Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹12.2 LAccepted-AOC 234 4 JC BOSE ROAD KOLKATA | KOLKATA | WEST BENGAL | 700001 | L-1 | Accepted-AOC Being L1 | |
| 2 | L-2₹13.5 L+₹1.2 L (9.93%)Rejected-Finance R N COLONY PO BIRPARA DIST ALIPURDUAR W B PIN 735204 | ALIPURDUAR | WEST BENGAL | 735204 | L-2 | Rejected-Finance Being L 2 | |
| 3 | L-3₹13.6 L+₹1.3 L (10.8%)Rejected-Finance | L-3 | Rejected-Finance Being L 3 | |
| 4 | L-4₹13.7 L+₹1.5 L (11.9%)Rejected-Finance 17 BIPIN GANGULY ROAD KOL 30 | L-4 | Rejected-Finance Being L 4 | |
| 5 | L-5₹13.8 L+₹1.6 L (12.7%)Rejected-Finance GAIRKATA ROAD POST BINNAGURI PIN 735 203 DIST JALPAIGURI W B | JALPAIGURI | WEST BENGAL | 735203 | L-5 | Rejected-Finance Being L 5 |
Tender Value
₹20 L
EMD Value
₹50,000
Closing Date
27 Jan 2020, 6:00 pmClosed
GE North Binnaguri
Dist Jalpaiguri West Bengal
PERIODICAL SERVICES AND INTERNAL WIRING TO OTM ACCN AT CENTRAL ZONE UNDER GE NORTH BINNAGURI
2020_MES_313716_1
NIT No . 8701/359/02/E8 20190-2020
Open Tender
Miscellaneous Works
Item Rate
180 days
BINNAGURI
Class E Category ai
8 documents required · 8 mandatory
₹500
Yes
GE North Binnaguri
₹50,000
Yes
28 Mar 2020
10 Jan 2020
29 Jan 2020
10 Jan 2020
27 Jan 2020
22 Jan 2020
Amount
SCHEDULE A CIVIL WORKS Material and labour for preparation of old plastered or unplastered surfaces of walls by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc., of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of colour wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old decorated distempered surfaces of walls by washing, rubbing down and stopping of old decorated surfaces and distempering walls by applying one coat of acrylic based distemper emulsion of any tint/shade complete all as specified.
Material and labour for preparation of old decorated surfaces of walls by washing, rubbing down and stopping of distempered and painted surfaces and applying one coat of cement base paint of any tint/shade including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for one coat of exterior emulsion paint 100% acrylic, white or tinted on old painted surfaces of wall/chajja//facias including prepration of old surfaces and washing floors, cleaning glass, joinery,electrical fittings, wiring etc., of drops and splashes complete all as specified .
Material and labour for preparation of old painted wooden /wood based materials surfaces of any description, not otherwise described, over 10 cm width or girth and painting one coat with synthetic enamel paint (1st quality) including cleaning, stopping and rubbing down and removing all dropings etc. all as directed.
Material and labour for preparation of old painted steel and iron surfaces of any description , not otherwise described,over 10 cm width or girth and painting one coat with synthetic enamel paint including cleaning, stopping and rubbing down and removing all drops etc. complete all as speciified.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc. including removing rubbish material from work site complete all as specified.
Material and Labour for rendering 15 mm thick on fair faces of brick or concrete surfaces finishing surfaces even and smooth without using extra cement in Cement mortar 1:6 all as specified and directed.
Material and labour for rendering 10 mm thick on concrete surfaces in ceiling, fair surfaceas as in soffit of slab, beam column , finished without using extra cement in cement and sand mortar 1:3 complete all as specified
Material and labour fo preparation of new plastered or unplastered surafces of wall and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour fo preparation of new plastered or unplastered surafces of ceilings and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for rendering 15 mm thick (10+5) in two layers on fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions (WPC shall be apply in second layer and measured and paid separately) complete all as specified top surfaces finished even and smooth without using extra cement complete all as specified.
Supply only Integral liquid water proofing compound conforming to IS-2645-2003 complete all as specified.
Material and labour for preparation of new/untreated surfaces/ of walls and applying applying two coats of colour wash over a coat of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
INTERNAL ELECTRIFICATION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Material & Labour for consealed type point wiring with 1.50 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable of working voltage 1100 volts grade conforming to IS-694 Pt I & II of 2000 drawn through and including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification), including provision of 1.5 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable as earth continuity conductor, connected to main switch / DBs or common earth dolly for one light / ceiling / exhaust fan point / bell push button point controlled by one 5 Amps one way switch complete all as specified and as directed for light /fan point controlled by one way switch 5/6 amps. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.18 here-in-before but for one socket out let 5/6 amps point on the independent board
All as per item No.18 above but One socket out let 5/6 amps point on the same board complete all as specified.
All as per item No.18 above but One light point controlled by two way switch 5/6 amps.
Material and labour concealed wiring for 5/6 pin 6/16 Amp switch socket combination on independent boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FR earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface n exc 15 cm girth complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, two ways complete all as specified.
Supply and fixed socket 2 in 1, 5 Pin, 5/6 amps, any type complete all as specified and as directed.
Supply and fixed switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed switch piano flush type, single pole , 15/16 Amps, one way complete all as specified.
Supply and fixed in repairs switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, of any type complete all as specified.
Supply and fixed switch in repairs socket combination 2 and 3 Pin, 5/6 amps, multipurpose of any type flush type controlled by one switch complete all as specified.
Supply & fixed Bell push , flush type , 5/6 amp complete all as specified.
Supply & fixed Buzzer, Ding dong, AC 230 Volts, single pole 230 volts all as specified and directed.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings including LED white glass Lamp 1x14 Watts, 230V Base-22 complete all as specified.
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
Supply and fixing in repairs of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 double side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed. Make : Havells Cat No: REGALBATTEN8 UPTO 1 x 22W SSBSWH & Cat No: PHOTONULTRA 1213T8 SSTL20W LED 865 SPC (Tube) or of equivalent make as specified in list of makes
Supply and fixing in repairs LED tube light fittings 1 x 9/10 watts energy efficient, 230 V incl 1x9/10 watt LED tube, surface / wall mounted LED batten with aluminium housing and integrated driver including holders, connector block etc. complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable all as specified and directed. Make : Havells Cat No LUMILINEPLUSBS10WLED865SPCSS or of equivalent make as specified in list of makes
Supplying and fixing in repairs two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC rigid non metallic conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note :-(i) Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item). (ii) Two run of sub main wiring cable along with one run of earth wire and one run of PVC Conduit / casing and capping shall be measured as one length]
Supplying and fixing in repairs two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including nd including suitable size PVC rigid non metallic conduit (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified. Note :-(i) Cutting chases for conceal conduit in walls / ceilings and making good to match with the existing surface shall be deemed included in unit rate of this item). (ii) Two run of sub main wiring cable along with one run of earth wire and one run of PVC Conduit / casing and capping shall be measured as one length]
Supply and fixed in repairs for Single pole and neautral enclosure with a two pin and earth plug and socket complete with one single pole MCB, 20 Amps, 240 Volts, including necessry connection complete all as specified including taking down old one
Supply & fix sheet metal enclosure for 12 way Distribution Boards (DB’s), double door , single pole and neutral with 200 amps rated bus bar, including bus bar neutral link, earth bar and din rail, IP-43, IK-09 protection including gasket and door earthing suitable for fixing MCBs/isolators fixed on wall surface and making good the disturbed surfaces of wall and connecting up including taking down old unserviceable one complete all as specified and as directed.
Supply and fixed in repairs MCB SPN 5-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 40 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
M/S NIKITA ENGINEERING CO
M/s. RAMPHAL GARG
M/S DUTTA ENTERPRISE
M/S VIRENDRA KUMAR SINGH
BBKundu
Shri Amarnath Sah
samrat saw mill and joinery workshop
M/S BIG BEN ENTERPRISES
SINHA ENTERPRISE
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .