Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC ERA 114 TC 36 819 PERUMTHANNI ERAVIPEROOR VALLAKADAVU POST THIRUVANANTHAPURAM 695008 | THIRUVANANTHAPURAM | KERALA | 695008 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.8 L+₹1.1 L (4.64%)Rejected-AOC VENUGEETHAM MRA T40 THACHANKARA LANE MARUTHANKUZHY TRIVANDRUM 695030 | THIRUVANANTHAPURAM | KERALA | 695030 | L2 | Rejected-AOC L2 | |
| 3 | L3₹27.4 L+₹2.8 L (11.3%)Rejected-AOC VP 10 323 CHITHRALAYAM NALANKALLU VILAVOORKAL MALAYINKEEZHU THIRUVANANTHAPURAM 695571 | THIRUVANANTHAPURAM | KERALA | 695571 | L3 | Rejected-AOC L3 |
Tender Value
₹27.7 L
EMD Value
₹50,000
Closing Date
30 Sept 2023, 3:00 pmClosed
Associate Vice President (HCD)
HLL Lifecare Limited, HLL Bhavan, No 26/4, Tambaram - Velachery Main Road, Pallikaranai, Chennai - 600 100, Tamilnadu, India
Civil and Electrical Works for Renovation of Ophthalmic OT Block in General Hospital Neyyattinkara, Thiruvananthapuram District
2023_HCDPS_605716_1
HLL/CHO/HCD/PS/GH-NTA/2023-24
Open Tender
Civil Works - Buildings
Item Rate
90 days
General Hospital Neyyattinkara
Please refer Tender documents.
12 documents required · 12 mandatory
₹2,950
Yes
₹50,000
Yes
18 Mar 2025
22 Sept 2023
3 Oct 2023
22 Sept 2023
30 Sept 2023
22 Sept 2023
Amount
Civil Work
DISMANTLING AND DEMOLISHING
Dismantling PUF panel/false ceiling including disposal of unserviceable surplus material and stacking of serviceable material with in 50 metres lead as directed by Engineer - in-Charge
Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge
PLASTERING
6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
WATERPROOFING
Providing and applying fibre reinforced elastomeric liquid water proofing membranewith resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top ofconcrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming ofelastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and twocoats of undiluted elastomeric waterproofing liquid (dry film thickness of completeapplication/system not less than 500 microns). The operation shall be carried outafter scrapping and properly cleaning the surface to remove loose particles withwire brushes, complete in all respect as per the direction of Engineer-in-Charge
DOORS and WINDOWS
Supply, Installation, Testing & Commissioning (SITC) of modular sandwiched doors of width1.5m width and 2.1m to 2.3m height both side GI powder coated sheet of 0.4mm thickness duly flushed with the walls, with 45 mm thick PUF, sandwiched between GI sheets, with seal door, including flushed hinges, view panels (as per the site requirement), SS 304 handle/ push plates and hydraulic door closers. Including Stainless steel hinges, Stainless Steel 'D' type handles on pull side, Stainless steel push plates on push side, Dorma make standard arm door closure (TS-68), View panel along with self-adhesive tape and silicon sealant, both side key operated locking arrangement, Door seal at the bottom & Sides, Stainless Steel kick plates, Filler material: Puff Insulation, Rock wool. Door complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, Colour, drawings and instructions of the Engineer-In charge.
WALL PANELLING
Supply Installation Testing & Commissioning (SITC) partitions with powder coated Galvanized Iron of 0.4 mm thick sheet on both sides, 50 mm thick class 'O' PUF of min.38kg/m3 density sandwiched in between. The surface shall be coated with 80-micron thick powder coating by hot dip galvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes bottom runner, covings, interconnecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Internal GI framework if necessary for support, Silicon Sealant (Clear/White/Winsel Gray), complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge
FALSE CEILING
Supply Installation Testing & Commissioning (SITC) of modular false ceiling with powder coated Galvanized Iron of 0.4 mm thick sheet on both sides, 50 mm thick class 'O' PUF of min.38kg/m3 density sandwiched in between. The surface shall be coated with 80-micron thick powder coating by hot dip galvanizing with zinc coating not less than 180gm/sqm both side of the panel. Scope includes runner, covings, interconnecting profiles, fixing arrangements, silicon sealant application and all other accessories required to complete the work as per site requirement. Internal GI framework if necessary for support, Silicon Sealant (Clear/White/Winsel Gray), complete with all necessary hardware, accessories, fittings and fixtures, as per description in individual items, technical specifications, drawings and instructions of the Engineer-In charge
PAINTING
Removing white or colour wash by scrapping and sand papering and preparingthe surface smooth including necessary repairs to scratches etc. complete
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of special primer applied @ 0.75 ltr /10 sqm
Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
STEEL WORK
Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes
Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
Providing at all heights, levels and locations 0.45 mm thick Galvalume sheet of Alloy 31500/31000/40800, conforming to IS 1254, IS 737, IS 2676. The sheet shall be fixed using self drilling/self tapping SS screws of size 5.5x65 mm with EPDM seal complete upto required pitch in horizontal, vertical or curved surfaces i/c cutting to size and shape where required as per the direction of Engineer-in-Charge. The rate shall be inclusive of all screws, seal, ridge, labour, scaffolding, machinery for fixing and approved sealant where required etc. but excluding the cost of purlins, rafters and trusses.
ELECTRICAL WORKS
SITC of 10 kVA, three phase input, Three Phase output, true<br>on-line UPS system with 30 mins back up standalone configuration, output isolation transformer buil-in, including all accessories, SMF batteries VRLA type with powder coated including all accessories cabling etc as required complete having following specification. Fully digital controlled based on DSP,<br>Power factor corrected from end > 0.9, Pure sine wave output, Full time output voltage & frequency regulation, Auto regulation of battery end voltage, Intelligent interface with LED/LCD display, Static bypass switch / manual bypass switch, Auto temperature compensation.<br>30 Min backup battery @ 10 kva Load Minimum VAH 10080<br>per ups (12v 42ah x20nos) SMF battery of reputed approved<br>make including open rack
SITC of 40A, 4P, Isolator in suitable sheet steel enclosure.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 16 sq. mm + 2 X 6 sq. mm earth wire
SUB MAINS
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
PLUG POINTS
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
Supplying and fixing following Universal( Multistrandard ) socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required.<br>6A/10/13A Multistrandard socket
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth,metal enclosed plug top along with 20 amps "C" curve, SP, MCB, in sheet steel enclosure, onsurface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
POWER CIRCUITRY
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required8 way (8+24) - three phase double cover (IP 42/43)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
TP MCB -40A SITC 40A TP C-Curve 10 kA MCB is a three pole highly durable MCB with finger touch proof terminals conforming to IP-20 degree of protection. It is used in Three Phase Supply to break the phase and the neutral is not the part of the MCB conforming to certification IEC 60947-2, mounting on symmetric rail EN/IEC 60715 or DIN 35 rail. made up of Halogen free plastic material, Large cable terminals of 35 Sq. mm capacity for better terminal.
CABLING WORK
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
EARTHING
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required
Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
LIGHT FITTING
2X2 SQUARE TYPE RECESS MOUNTED LED LIGHT<br>SITC OF 600mmX600mm square type Cool White, Warm White, Pure White LED light fixture with Integrated Driver & Backlight Technology with a minimum system efficacy of 95w/Lm, Standard CCT: 3000K*, 4000K & 6500K, high color rendering CRI >80, with high efficiency driver, minimum of 35000 hours working life, and Surge protection -4KV (light variant as decided by engineer in charge),including connection with existing point using suitable gauge copper conductor directly to the ceiling rose. Each module should be tested and QC approved by competent authority and the same to be furnished before electrical engineer HLL Lifecare limited before purchase or else any higher version approved by the Electrical Engineer HLL Lifecare Limited
UNFORESEEN WORKS
Charges for rectifying power supply issues of the Existing HVAC system complete as required as per the direction of HLL Electrical Engineer/ Engineer in charge. (General Labor works).
MASTERCELL TELECOM SERVICES (P) LTD
CHITHRANI TRADERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .