Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1.2 CrAccepted-AOC BAID COMPLEX R K CHOUDHURY ROAD KUMAR PARA GUWAHATI 781001 ASSAM | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | ₹1.2 Cr | 1 | Accepted-AOC l1 and reasonable |
| 2 | 2₹1.5 CrRejected-Finance | ₹1.5 Cr | 2 | Rejected-Finance NOT L1 |
| 3 | Rejected-Technical B 86 GREEN PARK CHIPYINA NEAR JAAT CHOWK GAUTAM BUDH NAGAR 201009 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201009 | - | - | Rejected-Technical Due to not submitted requisite documents as per PQC criteria work experience and Turnover |
| Sl No | Description | Qty | Unit | AMIT ASSOCIATES L2 | R K ENGINEERING ASSEMBLE L1 |
|---|---|---|---|---|---|
| 0.00NOTE:- (i) Schedule 'A' Part I to VII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. (ii) Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates. | |||||
| 1.00 | Total amount of Sch 'A' Part I (BLDG INCL INTERNAL ELECTRIC AND WATER SUPPLY)
Note : Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 6,45,000 ₹6.5 L | 6,50,000 ₹6.5 L |
| 2.00 | Total amount of Sch 'A' Part-II (SITE CLEARANCE AND EARTH WORK).
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 2,20,000 ₹2.2 L | 1,50,000 ₹1.5 L |
| 3.00 | Total amount of Sch 'A' Part-III (EXTERNAL ELECTRIFICATIION).
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 5,00,000 ₹5 L | 3,90,000 ₹3.9 L |
| 4.00 | Total amount of Sch 'A' Part-IV (EXTERNAL WATER SUPPLY).
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 20,000 ₹20,000 | 15,000 ₹15,000 |
| 5.00 | Total amount of Sch 'A' Part-V (STAND BY POWER SUPPLY).
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 90,000 ₹90,000 | 70,000 ₹70,000 |
| 6.00 | Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL (B/R)).
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 2,50,000 ₹2.5 L | 2,20,000 ₹2.2 L |
| 7.00 | Total amount of Sch 'A' Part-VII (SEWAGE AND WASTE WATER DISPOSAL (E/M))
Note: Details of prepriced schedule are given in tender documents. | 1 | Lump sum | 2,00,000 ₹2 L | 1,50,000 ₹1.5 L |
| 8.00Sch 'A' Part-VIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only. | |||||
| 8.01 | Supply and laying for sub class B brick brick of size 225mm x 115mm x 65mm for protaction of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. | 4,187 | Nos | 17 ₹71,179 | 12 ₹50,244 |
Tender Value
₹1.3 Cr
EMD Value
₹2.0 L
Closing Date
30 Jul 2025, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati Assam Pin 781015
PROVN OF SEWAGE TREATMENT PLANT (STP) AND OUTSOURCING OF SREVICES FOR MANNING AND OPERATION OF SEWAGE TREATMENTS PLANT AT AF STN KUMBHIRGRAM
2025_MES_715348_1
CWE (AF)/KUM/TOKEN-18 OF 2025-26
Open Tender
Civil Works
1035 days
Kumbhirgram
As per tender documents
8 documents required · 8 mandatory
₹1,000
AGE (I) (AF) Kumbhirgram
₹2.0 L
Yes
24 Dec 2025
18 Jun 2025
1 Aug 2025
18 Jun 2025
30 Jul 2025
16 Jul 2025
Amount
NOTE:- (i) Schedule 'A' Part I to VII are Prepriced by MES. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. (ii) Applicable for all parts/items/):- The bidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and General conditions of contracts before entry/quoting the rates.
Total amount of Sch 'A' Part I (BLDG INCL INTERNAL ELECTRIC AND WATER SUPPLY) Note : Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-II (SITE CLEARANCE AND EARTH WORK). Note: Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-III (EXTERNAL ELECTRIFICATIION). Note: Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-IV (EXTERNAL WATER SUPPLY). Note: Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-V (STAND BY POWER SUPPLY). Note: Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-VI (SEWAGE DISPOSAL (B/R)). Note: Details of prepriced schedule are given in tender documents.
Total amount of Sch 'A' Part-VII (SEWAGE AND WASTE WATER DISPOSAL (E/M)) Note: Details of prepriced schedule are given in tender documents.
Sch 'A' Part-VIII (MISCELLANEOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col 5 signifies this fact only.
Supply and laying for sub class B brick brick of size 225mm x 115mm x 65mm for protaction of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
M & L for horizontal boring across the existing road without disturbing the road surface for inserting 50 mm bore GI pipe all complete all as specified and as directed. (Note :- GI pipe will be measured and paid respective item of Sch BoQ).
Supply, installing, testing and commissioning outdoor type LT feeder piller box of 1.0x0.8x0.5 Mtr size, pedestal mounted, CPRI approved factory made totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 500 volts, 50 Hz, 3 phase 4 wire system and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in. BUSBAR :- 100 Amps rated copper bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance INCOMING:- (a) MCB TPN of capacity 40 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 10 KA -01 No OUTGOING:- (a) MCB TPN of capacity 32 Amp breaking capacity 10 KA with thermal release, 415 volts 50 C/S, AC-1 Nos (b) MCB SPN of capacity 6-32 Amp breaking capacity 10 KA with thermal release, 415 volts 50 C/S, AC-2 Nos
S & F cable junction boxes weather proof for outdoor installation for loop connection of street light cable of size 205x255x112 mm with 5 pole terminals fixed on pole steel/PCC with suitable two flat iron clamp 25x4mm with nuts and bolts (duly painted with two coats of aluminium paint over a coat of red oxide primer) including provision for cable entry and exit and making holes on steel pole where required or directed complete all as specified and as directed. Make : Hensel or equivalent
M & L for street light bracket made out of GI pipe light grade 40mm dia 1.2 metre length bent to shape and reduced to required size at top upto 1.5 metre length by cutting, welding and well finishing including MS clamp of flat iron of size 40x6 suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats of aluminium paints over a coat of red oxide primer complete all as specified and as directed.
S & F in replacement PVC insulated and sheathed (ISI marked) stranded copper conductor 1.5 Sqmm size multi stranded for street light connection from fitting connector to the terminal box including all fixing arrangement, complete all as specified and directed
Supplying, installing, commissioning and testing complete of OEM (Original Eqpt Manufacturer) manufactured and tested static Silent Diesel Engine Driven Generating Set including inbuilt AMF panel capable of delivering 15 KVA, 415 volts (AC 3 Phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled through flexible coupling to a matching alternator and mounted on Dunlop metallastik foundation pads on a common base frame and threafter intalled in the CPCB approved acoustic enclosure (the complete set conforming to and test certified as per CPCB norms and as specified) all as specified complete with control panel standardised by manufacturer, flexible exhaust pipe complete including PCC foundation of suitable size as per manufacturer reccomendation for MCO DET Make:- KOEL/ASHOK LEYLAND/SUDHIR/ CUMMINS / Greavs and shall comprise of the followings :- (a) ENGINE (PRIME MOVER). Diesel Engine 1500 RPM of suitbale HP as recommended by manufacturer but not less than 20.5 BHP (at NTP) air cooled, Turbocharged aircooled, 1x 80 AH 12 Volts electric battery start, complete with fly wheel and all standard fittings/fixtures as per manufacturing practice including suitable engine control panel with tachometer, lub oil temp & pressure gauge, water temp guage and frequency meter (digital type) including safety shutdown contents) and also including self starter, dynamo, fuel tank etc and conforming to I.S. 10002, ISO 3046, BS-5514. The engine shall give electrical out put of 15 KVA at 0.8 PF.
(b) ALTERNATOR. AC alternator, self excited, self regulated, self ventilated, brushless design, conforming to BS 2613/IS 4722, 3 Phase, 415 volts, 50 Hz, 4 wire system output 15 KVA PF 0.8 1500 RPM insulation class `H' enclosure IP 23/TEFC complete with AVR with + 1% voltage regulation directly coupled to and match the above engine and capable for over load of 10% for one hr in 12 hr operation. (c) Dunlop Metallastick anti-vibration pads for mounting engine - alternator assembly on the base frame/plate. (d) BASE FRAME. Made out of structural steel as per Manufacturer's recommended design/specefications. (e) ACCOUSTIC ENCLOSURE. Provn of an integral type approved/certified acoustic enclosure as per CPCB norms for the DG sets restricted the noise level to 75 db at one meter along and temp rise within canopy shall not exceed 5° to 7° Celsius. It shall be made of 16 SWG CRCA MS sheet with powder coated finish on outside and provided with non igniting fire retardant foam as acoustic material. There shall be four hinged doors out of which one shall be with a glass window. The base frame shall be ISM section. It shall also include the followings:- (i) Silence absorption type, non-resistance, residential and exhaust pipe covered with asbestos rope lagging extending to about 2 mtrs outside the accoustic enclosures. (ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and flourescent lamp fittings.
RCC NP3 150 mm diameter Pipes laid on150 mm thick bed with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/Precast RCC with SFRC ventilating cover and frame. Includes all items and activities to execute and make sewer line functional 150mm th PCC Cradle1:4:8 for depth 0.70 - 1.65 mtr complete all as specified and as directed.
Supply, installation, testing and commissioning of Non clog vertical submersible pumps with chrome steel impeller and cutter, non-clog to pass 50 mm size particles including Supply, installation with guide rail and lifting chain, cables, Earthing, testing complete with 2 years maintenance, Capacity 01 HP (Flow and head= lpm x m) ie 145 LPM x 12 Mtrs hight complete as per specified. Make- Kirloskar or equivalent
Supply and Fix Submersible Pump Starter, 415V, 50Hz suitable for 01 HP complete all as per specified. Make - L&T or equivalent
Supply, installation, test and commissioning of PLC based indoor panel floor/wall mounted type,3 phase,415 volts,50 Hz for monitering,control of 04 Nos pumps,flow switch 01 No,ultrasonic level sensor.The panel shall be suitable size fabricated from 1.6 mm thick CRCA sheet and powder coated complete all as specified and directed.
Supply, installation, testing and commissioning of Monoblock pump set suitable for 415 V, 3 phase system having capacity 5 HP, 2900 RPM, Size-65x50mm, 8.5-5.8 LPS at 20-36 mtr head complete all as per specifed and directed complete. Make - Kirloskar or equivalent
M&L for fully automatic star delta starter complete of capacity of 05 HP Model MN 16 DOL, including electrical connections etc with PCC required for grouting in floor/ wall completed all as specified and directed. Make- L&T or equivalent
Supply, install testing and commissioning of " Sintex" package type STP (Make : Sintex/ Thermax/ Ion Exchange) ( PSTP-NBF Model) of capacity 50KLD/Day with tertiary treatment shall consists of the following components :- (i) Solid separation Zone (ii) Aeriation Zone (iii) FLoating Media (iv) Air blowers (Twin lobe type) (v) Final sedimentation Zone (vi) SLudge recycling pump (vii) COntrol Panel (viii) Inbuilt manholes with cover (ix) Material for anchoring the tank including FRP Straps & RCC Deadman. (a) Sintex type package domestic waste water treatment Plant-NBF-50 shall have the following with dimensions. (i) Sintex FRP based septic tank alongwith fixed film aeration tank of size 12.794M(Length)X2.43M(Diameter)- 01 No. (ii) Sintex type FRP base intermediate and Treated storage water tank with partition of capacity 25 KL (As recommended by manufacturer) of size 6.732MX2.43M(diameter)-01 No. (iii) Sludge reciprocating submersible pump of capacity 9cuM/Hr with motor capacity of 1HP-02 Nos( One working and one standby). (iv) Twin lobe air blowers with working pressure 03.Kg/cm2, Motor capacity 3HP and blower pipe of dia 3 inch- )2 Nos (One working and one stand by).
(v) Return sludge pipe of 2 inch dia, inlet and outlet pipe of dia 6 Inch and Interconnection pipe of Dia 6 inches (vi) Control panel of size 900mmX400mmX1000mm (Shall be as per manufacturer's recommendations)-01 No. (vii) FRP Strap of length 2.7 M -01 Lot( As per recommendations of manufacturer). (ix) Cast Iron turn buckle -01 Lot( As per recommendations of manufacturer). (x) MS wire rope of required length(Length as recommended by manufacturer)-01 Lot. (xi) Concrete deadman as per length of the tank-01 Lot. (xii) PVC air vent Nozzle of size 2 inch -( As per recommendations of manufacturer)-01 Lot. (xiii) Eye bolt -( As per recommendations of manufacturer)-01 Lot. (xiv) Manhole cover of size 550mm ( As per drawing provided by manufacturer). Tertiary treatment at outlet of sintex package type STP-50KLD Supply and fix tertiary treatment at outlet of sinte package type stp to achieve the out let parameters (BOD<10mg/lit and TSS <10mg/Lit) and tertiary treatment system shall cmprise of the following. (a). Activated Carbon filter-01 No (i) Vessel shall be FRP type (ii) Valve shall be Multi port valve (iii) UPVC/PVC pipe of dia -50mm( Required asper manufacturer's instruction)
(iv) Filter media suitable for activated carbon 1200I/V (v) Flow rate shall be 4 M3/Hr (b). Flow rate shall be 4 M3/Hr (i) Multigrade filter FRP type fileter (ii) UPVC/PVC pipe of dia-50mm (Required as per manufacturer's (iii) Multiport Valve (iv) Filter media- Gravels/Pebbles/Core Silex/Fine Silex/Sand (v) Flow rate 4 m3/Hr (c) Chlorine Dosing system (i) Hydrochlorite dosing system shall be of capacity 0-4 LPH -01 No (d) Feed water pump (One Working + One standby)-04 Nos (i) Size of Inlet-50mm and size of outlet-40mm (ii) Capacity of pump -02 HP
Sewage parameters shall be guarnteed at outlet of Sintex type Package STP. (i) PH 6.5-8.8 6.5-8.5 (ii) BOD 250-300mg/l <30 Mg/l (iii) COD 400-600 mg/l <150mg/l (iv) TSS 200Mg/l <50mg/l (v) FOG 40-50 ppm <5 mg/l The sewage parameters guarnteed at outlet of Sinte package type STP after tertiary treatment. (i) PH 6.5-8.8 6.5-8.5 (ii) BOD 250-300mg/l <10 Mg/l (iii) COD 400-600 mg/l <50mg/l (iv) TSS 200Mg/l <10mg/l (v) FOG 40-50 ppm <5 mg/l
Manning & Opearation during Defect Liability Period :-
Manning & Opearation for 1st 11 months during DLP
Outsourcing for operation of Sewage Treatment Plant (STP) package type capacity 50 KLD, including maintenance and operation of 15 KVA DG Set-01, Monoblock pump house capacity 5 HP-02 Nos, Non clog vertical submersible pump set capacity 01 HP-02 Nos, starter, panels, Security lights, Two Shift 08 hours each as directed by Engr-in-Charge (including sundays and holidays) by employing 01 Nos FGM (Skilled) & 01 Nos helper (Unskilled) in each shift for operation and maintemance of installation and including the following (i) Pumping/distribution/desposal of clear water with 02 nos pump sets 5HP, 02 Nos Pump sets 01 HP from sump of water including periodical maintenance of pumping sets as specified and directed and operation of valves in various distribution in the complex. (ii) Operation and periodical maintenance STP including cleaning of valves, gland packing of valves, leakage of valves, cleaning of tank as directed by Engineer-in-Charge. (iii) Operation and maintenance of DG set 15 KVA capacity of failure of main supply including day to day maintenance of DG set such as periodical checkup, replacement of engine oil filetrs, fan belt, hose pipe, oil leakage filter of POL as required basis all as specified and directed.
(iv) Operation and maintenance of all starter panel boards, Capacitor bank,LT panel, cable connection, day to day checking of all electrical connection, replacement of cable lugs, contact point etc.. (v) Distribution/ supply of clear/ raw water at different area or through filling point ( Zone A,B & C) and maintaining daily log sheet, water disstribution register, chlorine register and maintenance of all control valves in the respective areas. (vi) Preparation and maintenance of log sheet of DG sets, Pumping sets and attendance register and other associated documents as directed.
Water samples collecting at Raw water, treated water testing at authorised testing lab and producing the testing result in all respects as directed by engr-in-charge Note: The test to be carried out each quarter ending.
Manning & Opearation for 2nd 11 months during DLP
Outsourcing for operation of Sewage Treatment Plant (STP) package type capacity 50 KLD, including maintenance and operation of 15 KVA DG Set-01, Monoblock pump house capacity 5 HP-02 Nos, Non clog vertical submersible pump set capacity 01 HP-02 Nos, starter, panels, Security lights, Two Shift 08 hours each as directed by Engr-in-Charge (including sundays and holidays) by employing 01 Nos FGM (Skilled) & 01 Nos helper (Unskilled) in each shift for operation and maintemance of installation and including the following (i) Pumping/distribution/desposal of clear water with 02 nos pump sets 5HP, 02 Nos Pump sets 01 HP from sump of water including periodical maintenance of pumping sets as specified and directed and operation of valves in various distribution in the complex. (ii) Operation and periodical maintenance STP including cleaning of valves, gland packing of valves, leakage of valves, cleaning of tank as directed by Engineer-in-Charge. (iii) Operation and maintenance of DG set 15 KVA capacity of failure of main supply including day to day maintenance of DG set such as periodical checkup, replacement of engine oil filetrs, fan belt, hose pipe, oil leakage filter of POL as required basis all as specified and directed.
(iv) Operation and maintenance of all starter panel boards, Capacitor bank,LT panel, cable connection, day to day checking of all electrical connection, replacement of cable lugs, contact point etc.. (v) Distribution/ supply of clear/ raw water at different area or through filling point ( Zone A,B & C) and maintaining daily log sheet, water disstribution register, chlorine register and maintenance of all control valves in the respective areas. (vi) Preparation and maintenance of log sheet of DG sets, Pumping sets and attendance register and other associated documents as directed.
Water samples collecting at Raw water, treated water testing at authorised testing lab and producing the testing result in all respects as directed by engr-in-charge Note: The test to be carried out each quarter ending.
AMIT ASSOCIATES (BID ID -3374962)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid