-II 104 Area Industrial Estate Post Visakhapatnam -530 007
REPAIR MAINTENANCE OF WATER SUPPLY INSTALLATIONS AND DISTRIBUTION PIPE LINES AT NAVAL BASE AREA UNDER AGE E M NO I OF GE UTILITY II VISAKHAPATNAM
2021_MES_414103_1
8748
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Garrison Engineer Utility-II Visakhapatnam
CLASS D
8 documents required · 8 mandatory
₹500
Garrison Engineer Utility-II
₹96,000
Yes
18 Mar 2021
4 Feb 2021
5 Mar 2021
4 Feb 2021
4 Mar 2021
20 Feb 2021
60 days
Amount
Supply & Laying XLPE insulated, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 25 Sqmm, 4 core in trenches/along pole including taking out old unserviceable cable of any size etc complete all as specified and directed. Note :-(i) Excavation and earth work, sand cushiong, brick cover shall be measured and paid separately under respective items of Sch'A' Part-I
Supply & Laying XLPE insulated, screened , PVC bedded and PVC tape sheathed galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 volts grade with stranded aluminium conductor of size 16 Sqmm, 4 core in trenches/along pole including taking out old unserviceable cable of any size etc complete all as specified and directed. Note :-(i) Excavation and earth work, sand cushiong, brick cover shall be measured and paid separately under respective items of Sch'A' Part-I
Material and labour in repairs for fabrication, supply and installation and in replacement of dust & vermin proof cubical compartmentalised, indoor installation type Lt Panel protection class - IP-55, made out of 1.6mm thick CRCA sheet with RAC7032 powder coating swith detachable cable gland plates after seven tank treatment of the sheet painting will be done with epoxy based power coating siemens grey comprising of the following :-
Incoming :-
100A, 25 KA, TPN MCCB with thermal magnetic based O/I, S/C releases with extended rotary handle - 1 No.
Digital Voltmeter and Ammeter - 1 each
100/5A CT Coil - 1.0 = 3 Nos (Make : Srestaa or equilent)
R, Y, B indication lamps - 3 Nos
6A SP MCB - 4 Nos
Outgoing :-
12.5 HP S/D Feeder x 2 Nos consisting of following
63A TP MCB - 1 No.
32A TP power contactors (for main & delta) with 230V AC Couil with 2NO + 2NC auxiliary contact blocks - 2 Nos
25A TP Power Contactor (for Star) with 230V AC Coil with 2NO +2NC auxialary contact blocks 1 No.
9-15A Thermal overload relay - 1 No.
Star-Delta timer 1 No. inst & 1NO delayed 3-60 sec, 230V-400V AC - 1 No.
On/Off illumination push button (green with NO contact and Red with NC contact) - 2 Nos
Trip Indication Lamp - 1 No.
Taking down carefully the existing unserviceable surface conduit type aluminum point wiring for light, fan socket 5 amps/15 amps complete removing the same including fittings/fixtures and making good the disturbed surfaces of walls, floors, ceiling etc complete all as specified and directed.
Point wiring complete with 1.5 sqmm PVC FRLS insulated unsheathed multistranded copper conductor drawn through and including non metalic PVC rigid gray/black colour conduit pipe 20 mm dia fixed on suface of wall/ceiling etc with necessary conduit accessories incl 1.6 mm thick pressed steel terminal boxes concealed/ in walls covered with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated or brass screws for housing switches,socket outlets, fan regulators etc including provision of 1.5 sqmm single core PVC insulated unsheathed copper cable with multistranded conductors as earth continuity wire connected to common earth dolly all as specified and as directed for :-
One light point controlled by one switch
One fan point controlled by one switch.
One 3 pin 5 Amps socket outlet point on independent board
One 3 pin 5 Amps socket point on the same board with other switches
All as per item No 5 here in before but wiring with 2.5 sqmm and earth wire 1.5 Sqmm unsheathed single core PVC insulated multistranded copper conductor for 3 pin 15 Amps socket outlet
M & L for switch piano type, 5 Amps single pole one way
M&L for switch socket combination 2 in 1, 3 pin 5 Amps flush type universal.
M&L for switch socket combination 3 pin 5 Amps and 15 Amps flush type.
M&L for ceiling rose surface bakelite 65x50 mm two to three terminals.
Supply and fix for electronic type speed variable/step type fan regulator 230 volt, AC complete.
Taking down submain wiring and M&L for sub-main wiring with two single core FRLS PVC insulated, unsheathed, multistranded copper conductor cable of size 4 sqmm 1100 volts grade and including non metallic rigid 20mm dia PVC conduit with all fitting and fixing accessories and including PVC insulated unsheathed, multistranded copper conductor cable of size 2.5 sqmm for earth continuity conductor and including taking down old unserviceable sub main wiring complete all as specified and directed. Note :-2 runs of cable, one run of earth wire (copper cable) & one run of PVC conduit shall be measured as one running metre.
S&F sheet metal enclosure single pole and neutral , 240 volts, 8 way double door with 200 Amps rated bus bar including taking down unserviceable DB/main switch
S&F sheet metal enclosure single pole and neutral , 240 volts, 4 way double door with 200 Amps rated bus bar including taking down unserviceable DB/main switch
S&F for MCB single pole, 240 volts 6 to 32 Amps
S&F for MCB single pole and neutral 6 to 32 Amps, 240 Volts
Supply and Fixing street light fitting of New generation energy saving & environmental friendly long life Versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source and electronic driver suitable for pole dia upto 40mm including GI pipe bracket made of 40mm dia pipe light grade of length not less than 1.2m bent to shape as required fixed with and including necessary MS clamps, bolts, nuts and washers duly painted with two coats of synthetic enamel paint over a coat of red oxide primer including taking down old fittings complete all as specified and directed by the Engineer-in-Charge. [Make: Surya Roshini of Cat No. SLE UL150W IP66 LXN or its equivalent in Philips / Bajaj / CG / Havells / Wipro / GE]
Supply & fix in repairs LED tube light along with fixture,18W Make : Havells Cat Part NoLHEWEBP51N1W020 or equivalent in Bajaj/Philips complete all as specified and directed by the Engineer-in-Charge.
S&F in repairs steel rolling shutters of thickness 1.00 mm of laths with ball bearing as specified incl top cover anchoring rod hasp and staple and one shop coat of primer erected in position as indicated complete push pull or manual type and safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by the Engineer-in-Charge
Preparation of new steel surfaces of any description, exc 10 cm width or girth, and applying two coats of synthetic enamel paint complete all as specified and directed by the Engineer-in-Charge
Taking down Chowkats or frames not exceeding 1.5 Sq. M each (Without taking off shutters from the frames) complete all as specified and directed by the Engineer-in-Charge.
Taking down shutters exceeding 1.0 Sq. M but not exceeding 2 Sq. M each complete all as specified and directed by the Engineer-in-Charge
S&F Flush shutters 40mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by the Engineer-in-Charge
S&F Factory made solid panel pvc door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by the Engineer-in-Charge
S & F 100 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed by the Engineer-in-Charge.
S & F 75 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed by the Engineer-in-Charge.
S & F 150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by the Engineer-in-Charge
S & F 100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed by the Engineer-in-Charge
S & F 150mm aluminum anodised bow handles complete all as specified and directed by the Engineer-in-Charge
S & F 100mm aluminum anodised bow handles complete all as specified and directed by the Engineer-in-Charge.
Supply and fix 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast Aluminium alloy complete all as specified and directed by the Engineer-in-Charge.
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and directed by the Engineer-in-Charge.
S/F in repairs of staineless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm fixed with wooden beadings all as specified by Engr-in-charge..
Taking up/down 15mm dia steel tubing and connections including removal complete all as specified and directed by the Engineer-in-Charge
Taking up/down 20mm dia steel tubing and connections including removal complete all as specified and directed by the Engineer-in-Charge
Taking up/down 25mm dia steel tubing and connections including removal complete all as specified and directed by the Engineer-in-Charge
S&F 15 mm dia for steel tubing, medium grade, galvanised with all fitting and fixed complete to wall, floors etc complete all as specified and directed by the Engineer-in-Charge
S&F 20 mm dia for steel tubing, medium grade, galvanised with all fitting and fixed complete to wall, floors etc complete all as specified and directed by the Engineer-in-Charge
S&F 25mm dia for steel tubing, medium grade, galvanised with all fitting and fixed complete to wall, floors etc complete all as specified and directed by the Engineer-in-Charge
S/F in repairs float valve of PVC 20mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass and fixed complete including nipple complete all as specified and directed by the Engineer-in-Charge
S & F in repairs PVC bib taps 15mm dia complete all as specified and directed by the Engineer-in-Charge
S/F in repairs vitreous china squatting pan of orrisa pattern of size 580x440mm colour to match the existing surface with P & S trap front of back with intergral foot rest incl connection to trap and to flushing pipe anti syphone pipe etc complete incl making good to floors complete all as specified and directed by the Engineer-in-Charge
S & F in repairs Vitreous China Ware Wash hand basin white, flat back, size 550 x 400 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed by the Engineer-in-Charge
S & F 32 mm dia., Waste fittings, brass chromium plated for glazed ware sinks, wash basins etc., with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed complete all as specified and directed by the Engineer-in-Charge.
S & F 32mm dia waste pipe fixed to vest coupling etc. of long complete all as specified and directed by the Engineer-in-Charge.
S & F in repairs PVC Connection both end screwed to iron pipes of 15mm dia 450mm long complete all as specified and directed by the Engineer-in-Charge.
S & F in repairs 15 mm bore Fancy type pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with angluar type and fly nuts, screwed for iron pipe and fixed complete all as specified and directed by the Engineer-in-Charge.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc complete all as specified and directed by the Engineer-in-Charge.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed by the Engineer-in-Charge
Taking down cement plaster on wall of any desdriptions incl racking out joints for key scrubbing with water etc complete all as specified and directed by the Engineer-in-Charge.
M&L for rendering 15 mm thick on brick masonry surfaces in cement mortar 1:6 and finished smooth and even without using extra cement.
M & L for preparing new plastered or un plastered surfaces of walls applying three coats of white wash complete all as specified and directed by the Engineer-in-Charge.
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness complete all as specified and directed by the Engineer-in-Charge..
M & L 75 mm thick PCC 1:2:4 type B2 (using 20 mm graded granite stone aggregate) in floorings including finishing the surface even and smooth using extra cement complete all as specified and directed by the Engineer-in-Charge..
M&L Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set jointed and pointed in neat cement slurry in floor over 20mm screed bed in cement mortar 1:6 complete all as specified and directed by the Engineer-in-Charge.
M&L for Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed by the Engineer-in-Charge.
M&L for sand filling under floor or in foundations including watering and consolidation complete all as specified and directed by the Engineer-in-Charge.
M&L 75 mm thick PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) in , plinth protection including finishing the surface even and smooth without using extra cement and laid in alternate bays complete all as specified and directed by the Engineer-in-Charge.
M&L for PCC (1:4:8) type C2 using 40 mm graded stone aggregate as in foundations, filling & mass concrete complete all as specified and directed by the Engineer-in-Charge.
Dismantling floor heart or wall tiling incl cement mortor bedding and rubbish off the premises complete all as specified and directed by the Engineer-in-Charge.
M/L for screed bed or bedding layer of mortor 20 mm thick in CM 1:6 for laying floors finishes etc complete all as specified and directed by the Engineer-in-Charge.
S&F Coloured non skid ceramic tiles of size 300x300x6 mm thick, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and directed by the Engineer-in-Charge..
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting complete all as specified and directed by the Engineer-in-Charge.
M/L for Coloured Glazed ceramic tiles 300 x 200 x 6 mm thick, set and jointed in neat cement slurry and pointed in white or Coloured cement to match complete all as specified and directed by the Engineer-in-Charge.
M & L for preparing old surfaces of walls by brooming down or by steel wire brushing and applying one coat of white wash complete all as specified and directed by the Engineer-in-Charge.
M&L for preparation of old plasterd surfaces and applying one coat of exterior weather coat paint complete all as specified and directed by the Engineer-in-Charge.
M&L for complete removal of existing treatment from wall and applying two coats of oil bound distemper over a coat of primer after finishing wall surface with one coat of JK/Birla wall care putty to get a smooth finish complete all as specified and directed by the Engineer-in-Charge.
Taking down existing roof treatment incl plastering below tar felt etc of any type any thickness and remove the same from work site exc 5KM out side the MD land complete all as specified and directed by the Engineer-in-Charge.
M & L for 10mm thick rendering in cement mortor 1:4 mixed with water proffing compound including brushing with neat cement slurry @ 3kg per Sq.M as in roofs (water proofing compound shall be menured separatly) complete all as specified and directed by the Engineer-in-Charge.
Supply only infegral water proofing compound.
Supply and lay HYPERPLAS-STANDARD 3kg/sq.M polymeric water proofing membrane incorporating a centre core of 90 micron thick HMHDPE film inclding coating the surface with a coat of water based bituminous primer @ 100gms/sq.M, followed by a coat of blown bitumen of grade 85/25 or 90/15 @ 1.2kg/Sq.M each at the top and bottom and applying of one coat of aluminium paint on the membrane complete including sealing all joints by themo fusion with minium 10cm overlap all as per manufacturers instructions complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m depth and getting out in soft/loose soil complete all as specified and directed by the Engineer-in-Charge.
PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) in bases / pedestals for pipe lines, mud stops or chamfered on edges and including demolition of existing PCC complete all as specified and directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick with excavated soil.
Removing surplus excavated soil n. exc. 50 m and depositing where directed at a level n-exc 1.5 m above the starting point.
Disconnect and remove the old unserviceable MCCB,200 Amps and supply and fix MCCB, 3 Pole 200 Amps, breaking capacity 36 KA with continously adjustable electronic release complete all as directed
Disconnect and remove the old unserviceable MCCB,125 Amps and supply and fix MCCB, 3 Pole 125 Amps, breaking capacity 36 KA with continously adjustable electronic release complete all as directed
Disconnect and remove the old unserviceable MCCB,100 Amps and supply and fix MCCB, 3 Pole 100 Amps, breaking capacity 36 KA with continously adjustable electronic release complete all as directed
Disconnect and remove the old unserviceable MCCB,63 Amps and supply and fix MCCB, 3 Pole 63 Amps, breaking capacity 36 KA with continously adjustable electronic release complete all as directed
Supply and replacement of Fully Automatic Star -Delta Starter with sigle phase protection for 3 phase motor, 415V, 50Hz for 30HP motor all as specified and directed by Engineer-in-Charge
Supply and replacement of Fully Automatic Star -Delta Starter with sigle phase protection for 3 phase motor, 415V,50Hz for120HP motor all as specified and directed by Engineer-in-Charge
Supply and replacement of 150mm dia butterfly valve PN 1.0 shall conform to BS:5155 including nut and botls connecting with all as specified and directed by Engineer-in-Charge
Disconnect and remove the old unserviceable MCCB and supply and fix MCCB, 4 Pole 400 Amps, breaking capacity 36 KA with continously adjustable electronic release complete all as specified and directed by Engineer-in-Charge
THE VENKATESWARA SUPPLIERS
SREE GAYATRI INFRA
CHAMUNDESWARI ENTERPRISES
GVR CONSTRUCTIONS
M/S EVEREST INFRA
SRIESWARI ENTERPRISES
M/S S K ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .