Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC PLOT NO 261 SHANTI KUNJ ALWAR 301415 RAJ | ALWAR | RAJASTHAN | 301415 | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.8 L+₹1.1 L (12.8%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Bedi Refrigeration Works L2 | RADHA ENTERPRISES L1 |
|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exceeding 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in Hard/Dense Soil complete all as specified and directed. | 105.75 | Cum | 120 ₹12,690 Lowest | 155 ₹16,391.25 |
| 2.00 | Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as specified and directed. | 53.6 | Cum | 30 ₹1,608 Lowest | 70 ₹3,752 |
| 3.00 | Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. | 52.13 | Cum | 30 ₹1,563.9 Lowest | 60 ₹3,127.8 |
| 4.00 | M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken complete all as specified and directed. | 38.07 | Cum | 700 ₹26,649 Lowest | 720 ₹27,410.4 |
| 5.00 | M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed | 4,087 | Each | 8 ₹32,696 Lowest | 10.5 ₹42,913.5 |
| 6.00 | Dismantling insulators any type, any size complete all as speified and directed. | 80 | Each | 5 ₹400 Lowest | 20 ₹1,600 |
| 7.00 | Dismantling of ACSR conductors, any size complete all as speified and directed. | 1 | Qtl | 500 ₹500 Lowest | 510 ₹510 |
| 8.00 | Supply, laying & testing IN REPLACMENT OF XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 4 core incl taking out old unsv cable from trenches all as specified and as directed.
Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately. | 300 | RM | 170 ₹51,000 Lowest | 185 ₹55,500 |
| 9.00 | All as item No 8 above but 25 Sqmm 4 core complete all as specified and directed. | 130 | RM | 250 ₹32,500 Lowest | 265 ₹34,450 |
| 10.00 | All as item No 8 above but 50 Sqmm 4 core complete all as specified and directed. | 340 | RM | 300 ₹1,02,000 Lowest | 410 ₹1,39,400 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
11 May 2026, 6:00 pmClosed
AGE I Lansdowne
Asst Garrison Engineer (I) Lansdowne, Disst- Pauri Garhwal Pin-246155
REPAIR MAINTENANCE OF LT UG CABLES, LT OVERHEAD LINES, PANEL AND OTHER CONNECTED WORKS AT ZONE I OF LANSDOWNE UNDER AGE (I) LANSDOWNE
2026_MES_760815_1
9193/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
All as per NIT and Tender Documents
6 documents required · 6 mandatory
₹500
AGE I Lansdowne
₹20,000
Yes
17 Jul 2026
18 Apr 2026
19 May 2026
20 Apr 2026
11 May 2026
4 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavation in trenches, not exceeding 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in Hard/Dense Soil complete all as specified and directed. | - | Cum | - | - |
| 2 | Returning filling in including spreading, leveling,watering and well ramming in layers not exc 25 cm in Hard/Dense Soil complete all as specified and directed. | - | Cum | - | - |
| 3 | Removing excavated material n.exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed. | - | Cum | - | - |
| 4 | M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken complete all as specified and directed. | - | Cum | - | - |
| 5 | M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed | - | Each | - | - |
| 6 | Dismantling insulators any type, any size complete all as speified and directed. | - | Each | - | - |
| 7 | Dismantling of ACSR conductors, any size complete all as speified and directed. | - | Qtl | - | - |
| 8 | Supply, laying & testing IN REPLACMENT OF XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 16 Sqmm 4 core incl taking out old unsv cable from trenches all as specified and as directed.
Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately. | - | RM | - | - |
| 9 | All as item No 8 above but 25 Sqmm 4 core complete all as specified and directed. | - | RM | - | - |
| 10 | All as item No 8 above but 50 Sqmm 4 core complete all as specified and directed. | - | RM | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
MakeList.pdf
Additional Documents • 0.49 MB
BOQ_852264.xls
BOQ • 0.32 MB
Tenderdocuments.pdf
Tender Documents • 0.70 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .