Providing EI works for making provisions of separate electricity service connection of MDs office building 1 no each on First floor Second floor and 1 no at newly constructed building adjacent to the DM office Agartala West Tripura 2nd Call
2026_CEPWD_70657_1
EE_IED_AGT_144_2025_26
Open Tender
Electrical Works
Percentage
30 days
DM Office Agartala
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹10,470
7 Mar 2026
20 Feb 2026
25 Feb 2026
20 Feb 2026
25 Feb 2026
20 Feb 2026
Wiring for circuit /Sub-main with following sizes PVC insulated copper conductor cable (FR) in PVC casing and capping etc. as required.
2 X 6 sq mm
4 X 10 sq mm
4 X 16 sq mm
4 x25 sq mm
Wiring for Circuit/Sub-main with the following sizes of PVC insulated Copper conductor cable (FR) in existing PVC casing capping/ conduit in recess/surface including connection etc. as required:-
1 X 6 sq mm
1 X 10 sq mm
4 X 50 sq mm
Supplying and fixing of the following sizes PVC conduit (medium gauge) on surface with all accessories etc. as required.
Supply and fixing of 25mm x 5mm GI strip on wall/ floor of the building for horizontal/ vertical run including necessary spacers and porcelain insulators at regular intervals.
Supplying and installation of powder coated steel sheet enclosure (MCB DB) suitable for 240/415 volts MCB/Isolator/RCCB (SP/SPN/DP/TP/TPN/FP) complete with necessary bus bar, neutral link, din rail, earth bar etc i/c connection as required.
6 way vertical TPN MCB DB suitable for FP MCCB incomer upto 125 amps (Double door):-
Supplying and installation of powder coated steel sheet enclosure for 415 volts MCCB (TP/FP) complete with necessary connection etc as required:-
Enclosure suitable for MCCB above 100 amps upto 250 amps:-
Supplying & installation of 10 KA breaking capacity, B/C curve MCB of following ratings in the existing MCB DB including connection as required:-
40/50/63 amps FP MCB:-
Supplying & installation of TP/FP MCCB of following ratings in the existing MCCB enclosure/ panel board including connection etc as required (Ics=100% of Icu with adjustable settings):-
16 to 100 amps FP MCCB, Breaking capacity 16/18KA (Thermal Magnetic):-
160 amps FP MCCB, Breaking capacity 25KA (Thermal Magnetic) :-
Supplying and installation of fuse unit kitkat/HRC/HBC of the following ratings in existing main switch/panel board including necessary connection etc as required:-
200/250 amps kitkat porcelain fuse unit with base(rewireable):-
Supplying and laying of the following sizes XLPE insulated PVC sheathed aluminium conductor armoured cable with necessary connection etc as required
4 core 70 Sq mm
4 core 35 Sq mm
Supplying and fixing of aluminium terminal ends (LUGS) - long barrel of following sizes : -
Supplying and fixing of Copper terminal ends (LUGS) - long barrel of following sizes: -
Supplying and installation of Bus bar chamber of the following ratings and sizes made of steel sheet enclosure with all accessories including necessary connection etc. as required:-
200 amps 415 volts four strip Copper busbar chamber 4 ways of size (455mmx330mmx120mm):-
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_71904.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.80 MB
DNIT.pdf
Tender Documents • 2.89 MB
BOQ_71904.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .