Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.7 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹1.0 Cr+₹2.9 L (3.00%)Rejected-Finance 20 SC BOSE COLONY GALL NO 2 DEFENCE LAB ROAD RATNADA JODHPUR 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Other than Lowest Bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Eligible Bidder. Does not satisfy eligibility criteria as per NIT for class B category a i and b i with respect to completion of requisite value of works and solvency. Also not submitted working capital certificate and EMD. |
Tender Value
Refer Docs
EMD Value
₹1.9 L
Closing Date
12 Oct 2020, 6:00 pmClosed
CWE (AF) CHILODA
CWE (AF) CHILODA MES PO CRPF CAMPUS VAYUSHAKTINAGAR GANDHINAGAR 382042
MODIFICATION OF HANGAR INCLUDING REPLACEMENT OF LT UG CABLES FROM SUBSTATIONS AT AF STATION VADODARA
2020_MES_372523_1
82044/CHL/E8
Open Tender
Civil Works
Works
365 days
BARODA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹1,000
GE (AF) BARODA
₹1.9 L
Yes
5 Nov 2020
27 Aug 2020
14 Oct 2020
27 Aug 2020
12 Oct 2020
30 Sept 2020
28 Aug 2020 - 22 Sept 2020
Amount
Dismatling floor, hearth or wall tiling including cement mortar bedding(but not backing), removing serviceable tiles to store and rubbish off the premises.
Dismantling plain or corrugated steel or Fibre sheeting, any gauge,any thickness, including nainital or similar pattern roof coverings
Dismantling of MS railing with hand rail of any description complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exeeding 1.5 m in depth and getting out in soft/loose soil for removing/laying of cable etc as directed.
Excavating in post holes in soft soil (or similar holes) each not exc 0.5 Cum, getting out, returiing filling and removing surplus soil to a distance not exc 50m and making good surface.
Returning, filling excavated soil in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each all as directed by Engr-in-Charge.
M&L Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed..
Removing surplus excavated soil to a distance not exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point.
M&L Cement concrete , 1:3:6, Type C2 (40mm graded aggregate) in foundations, filling and mass concrete.
M&L Providing cement concrete type B-0, 1:2:4 (12.50mm graded aggregate) as in levellng course to receive interlocking tiles complete all as directed.
M&L Forming jambs etc to openings including utting toothing and properly bonding into old work, also facing, jointing and pointing to match existing work built by cement mortar (1:4) complete all as specified and as directed.
M&L Cutting openings through brick walls built in cement mortar for door, window and other openings or enlarging existing opening for converting window into door openings etc or cutting out defective brick work for under pinning, including providing, fixing and removing shoring, cleaning and stacking bricks removing surplus serviceable brick, hard core, etc to store and rubbish not exc.50m complete all as specified and as directed.
S&F Aluminium(Extruded body) door closer hydraucally regulated designation No 3 universal type, suitable for door shutters of 851 to 1000mm in width and of weight between 61 to 89 kg and to floor complete all as specified and as directed.
M&L Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L Framed work as in doors or gates of angle or other section with gusset plates rails braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitings exclusive of steel sheeting or other covering running rails and guides and hanging also fastening and fixing complete.
S&F Anodised aluminium frame (powder coated with minimum thickness of powder coating 50 micron) for doors, windows, ventilaters or partition cubicles, etc with one or more rebates including joining cleat for fixing etc, complete all as specified and directed.
S&F Powder coated (minimum thickness of powder coating 50 micron) anodised aluminium doors shutters,partition, aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each doors, hinges, anodised aluminium snap beading screws, etc complete all as specified and directed.
S&F Stainless steel (Grade 304) as in railing all as specified and as directed.
S&F 2mm thick fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washers/ L-type or J type or corrugated hook bolts in roof or wall etc complete all as specified and as directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, chajjas, fixed with self tapping screws as specified.
M&L 10mm thick Makrana white Marble work (of any type) work table rubbed polished) in steps, jambs, strips, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L Machine cut kota stone slab flooring as in treads of stair, 20-25mm uniform thick including moulding for nosing and making two line on top and single piece for one tread, over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L Machine cut kota stone slab flooring as in riser of stair, 15-20mm, skirting,dado, and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L Vitrified tiles 10 mm thick (square , double charged) polished area of each tile exceeding 0.36 sqm but not exceeding 0.38 sqm as in floors set & jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M&L Vitrified tiles 10 mm thick (square rectangular , double charged) polished area of each tile exceeding 0.36 sqm but not exceeding 0.38 sqm as in skirting/dado set & jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block glossy finished any coloured with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade including dismantling of old paver block complete all as specified and as directed.
M&L 10mm thick rendering in CM 1:3 on fair faces of brickwork or concrete surface of walls/ vertical surfaces such as dado, skirting, etc as backing coat complete all as specified and as directed.
M&L Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed.
M&L Complete removal of existing treatment and applying two coats of oil emulsion distemper over a coat of alkali resistant priming paint over 2mm thick birla white cement putty on wall and ceiling complete all as specified and as directed.
M&L 5mm thick tinted glass complete all as specified and directed.
M&L Preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome complete all as specified and as directed
M&L Preparation of old painted cement concrete floor surface where existing painting to be removed to receive flooring system shall be abraded to a minimum of 150microns profile using shot/blasting/Scrapping complete The surface shall be shot-blast,diamond grinded or power scarified as required to obtain clean open porous concrete and to remove sufficient materials to provide a sound surface,free of resistance glaze efflorscence and any bond inhabiting curing compounds complete all as per manufactures instructions, as specified and directed.
M&L Preparation of old concrete floor surfaces having oil grease or other penetrating contaminants by treating with acid itching burning etc complete all as per manufacturer's instructions as as per manufactures instructions all as specified and directed.
M&L Preparation of new or old concrete surfaces free from oil grease or other penetrating contaminants by wire brushing blower etc complete all as specified
M&L Applying one coat of epoxy primer Nito prime 25 of FOSROC or other manufacturer's as given in list of makes and as per manufaturer's instructions.
M&L Racking out old expansion joint upto a depth of 40mm and inserting closed cell, medium density, cross linked polyethyene foam back up rod of 30mm dia, priming top 12mm depth with approved primer and filling with polyurethane based sealent all as specified and as per manufacturer's instructions
M&L Racking out old contraction/dummy joint and cleaning the joint with blower and treating for filling joints as under:- (a) Stage-1 Priming Providing and applying epoxy primer to the designated area with Nitoprime 25, a two part epoxy resin primer of FOSROC or other manufacturer's given in list of makes, supply pre-weighed units ready for on site mixing and application ready to recieve epoxy to the prime surface. (b) Stage-2 Joint Filling Providing and applying the epoxy resin screed Nitoflor TF5000 which shall be applied on epoxy primer whilst it is stacky of FOSROC or other manufacturer's given in list of makes, the tough screed shall be laid by trowel as a durable abrasion resistant screed at 3mm to 6mm thickness which on curing @ 30 degree centigrade, should achieve a compressive strenth of 90N/mm2 @ 1 day. 110N/mm2 @ 7 days when tested as per BS 6319 pt. 2, flexural strength of 40N/mm2 when tested as per BS 6319 pt. 3, Tesile strenth of 20N/mm2 when tested as per BS 6319 pt. 7. the maximum warp on the screed when tested as per IS 9162-1979 shall not exceed 0.24mm and the minimum value of notched izod impact strength shall be 34J/m when tested as per ASTM D256. Note: (i) Work shall be carried by authorised applicater of the manufacturer under manufacturer's supervision.
M&L High Strength Epoxy Underlay of Nitrofloor and Polyurethane Floor Topping of Nitroflor shall be provided with following steps (a) Providing and applying the high strength, self levelling, epoxy underlay flooring Nitoflor EU5 of FOSROC or other makes given in list of makes as an epoxy under lay of 3mm thickness on the designated area, the product shall be applied with V notch trowel and rolled by spike roller to release the entrapped air. the screed on curing @ 30 degree centrigrade should achieve a minimum compressive strength of 70N/mm2 @ 7 days when tested as per BS 6319 part 3 and tensile strength and tear strength of 12N/mm2 when tested as per BS 6319 part. (b) Providing and apply high strength plyurethane self leveling flooring SL 200UB of FOSROC or other makes given in list of makes as in floor topping with 2mm thickness in designated area, the product should be applied with V notch trowel and rolled by spike roller to release the entrapped air, the screed on curing @ 30 degree centrigrade should achieve a compessive strength of 65 N/mm2 @ 7 days when tested as per BS 6319 pt. 2. flexural strenth of 28 N/mm2 when tested as per BS 6319 pt. 3, tensile strength of 15N/mm2 when tested as per BS 6319 pt. 7. Note : (i) Testing of the flooring shall be done for tensile strength as per ASTM D412 and D624 respectively (ii) Work shall be carried by authorised applicator of the manufacture under manufacturer's supervision (iii) Testing of polyurethane item/joints filling materials shall be done as per IS/ASTM before incorporation of material in the work. (iv) A test patch suitable area as per manufacture's as advice of flooring shall be carried out before execution of work without any extra cost to department by the contractor and after getting approval from GE before the flooring work is under taken.
M&L 100 mm wide traffic guard colour line marking in two coats withTLPM paint over hangar floor after application of polyurethane based flooring Note :The paint shall be applied after 5 days of application of flooring
M&L 150 mm wide traffic guard colour line marking in two coats withTLPM paint over hangar floor after application of polyurethane based flooring Note :The paint shall be applied after 5 days of application of flooring
M&L 200 mm wide traffic guard colour line marking in two coats withTLPM paint over hangar floor after application of polyurethane based flooring Note :The paint shall be applied after 5 days of application of flooring
M&L Repair to Crack on pavement by Elastomeric Concrete shall be carried out as under : (a) Surface Preparation : Open the cracks till to get a sound based surface and space to have anchorages with elasomeric concrete(Flex O Patch) opening of the crack in any case should such that the prepared edge of the repair surface area should have 90 degree angle or obtuse angle with respect to the surface to have better anchorage.The prepared surface shall be free from all oils,grease,dirt,waxes heavy laitance and sharp edges.Sand blasting with medium girt sand is the preffered method of surface preparation.Mechanical grinding the surface is acceptable only when sand blasting is not possible.The surface should be prepared so as to add new profile to the concrete. (b) Priming : Prior to mixing and placing the elstomeric concrete, prime the substrates(s) coming in contract with the elstomeric concrete.Both vertical and horizontal surfaces should be primed with SPECIAL PRIMER RDL-942 of Chocksychemical or other Makes specified.The material should be applied using a paint brush and single coat. (c) Mixing and laying of elastromeric concrete :Kit contain 3Kg of part A and 1.5Kg of Part B with a 5.5 Kgs part of Part C(E-Crete Aggregate) using a drill and spiral mixing paddle premix A&B components unit uniform(approx 60-90 seconds).Immediately remove contents from Ç'and add to the above and continue mixing until no dry material appears.Once mixed the material can be poured into the block out/hoke white the primer is still wet.The material is self-leveling.Trowel finish as desired. Depth of elastomeric concrete = 50mm. Note :- (i) Use Xylene or Toluen as an Equipment cleaning solvent. (ii) Work shall be carried by authorised applicator under the manufacturer's supervision. (iii) Contractor will submit materrial testing certificate as per manufacturer instruction.
Taking down carefully copper/aluminium any type of sub main wiring and making good the disturbed surfaces of wall/floors/ceiling etc complete all as specfied & directed.
M & L Sub main wiring using two single core 6 Sqmm FRLS PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC Casing Caping/PVC Conduit accessories like bends, tee, etc fix on wall and ceiling and connecting to earth dolly and including 6 Sqmm earth wire, PVC insulated & unsheathed all as directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM.
M&L Sand cushioning to PVC cable using clean dry and natural river sand gently punning below/around cable complete all as specified Note : Punned thickness shall only be measured for payment
S & L Well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed.
Supply , laying and testing 300 Sqmm 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches ducts, pipe on walls, poles etc complete including taking down old UNSV Cable all as specified and directed.
Supply , laying and testing 150 Sqmm 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches ducts, pipe on walls, poles complete including taking down old unserviceable cable all as specified and directed.
Supply , laying and testing 95 Sqmm 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches ducts, pipe on walls, poles complete complete including taking down old unserviceable cable all as specified and directed.
Supply , laying and teasting 70 Sqmm 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches ducts, pipe on walls, poles etc complete complete including taking down old unserviceable cable all as specified and directed.
Supply , laying and testing 50 Sqmm 3.5 core XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade in trenches ducts, pipe on walls, poles etc complete including taking down old unserviceable cable all as specified and directed.
Supply and laying 50 mm bore pipe, light grade (ISI marked), galvanized iron with and including all fitting (ISI marked) laid in trenches/ fixed to wall/ fixed on pillars complete all as specified and as directed
M&L Boring of holes under road for insertion LT cable of up to 150 sqmm in 90 mm dia HDPE pipe pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including complete all as specified and as directed.
M&L High density polyethylene pipes (HDPE) 90 mm dia of pressure rating 6 kgf/cm2 laid in trenches for insertion of LT cable complete all as specified and directed.
S&F factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN DB) with metal door (IP-43 protection) fabricated from minimum 2.0 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB/TPN and ELM as incommer and outgoing MCBs as required at site complete all as specified and conforming to IS: 8623 along with cable end box complete all as specified and directed. NOTE :- (a) MCCBs and MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F 4 Pole MCCB 100 Amp, 50 Hz, 415 V with rupturing capacity 16 KA complete as in repairs all as specified and directed.
S&F MCB SP 6 to 32 Amps, 240 V, 50 Hz AC complete as in repairs all as specified and directed.
S&F Factory made epoxy polyester powder coated distribution board SP & N 12 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 100 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and outgoings MCBs complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB complete as in repairs all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F MCB SP & N 63 Amps, 240 V, 50 Hz AC complete as in repairs complete all as specified directed.
S&F Bus bar chamber (800x500x350mm) out door type fabricated from 3.15 mm thick CRCA sheet duly welded and painted with one coat of red oxide and two coats synthetic enamel paint front & back door opening with locking arrangement RYBN with aluminium bus bar (suitable upto 400A), 25x3.15mm with insulator, nut & bolt one incomming the aluminium U/G cable and one out going aluminium conductor under ground cable with angle iron stand 300mm height including PCC form work completed all as specified and directed.
Supply, install testing and commissioning weather and vermin proof AMF panel factory fabricated outdoor type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron frame of MS angle 40 X 40 X 6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required Nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly powder coated (15 micron) grey hammer tone with one coat AMF Panel Outdoor type for 200 KVA DG with 315 Amp contactor and MCCB 315 Amps 3 pole for incoming and outgoing and thermal over load relay Microprocessor based AMF Module incorporating supply failure timer , restoration timer 3 implulse automatic engine start/ stop logic mains/generator voltage and frequency sensing ,Multifunction Meter with scrolling reading for fault indication LED Type Electronic KWH counter display battery charger, control wiring of VMR with angle iron stand 300mm height including PCC form work complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate, electrode, 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia unto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate, electrode, 600x600x6.3 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth strip 32x6mm by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 50mm dia unto 7.5 from the earth plate electrode & refillling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed
S&F Aluminium strip 25mm x 3.15 mm complete with saddles and fixing screws for fitting the strip complete as in repairs all as specified and directed.
S&F DOL starter CE certified for 7.5 HP motor 415 V, 50 Hz capacity and IS-13947-4-1 complete as in repairs all as specified and directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hex. head screw complete as in repairs all as specified and directed.
S&F Beam Master Detector Transceiver type for detection up to 50meter length complete all as specified and directed.
S&F Fire alarm hooter/ Siren electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120 DB measured at 1.5 meter with sound output variation of + 5 DB for 500 meter range complete all as specified and directed.
S&F Conventional type 4 zone Fire Alarm control panel with battery backup complete all as specified and directed.
S&F Glass break manual call point complete all as specified and directed.
Supply and laying PVC armoured 1.5 sqmm 2 core FRLS copper cable complete all as specified and directed.
M K ENGINEERS CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .