| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.5 LAccepted-AOC 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L1 | Accepted-AOC After deduction of Sch of credit 1,92,973.50 | |
| 2 | L2₹31.3 L+₹1.8 L (6.26%)Rejected-Finance GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.7 L+₹3.2 L (11.0%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L3 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S BHATT ENTERPRISES L3 | M/S NAYAL ELECTRICALS L2 | shahji contractors L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and errecting in true vertical position steel tubuler poles 11 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-55 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed | 4 | Each | 25,000 ₹1,00,000 Lowest | 29,680 ₹1,18,720 | 29,000 ₹1,16,000 |
| 2.00 | S&F HT disc type porcelain vitreous white, brown or green insulator size 145mm high and 255mm dia ball and socket type for two in series assembly with tension clamp for conductor for working pressure 11000 volts complete all as specified and directed. | 20 | Each | 1,100 ₹22,000 | 485 ₹9,700 | 300 ₹6,000 Lowest |
| 3.00 | S&F pin type porcelain vitreous white, brown or green insulator size 150mm high and 150mm dia, for working pressure 11000 volts grade incl one galvanised mild steel spindle, two galvanised iron washers and one nut complete all as specified and directed. | 20 | Each | 500 ₹10,000 | 385 ₹7,700 | 150 ₹3,000 Lowest |
| 4.00 | Supply fixing and testing in replacement Lightening arrester non linear registor type comforming to IS 3070 Part I complete line with all fittings Transmision class, discharge class-2 nominal discharge current 10KA & high discharge 100 KA assembly suitable for 11 KV incl clamps, nuts, bolts & washers & connecting to earth with 4mm dia GI wire all as specefied and directed | 12 | Set of Three | 8,722 ₹1,04,664 | 5,630 ₹67,560 | 3,500 ₹42,000 Lowest |
| 5.00 | M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed. | 2.5 | Qtl | 12,000 ₹30,000 | 9,225 ₹23,062.5 | 7,500 ₹18,750 Lowest |
| 6.00 | Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 200 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity 10 Amp.complete with DO fuses assambly with one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge. | 8 | Each Set | 16,000 ₹1,28,000 | 15,830 ₹1,26,640 Lowest | 20,000 ₹1,60,000 |
| 7.00 | Supply, laying, jointing and testing HT XLPE cable , of sizes 95 sqmm, 3 core 11000 V screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc complete all as specified and directed. | 350 | RM | 1,200 ₹4,20,000 | 1,029 ₹3,60,150 Lowest | 1,105 ₹3,86,750 |
| 8.00 | All as per item no 7 here in before but, size of caple 120 Sqmm, 3 core | 350 | RM | 1,300 ₹4,55,000 | 1,237 ₹4,32,950 Lowest | 1,305 ₹4,56,750 |
| 9.00 | M&L outdoor type cable end terminatrion kit, cold shirnkable jointing material and accessory complete suitable for 11 KV HT XLPE underground cable size 95 sqmm 3 core including excavation /returning filling work,testing after jointing complete all as specified and directed. | 8 | Each Job | 9,000 ₹72,000 Lowest | 9,700 ₹77,600 | 12,500 ₹1,00,000 |
| 10.00 | M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 sqmm to 95 Sqmm 3 core and conforming as per IS 13573 OF 1992, cold shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type including excavation /returning filling work compelete all as specified and directed. | 4 | Each Job | 16,500 ₹66,000 Lowest | 19,600 ₹78,400 | 19,990 ₹79,960 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
29 Jul 2025, 6:00 pmClosed
CWE (HILLS) PITHORAGARH
HQ CWE (HILLS) PITHORAGARH POST OFFICE - BHARKATIA DISTRICT - PITHORAGARH STATE - UTTARAKHAND PIN 262520
CA NO. CWE/HILLS/RKT/28 OF 2025-2026 REPAIR/MAINT OF EXTERNAL ELECTRIFICATION HT SYSTEM AT RANIKHET, CHAUBATIA, ALMORA AND KAUSANI UNDER GE RANIKHET
2025_MES_716945_1
89220/25-26/E8
Open Tender
Civil Works
Item Rate
120 days
RANIKHET
Class - D
9 documents required · 9 mandatory
₹500
GE (MES) RANIKHET
₹80,000
Yes
18 Sept 2025
26 Jun 2025
5 Aug 2025
26 Jun 2025
29 Jul 2025
10 Jul 2025
Amount
Supply and errecting in true vertical position steel tubuler poles 11 meter long complete with M S base plate , MS pole cap, bolts nuts & screw as specified type 410 SP-55 with and including painting of poles with black bitumenous paint throughout the length internally and outside upto planting depth and remaining portion 2 coats of aluminium paint over a coat of red oxide primer, complete all as specified and directed
S&F HT disc type porcelain vitreous white, brown or green insulator size 145mm high and 255mm dia ball and socket type for two in series assembly with tension clamp for conductor for working pressure 11000 volts complete all as specified and directed.
S&F pin type porcelain vitreous white, brown or green insulator size 150mm high and 150mm dia, for working pressure 11000 volts grade incl one galvanised mild steel spindle, two galvanised iron washers and one nut complete all as specified and directed.
Supply fixing and testing in replacement Lightening arrester non linear registor type comforming to IS 3070 Part I complete line with all fittings Transmision class, discharge class-2 nominal discharge current 10KA & high discharge 100 KA assembly suitable for 11 KV incl clamps, nuts, bolts & washers & connecting to earth with 4mm dia GI wire all as specefied and directed
M&L for MS cross arms bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts and washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply, installation, commissioning and testing of switch Air break, Gang operated with 12 insulator switch Triple pole mechanicaly operated, mounted on insulator and steel frame, with mechanism worked from ground level, for current rating 200 Amp operating Voltage 11 KV out door type vertical mounted type complete with locking arrengement,assembly with fuse mount carrier and fuse element of required capacity and isolate suitable for 11 KV including necessary electric connection and 11 KV fuse (drop out type) of capacity 10 Amp.complete with DO fuses assambly with one No. operating Rod of 25 mm dia bore grade GI pipe of suitable length worked out from ground level and handle complete with lock and two Nos keys incl flat iron clamp 50mm x 6mm MS channel of suitable size & length for fixing GOD incl nut,bolt, washers including taking down existing set all as directed by Engineer-in-charge.
Supply, laying, jointing and testing HT XLPE cable , of sizes 95 sqmm, 3 core 11000 V screened, PVC 'E' grade insulated bedded, galvanised steel (heavy duty ) strip or wire armoured with alluminium conductor 11 KV pressure earthed system conforming to IS 7098 (Part-1 ) 1977 and Part-II of 1985 laid in pipes /ducts/ trenches,under floor and roads or fixed to wall etc complete all as specified and directed.
All as per item no 7 here in before but, size of caple 120 Sqmm, 3 core
M&L outdoor type cable end terminatrion kit, cold shirnkable jointing material and accessory complete suitable for 11 KV HT XLPE underground cable size 95 sqmm 3 core including excavation /returning filling work,testing after jointing complete all as specified and directed.
M&L cable straight through joint box type suitable for 11 KV U/G XLPE screened PVC bedded GI Strip or wire armoured cable size 50 sqmm to 95 Sqmm 3 core and conforming as per IS 13573 OF 1992, cold shrinkable, , termination kit jointing material connected to electrical system with and including cable pieces of suitable size length, and the tap vice type including excavation /returning filling work compelete all as specified and directed.
All as per Item no 10 here in befoe but for size 120 sqmm to 185 sqmm.
M&L for stringing and stretching (ACSR) conductor on HT/LT over head line including binding on insulator with aluminium binding wire or aluminium trap for (Weasel) 6/1x2.59mm aluminium and 1x2.59 steel/ Ferret (6/1 x 3.0 mm aluminium and 1 x3.0 mm steel), compelete all as specified and directed.
M&L stay assembly complete comprising of 7/3.15 galvanised stranded stay wire of required length fixed to pole with and including FI clamps 50 x 6 mm size bolt, nuts washers, GI steel stay rod 20 mm dia and 1800 mm long stay bow 400 x14mm, GI steel plate 300x300x6mm, two nos thimble loop insulator of size 90x140mm clearance hole 16mm including two coats of aluminium paint over a one coat of red oxide primer on exposed mild steel work as shown in electrical plate No. 1 of SSR part - I 2009 complete all as specified and as directed.
Supply and laying in replacement GI steel tubing light grade (IS-1239) of size 80mm with all fittings in trenches/under roads/along pole/wall for protection of Cable/GI wire/ GI strip etc all as specified and directed. (Note : Excavation and earth work shall be measured and paid separetely)
All as per item No. 14 here in before but size of pipe 100 mm dia
M&L for earthing complete with galvanised steel, earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in in electrical plate No 5 on page 19-49 of MES schedule 1991 Part I connected to main switch board /main DBs/ earthing test point Including all necessary excavation and earth work in hard/ dense soil common salt and charcoal dust mixed and packed 150 mm thick all-round the GI earth plate, watering pipe 20 mm dia G I medium grade . GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150C/C both ways and pit/ chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 25mm dia light grade up to 7.5m from complete all as specified, indicated on electrical plate No 3 and as directed incl testing on completion. NOTE: (i) Earth lead beyond 7.5 m from electrode to earth terminal GI pipe light grade 25mm/40mmdia for protection against mechanical damage to lead shall be measured separately (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone at no extra cost.
All as per item No. 16 here in before but with GI earth strip 32x6mm by means of nut, bolts, check nuts, washers of GI steel 40mm dia light grade 1.5 mtr long watering pipe with one socket and plug on top and 40mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr incl PCC chamber RCC cover with lifting handle, layer of charcoal & salt including necessary excavation & earth work all as shown in EP No 3 connected to earthing test point all as specified and directed.
All as per item No. 16 but using copper plate 600mm x 600mm x 3.15mm thick electrode and copper strip 20x3mm by means of nut, bolts, check nuts, washers of GI steel 40mm dia light grade 1.5 mtr long watering pipe with one socket and plug on top and 40mm dia GI pipe light grade for protection of earth strip upto a length of 7.5 mtr incl PCC chamber RCC cover with lifting handle, layer of charcoal & salt including necessary excavation & earth work all as shown in EP No 3 connected to earthing test point all as specified and directed.
M & L for one coat of aluminium paint of approved quality including preparation of existing old painted surface of steel tubular pole HT complete including flat iron clamps, bracing , cross arms etc and numbering of poles with white synthetic enamel paint over a circular painted base complete all as specified and directed.
Tightening/restringing existing loose/broken conductor ACSR/copper any type or size incl binding with suitable binding wire and jointing jumpers as required at site all as specified and directed.
Tightening and restringing existing loose/broken continuous GI wire 4 mm dia on existing HT over head lines including stringing all as required at site complete all as specified
Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for post holes, laying cables and getting out including jointing bottom surface to the reqd level/slope etc complete all as specified and directed.
Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and exc 1.5 mt but n. exc 3mt in depth for post holes, laying cables and getting out including jointing bottom surface to the reqd level/slope etc complete all as specified and directed.
Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil all as specified and directed.
Removing excavated material to a distance not exc 15 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point.
M&L for laying of fine river sand, free from sharp material for cable cushioning in trenches all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class HV type I flat of size 300mm x 180mm x 40mm all as specified factory made ISI marked.
M & L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of steel tubular pole incl form work complete all as specified and directed.
M & L for PCC (1: 4:8 ) type D-2 using 40mm graded stone aggregate as in bottom of pit for bed concrete of steel tubular pole incl form work complete all as specified and directed.
M & L for PCC ( 1:2:4) type B-1 using 20mm graded stone aggregate as in coping including all form work complete all as specified and directed.
Dismantling of existing HT pole any size/type from foundation in necessary earth work including dismantling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.
Dismantling of cross arms, fabricated from Ms structural section of any type and size, duly bolted from existing position and keeping at side for repair/replacement as directed.
Taking out old unserviceable HT cable any size from treanch/wall/pole etc including protection cover all as directed by Engr-in-Charge.
Dismantling of existing stay assembly any type/size from its stay rod, cutting stay rods (above ground portion) dismantling MS clamps, nuts, bolts, stay bow, loop insulators, stay wire etc complete all as specified and directed.
Dismantling/taking out old ACSR/copper conductor/GI earth wire any size from existing over head lines incl disconnection all as specified and directed.
Dismantling/taking out insulator of any size/type from existing electric HT lines all as specified and directed.
Cutting/ Trimming of trees/branches from HT/LT overhead lines /pole of any width/ girth clearing 2 meter horizontal 7.2 meter vertical distance from both side of conductor including collection and shifting the retrieved timber from site at a place as directed by Engr-in-charge complete all as specified and directed. Note :- (i) Each span have a distance 40mtr approximately (ii) All cutting branches of trees shall be thrown away/ burnt at approximate 200 to 500 mtr away as directed.
M&L for danger notice plate of 1.6 mm thick mild steel sheet, vitrous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT 25 x 20 cm complete incl taking down old danger plates all as directed at site.
Supply and fixing in replacement of HT jumper of existing two/four pole structure of transformer etc includinng using jumpers made out of HT XLPE cable 11 KV, including PG clamp nut, bolts, thimbles and washers etc as required at site all as directed by Engr-in-Charge.
M&L for disconnecting of defective transformer (indoor/outdoor) type 11/433 KV copper wound from power mains and dismantling the same from 2/4 pole structure/plateform mounted substation at site and opening for removing of the unserviceable parts i.e. bushing, bushing rod, stud, lugs, nut & bolts as required and re-assembling after carrying out required repair and installation on existing 2/4 pole structure/plateform with neccessary arangements including connecting up electricallly, commissioning and testing all as directed by Engr-in-Charge and specified in particular specification of the following capacity :- (a) 25 KVA to 500 KVA Note : U/S, worn out items required replacement shall be measured and paid separately under respective items of Sch.
M&L for HT porcelain bushing complete with brass finned copper rod with nuts & bolts, gasket complete including taking down old bushing for 25 KVA to 160 KVA capacity transformer complete all as specified and as directed.
All as per item No. 41 here in before but capacity of trasformer 250 KVA to 500 KVA
M&L for LT porcelain bushing complete with brass/tinned copper rod with nuts/bolts and gasket set for 25KVA to 160KVA capacity of transformers including taking down old bushing complete all as specified and directed.
All as per item No. 43 here in befoe but capacity of transformer 250 KVA to 500 KVA
M & L for Painting of transformer of capacity 25 KVA to 100 KVA by apply two coats of synthetic enamelled paint of grey colour by spray painting complete including prepration of old surfaces by removing dust, oil, grease etc all as specified and directed by Engr-in-Charge.
All as per item No 45 here in before but capacity of transformer above 100 KVA
M & L for packing the silica get to bring it to required blueish colour and re-filling the new Silica gel in to the breather complete all as directed.
M & L for Dehydration /filtration of transformer oil of existing transformer/ OCB installed at site with portable plant to improve the dielectric strength 45 to 60 KV during filling after initial filtration including testing of dielectric strength after dehydration at site.
Supply & filling in replacement of transformer oil in transformer in situ/ at site for toping up the level of oil having dielectric strength 40-60 KV during filling after initial filtration conforming to IS-335 all as directed at site by Engr-in-Charge of Make : Power/Insole/Universal (Transformer oil shall be supplied in sealed container)
Supply and fixing breather suitable for transformer complete all as specified and directed.
M & L for Anti-climbing device,spikes type fabricated out of M.S bars (round, square and flat) including nut, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified
Supply and fixing in replacement HT cable/route indicator cast iron of suitable size along HT cable trench including planting in ground with PCC complete all as specified and directed.
M&L stringing and stretching galvanised steel wire 4 mm dia for guard wire of HT/LT over head line incl binding on insulator with aluminium binding wire or aluminium trap compelete all as specified and directed.
M&L for calibration (all connections and Mechanism) cleaning servicing overhauling testing complete of 11KV VCB(SF6) as mentioned below: a). Taking out incoming and outgoing HT 11 KV 3 core cables from the electric system and calibrating the CTs of each VCB(SF6) with the help of primary injection kit and testing it for proper tripping system in presence of Engr-in-charge and reconnecting the incoming and outgoing HT cables complete in panels. b). Taking out overcurrent relay 02 Nos and Earth fault relay 01 No and calibration of relays with the help of secondary injection kit,and proper setting of relays and refixing back in existing positions testing of proper tripping system in presence of Engr-in-charge c). Inspecting, servicing and checking all connections of control winding, proper availability of supply AC/DC, incoming and outgoing connections and tightening them, cleaning the contacts and terminal with CTC solution and using the blower for dusting complete testing it making VCB set trouble free service in full satisfaction of Engr-in-charge and inclusive of one primer coat with red oxide one under coat , one finshing coat with aluminium paint complete all as specified and directed d) Repair/replacement of defective bus bar-3 Nos and PT bushing-3Nos d). All the instruments, primary and secondary injection kit and T&P required for the above job shall be arranged by the contractor at site and cost of the deemed to be included in the quoted rates.
Supply & Fix in repair PT Fuse for 11KV HT panelsVCB(SF6) for incoming/ outgoing with connecting accessories complete all as specified and directed.
Removing of old U/S relays of HT VCB/SF6 including supply & fixing of relay system in existing HT VCB panel complete with self powered microprocessor based programmable over current and earth fault relay, with self check facility, with programmable characteristics and data storage feature. as per exixting sample including calibrating and inspection and testing complete assembly all as specified and directed.Make ABB/Crompton/Ashida/Areva
Opening up the top cover of transformer and taking out the transformer Oil in a separate container after disconnecting the HT/LT side electric connections from both the primary & secoundary side of the transformer of any type/description (indoor/out door type) installed on pole/floor, for carrying out necessary repair/rewinding to HT/LT side after shifting the transformer to contractors work shop including taking out complete core assembly, Megger the defectivewinding portion/taking out ,cleaning the laminated core and rewinding with appropriate guage/winding wire/strip winding of existing, description for transformer of capacity above 100 KVA to 500 KVA/including assembling & testing on completion & installation the same at the site all as specified and directed by the Engineer-In-Charge,. Note:- 1. Winding of coil shall be measured and paid separately under respective item. 2. Transportation chagres are inclusive in the quoted rates. 3. The cost for the dehydration of transformer oil if required shall be measured and paid separately. 4. The cost of insulation material such as paper,cotton tape, latheriod sheet, cork sheet etc are inclusive in the coated rates.
All as per Item No 58 here-in-before but capacity 50 to 100 KVA.
Supply only copper winding wire of any size/description suitable for step down transformer of any capacity, including winding of coils (HT) as per the manufactures design & specification to obtain rated KVA complete all as specified and directed.
All as per item No 60 above but for strip winding for LT side.
M&L for temparature guage 0 to 125 degree C with transformer installed at site with all accessories complete all as specified and directed by Engineer-in-Charge.
Supply & fix drain valve for transformers upto 250KVA complete all as specified and directed.
Supply & fix drain valve for transformers with capacity more than 250KVA and upto 500 KVA complete all as specified and directed.
Supply and Fix HT insulation tapes ISI Marked for terminating high voltage cables for insulation sealing of connection of wire and cable for bus bar insulation, transformer terminal insulation etc complete all as specified and directed.
Supply and Fix HT DO fuse of following capacity 10 Amp
All as per item no 66 here in before but capacity 20 Amp
All as per item no 66 here in before but capacity 30 Amp
All as per item no 66 here in before but capacity 40 Amp
All as per item no 66 here in before but capacity 50 Amp
Supply and fixing fire retardent rubber mat of 1 Mtr x2 Mtr x19 mm having insulation capacity of 33 KV.
S & F guard cradles, make to shape, hexagonal / rectangular or any other shape directed by Engineer-in-charge, fabricated out of 4 mm dia GI wire including 14 SWG binding wire, MS channel, clamps as required and directed complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping of pole / floor/plinth finished fair and even complete all as specified and directed.
M & L for loose filling with aggregates of gauge 40 to 80 mm in soakage pits, substation premises, soakage well etc to the required level all as specified and directed
Fixing only chain link fencing including line wire, any mesh type of standard rails straining bolts etc., including provision of binding wire complete all as specified and directed. Note: Chain link mesh shall be supplied and measured under relevant item of schedule
Supply only chain link mild steel galvanised fencing (with mesh size 50x50 mm and dia 3.8mm )complete all as specified and directed.
S & F MS posts and struts in fencing including cutting tops to shape as directed, notching to shape for securing wire mess etc, drilling holes, flat iron fillets including all necessary drilling,riveting/bolting etc and similar work conforming to Fe 290 Gde E-165 complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (40mm graded aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M & L for mild steel round bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for preparation of new steel and iron surfaces of any description and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screw both ends; each screwed end to be fitted with washers and one hexagonal or square nut, bolt 100 mm long & Diameter of neck in mm Exc 100mm n exc 150mm complete all as specified and directed.
Excavation in post holes (or similar holes) each n exc 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around ,in layers not exc 25 cm , in any type
M/S NAYAL ELECTRICALS (BID ID -3376024)
M/S BHATT ENTERPRISES (BID ID -3369549)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .