Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.0 LAdmitted-Finance MAALGODAM ROAD FURNITURE MARKET HALDWANI 263139 DISTT NAINITAL UTTARAKHAND | HALDWANI | NAINITAL | UTTARAKHAND | 263139 | ₹10.0 L | L1 | Admitted-Finance |
| 2 | L2₹10.1 L+₹9,894 (0.99%)Admitted-Finance CHAMUNDA VIHAR RAMNAGAR ROAD KASHIPUR CAPITAL | ₹10.1 L+₹9,894 (0.99%) | L2 | Admitted-Finance |
| 3 | L3₹10.1 L+₹17,714 (1.78%)Admitted-Finance KHASRA NO 203 KHARAKPUR DEVIPURA KASHIPUR | KASHIPUR | ₹10.1 L+₹17,714 (1.78%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | UTTARANCHAL ENGINEERS L1 | KUMAUN ELECTRICALS L3 | M/s Bharat Construction and Trading Company L2 |
|---|---|---|---|---|---|---|
| 1.01 | Maintenance work of Hydrant/HVW pump of capacity 410 CU.M/hr at 70 MWC Head/1488 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | 53,931 ₹1,07,862 Lowest | 54,600 ₹1,09,200 | 54,250 ₹1,08,500 |
| 1.02 | Maintenance work of Diesel engine driven stand by pump of capacity 410 CU.M/hr at 70 MWC Head/1500 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | 48,960 ₹97,920 Lowest | 49,100 ₹98,200 | 49,360 ₹98,720 |
| 1.03 | Maintenance work of Jockey Pump of capacity 10.8 Cu.M/hr. at 80 MWC Head/2920 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | 41,911 ₹83,822 Lowest | 42,400 ₹84,800 | 42,570 ₹85,140 |
| 1.04 | Maintenance work of sluice valve of inlet header and outlet header all size valves works include maintain packed with non asbestos fibbers gland. glands are internally lubricated, corrosion inhibiter prevent for spindle damage and maintenance for spindle and gland pusher ser on zero leakages. | 2 | No. | 41,961 ₹83,922 Lowest | 42,500 ₹85,000 | 42,310 ₹84,620 |
| 1.05 | Cleaning of Hose boxes, panel, equipments, water storage tank once in a month. checking and rectifying hose, hydrant valves, pressure switch and solenoid valves, spray nozzle, deluge valve and push button piping throughout the switchyard for any leaks attending/ repairing. | 2 | No. | 33,970 ₹67,940 Lowest | 34,800 ₹69,600 | 34,120 ₹68,240 |
| 1.06 | Maintenance of annunciation panel of hydrant system, checking and testing fire alarm detection system and rectifying the abnormal function of the system by repairing defective component, card of the system and defective smock detectors. | 2 | No. | 46,471 ₹92,942 Lowest | 46,900 ₹93,800 | 46,580 ₹93,160 |
| 1.07 | Maintenance work of air vessel, diesel tank, A.c. distribution board, D.C. distribution board, battery charger, alarm system associated wiht fire fighting system as per site requirements. Testing all pumps D.G. set, panel, replacement of any faulty parts for proper operation of equipment also connection tightening all of all terminals. | 2 | No. | 36,961 ₹73,922 Lowest | 37,500 ₹75,000 | 37,290 ₹74,580 |
| 1.08 | Tightening of all nuts-bolts of flangers, joints in the whole pipe line of the hydrant system both inside the FFPH room and the yard with torque wrenches and use metal part protector on each nuts- bolts to avoid rusting. Replacement of damaged nuts-bolts if found any bolts should be stressed equally in opposite pairs during tightening the joints. | 2 | No. | 30,933 ₹61,866 Lowest | 32,500 ₹65,000 | 31,420 ₹62,840 |
| 1.09 | Trial test of the entire system by operating the deluge valve through emergency valve near deluge valve and through electrical actuation by operating solenoid valve from panel for four numbers of ICT's once in Two months, including flow test of the system. | 2 | No. | 32,450 ₹64,900 Lowest | 32,800 ₹65,600 | 32,590 ₹65,180 |
| 1.10 | Replacement of damage deep discharge battery 150AH 12Volt of 150KVA diseal engine of fire fighting system including cost of material copper termination cable with lug, labour and T&P. | 2 | No. | 47,950 ₹95,900 Lowest | 48,800 ₹97,600 | 48,210 ₹96,420 |
Tender Value
Refer Docs
EMD Value
₹35,500
Closing Date
13 Apr 2026, 5:00 pmClosed
P.K.Bhaskar
Superintending Engineer, OandM Circle, 400 KV Substation Campus, Kashipur -244713
Annual maintenance of fire fighting system at 400/220/132KV Sub-Station Kashipur
2026_PTC12_92992_1
SE(OandM)/PTCUL/KSP/48/2025-26
Open Tender
Electrical Works
Item Rate
365 days
Kashipur
3 documents required · 3 mandatory
₹1,180
EE, 400KV OANDM DIVISION KASHIPUR
₹35,500
2 May 2026
11 Mar 2026
14 Apr 2026
11 Mar 2026
13 Apr 2026
11 Mar 2026
11 Mar 2026 - 11 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Maintenance work of Hydrant/HVW pump of capacity 410 CU.M/hr at 70 MWC Head/1488 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | - | - |
| 1.02 | Maintenance work of Diesel engine driven stand by pump of capacity 410 CU.M/hr at 70 MWC Head/1500 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | - | - |
| 1.03 | Maintenance work of Jockey Pump of capacity 10.8 Cu.M/hr. at 80 MWC Head/2920 RPM work includes maintenance of impeller, shaft, shaft sleeve, coupling and gland packing replace, Use fibbers glands (Non Asbestos). Glands packing are internally lubricated, corrosion inhibitor free size and square packing. | 2 | No. | - | - |
| 1.04 | Maintenance work of sluice valve of inlet header and outlet header all size valves works include maintain packed with non asbestos fibbers gland. glands are internally lubricated, corrosion inhibiter prevent for spindle damage and maintenance for spindle and gland pusher ser on zero leakages. | 2 | No. | - | - |
| 1.05 | Cleaning of Hose boxes, panel, equipments, water storage tank once in a month. checking and rectifying hose, hydrant valves, pressure switch and solenoid valves, spray nozzle, deluge valve and push button piping throughout the switchyard for any leaks attending/ repairing. | 2 | No. | - | - |
| 1.06 | Maintenance of annunciation panel of hydrant system, checking and testing fire alarm detection system and rectifying the abnormal function of the system by repairing defective component, card of the system and defective smock detectors. | 2 | No. | - | - |
| 1.07 | Maintenance work of air vessel, diesel tank, A.c. distribution board, D.C. distribution board, battery charger, alarm system associated wiht fire fighting system as per site requirements. Testing all pumps D.G. set, panel, replacement of any faulty parts for proper operation of equipment also connection tightening all of all terminals. | 2 | No. | - | - |
| 1.08 | Tightening of all nuts-bolts of flangers, joints in the whole pipe line of the hydrant system both inside the FFPH room and the yard with torque wrenches and use metal part protector on each nuts- bolts to avoid rusting. Replacement of damaged nuts-bolts if found any bolts should be stressed equally in opposite pairs during tightening the joints. | 2 | No. | - | - |
| 1.09 | Trial test of the entire system by operating the deluge valve through emergency valve near deluge valve and through electrical actuation by operating solenoid valve from panel for four numbers of ICT's once in Two months, including flow test of the system. | 2 | No. | - | - |
| 1.1 | Replacement of damage deep discharge battery 150AH 12Volt of 150KVA diseal engine of fire fighting system including cost of material copper termination cable with lug, labour and T&P. | 2 | No. | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
PQR.xls
Tender Documents • 0.15 MB
format48.pdf
Other Document • 0.23 MB
BOQ_110069.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .