| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.9 LAccepted-AOC | 1 | Accepted-AOC AWARDED BEING THE LOWEST TENDERER | |
| 2 | 2₹54.7 L+₹4.8 L (9.57%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹60.2 L+₹10.3 L (20.6%)Rejected-Finance | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹61.1 L+₹11.2 L (22.3%)Rejected-Finance D NO 9 947 66 DOCTORS COLONY SHIVAJI PLEM VISAKHAPATNAM 530017 | VISAKHAPATANAM | ANDHRA PRADESH | 530017 | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹65.8 L+₹15.9 L (31.8%)Rejected-Finance | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹45.7 L
EMD Value
₹91,400
Closing Date
17 Sept 2022, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GARRISON ENGINEER (NAVAL BASE), NAUSENABAUGH, GANDHIGRAM POST 530005
PROVN OF DEF CEILING FANS AT SAILORS MD ACCN AS PER MAP-II SPECIFICATIONS AT NSB AND PROVN OF ADDNL ELECTRICAL POINTS, WIRING AND AIR CONDITIONER AT DESIGNATED EXAM CENTRE (DEC) AT BLDG NP P-40 AT CIRCARS UNDER GE (NB) VISAKHAPATNAM
2021_MES_492118_7
C/8977/E8 / Token 84 of 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
VISAKHAPATNAM
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER NAVAL BASE
₹91,400
Yes
22 Sept 2022
26 Aug 2022
19 Sept 2022
26 Aug 2022
17 Sept 2022
3 Sept 2022
Amount
S & F energy efficient, low noise, ceiling fan, 1200 sweep, BEE 5 Star Rated with BLDC motor, copper wound conforming to IS-373, ISI marked, suitable for operation on single phase, 240 Volts AC, 50 Hz of approved colour including fan regulator, electronic type, down rod, canopies, 3 Nos blades, shackles, safety rope, hanging clamp, bushes and having power factor >0.94, service value >6.5, power consumption less than 35 Watts, air delivery >215cmm, THD less than 5% with speed control by electronic regulator including connecting up with 1.5 Sqmm, PVC insulated, multistranded copper conductor cables from ceiling rose to fan complete all as specified and directed. (Note: Ceiling fan should have minimum 3 years onsite replacement manufacturer's warranty)
S & F mild steel alloy D-Hook with 2 Nos M10x75mm expansion fastners hanger (heavy duty) fixed to ceiling for proper hanging of ceiling fan and making good disturbed surfaces to match with the existing one complete all as specified and directed.
M & L for Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore (Minimum) medium grade (ISI marked) surface fitted type including 3 module surface PVC box with cover plate for fixing modular type switches including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board for one light/exhaust fan/fan point/call bell controlled by one way switch complete all as specified and as directed. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface.)
All as per item No. 03 above but for One 3/5 pin socket outlet 6 amps on independent board complete ditto
All as per item No. 03 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 2.5 sqmm multistranded FRLS (ISI marked) and 2.5 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
All as per item No. 03 here in before but for one 15 Amps power point on the independent board with two runs of PVC insulated and unsheathed copper conductor cable of size 4 sqmm multistranded FRLS (ISI marked) and 4 sqmm PVC insulated unsheathed solid copper conductor cable FRLS (ISI marked) as earth lead complete ditto
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular socket outlet 6A, 2/3 pin combined, 2 module,AC 230V, 50HZ,conforming to IS 1293 :2005 (incl all revisons and amendments). complete all as specified and as directed.
S & F Modular Switch socket outlet multipurpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch, AC 230V, 50HZ, complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of Single core 2.5 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 2.5 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 2.5 sqmm and one runs of 2.5 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 4 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 4 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 2 runs of Single core 6 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 6 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Two runs of 6 sqmm and one runs of 6 sqmm cable as earth wire and one run of conduit shall be measured as one length)
M & L for Sub main wiring with 4 runs of Single core 10 sqmm [ for Phase & Neutral ] PVC insulated multi stranded FRLS (ISI marked) copper cable drawn through and including surface / ceiling / concealed PVC conduit of suitable size with all conduit accesories and fittings along with 1 run of single core 10 sqmm PVC insulated multi stranded FRLS (ISI marked) copper cable as earth continuity conductor complete all as specified and as directed. (Note :- Four runs of 10 sqmm and one runs of 10 sqmm cable as earth wire and one run of conduit shall be measured as one length)
S & F Vertical TPN DB double door for provision for four pole MCCB upto 160 A incommer 4 way 12 outgoing with IP 43 protectioncomplete all as specified and as directed. (Make : Legrand cat part No. 5077 45 or equivelant of make as per List of manufacturer's)
S & F Distribution Board, SPN 12 Way, 240V, Double door with IP 54 protection complete all as specified and as directed. (Make: Legrand cat part No. 5076 42 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SPN 40-63 Amps, 240 Volts, 10KA, C curve complete all as specified and as directed (Make: Legrand cat part No. 4086 18 to 20 or equivalent make as per List of Manufacturer's)
Supply, fixing, commissioning and testing MCB SP 6 to 32 Amps, 240 Volts, 10KA, C Curve, complete all as specified and as directed (Make: Legrand cat part No. 4085 87 to 95 or equivalent make as per List of Manufacturer's)
S & F MCCB 415 Volt 16 KA, 3 Pole, 100 Amps Capacity complete all as specified and as directed . (Make: Legrand Cat Part No. 4200 05 or equivelant of make as per List of Manufacturer's)
M & L Earthing complete with GI earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected with galvanised earth strip of size 32x6mm by means of bolts, nuts, check nuts and washers protected by 40mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, with 40 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 10 cm C/C both ways and suitable handle of 12 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel, wire mesh, aluminium lugs, complete in all respect and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
S & F Concealed sheet metal enclosure with socket plug top and MCBs having single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20Amp 240V, B-curve complete all as specified and as directed.
Supply, install, testing & Commissioning, Hi wall split air conditioner, Inverter type with indoor and outdoor units complete with cordless remote control unit and with virus deactivation technology and operate in winters as Air purifier, bushless DC motor with minimum 5 Star Rating and ISEER 4.65 of capacity 2 TR complete with all connecting pipes and fixing accessories such as bracket etc complete all as specified and directed. (Make: Blue Star Cat No. IC524DBTULV or equivalent as per List of manufacturer)
S & F voltage stabilizer for automatic operation,, single phase naturally air cooled indoor type and designed for input variation between 170 V to 250 V with output of 230V with accuracy of +/- 2.5% variation of capacity 5.0 KVA complete all as specified and directed.
S & F ceiling rose, 65 X 50mm two to three terminals, PVC/polycarbonate, insolated body complete all as specified and directed.
VIJAYA DURGA CONSTRUCTIONS
SHIRIDI SAI BUILDERS
SRIVALLI ENGINEERS
NIKESH ENTERPRISES
DELTA CONSTRUCTIONS
ANAND ENTERPRISES AND ENGINEERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .