Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC MUKALATH VALAYANCHIRANGARA PO PERUMBAVOOR ERNAKULAM KOCHI 683556 | PERUMBAVOOR | ERNAKULAM | KERALA | 683556 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹12.5 L+₹24,597 (2.00%)Rejected-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹16.6 L+₹4.3 L (35.2%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical 0 AS ENTERPRISES DAYALACHACK HIRANAGAR KATHUA JAMMU KASHMIR 184144 | KATHUA | JAMMU AND KASHMIR | 184144 | - | Rejected-Technical Documents found not correct. | |
| 5 | Rejected-Technical | - | Rejected-Technical Documents found not correct. |
Tender Value
₹16 L
EMD Value
₹32,000
Closing Date
15 Oct 2024, 6:00 pmClosed
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
REPAIR/MAINT OF FIRE FIGHTING LT UG CABLES STREET LIGHT, DG SET, PUMPS, PANELS AND TRANSFORMER and CONNECTED WORKS AT NEDUMBASSAREY AREA UNDER AGE B/R ALWAYE
2024_MES_674954_1
CWE(NW)KOCHI/81462
Open Tender
Civil Works
Item Rate
330 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹500
GE(NS) Kochi
₹32,000
Yes
3 Dec 2024
17 Sept 2024
17 Oct 2024
17 Sept 2024
15 Oct 2024
1 Oct 2024
Amount
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, laying of pipes, cables, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out soft/loose soil.
Returning, filling in, including sreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
Supply and spreading locally available dry Riddle-Sand for covering and cushining of UG Cable in trenches complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm all as specified and directed
Supply laying and testingg XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm x 4 core complete all as specified and directed
Supply laying and testingg XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm x 3.5 core complete all as specified and directed.
M&L for servicing of HT VCBs, 400/630 Amp capacity indoor type by drawing out breaker assay from panel, cleaning/decarbonizing the contact points by suitable means, applying petrolium jelly, lubrication, adjust the trolly in and out mechanism and moving parts, testing of all tripping system and device, internal wiring circuit etc, tightning of all connections, replacement of HRC Fuse (if any found unserviceable) engage the VCB with the supply system and testing for smooth function complete all, as directed.
M&L for calibration of protective relays both 02 nos over current and 01 No earth fault relay of IDMT or any other type by using relay injection kit and re-set timing and tripping current according to the connected load complete all as directed.
Supply and filling of new transformer oil having di-electric strength not less than 45 KV complete all as directed.
Material and labour for filtration of insulating oil of transformer, voltage stabilizer’s etc in situation to bring the brake down value of oil not less than 40 KV at 2.5 mm gap all as specified and directed by Engineer-in-Charge including topping up of oil upto required level at different location.
Supply and replacing breather assembly of transformer with new silica gel suitable for any make of transformer of capacity 200 KVA complete as specified.
Comprehensive maintenance to APFC Panel indoor/outdoor including replacement of burnt out bakelite fuse of suitable size or capacitors of various sizes 5/10/20 KVAR and MCBs of any sizes as specified and directed. Note :- All accessories required to be replaced and will be measured and paid separately as supply only.
Supply only power capacitor (MPP) heavy duty in existing capacitor bank of capacity 5 KVAR as specified.
S & F in repair MCCB 415V 3 phase 50 HZ, 250 Amps 3 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting all as specified
S & F in repair MCCB 415V 3 phase 50 HZ, 125 Amps 4 pole of breaking capacity 25 KA with adjustable thermal magnetic release setting all as specified.
S&F LED street light fitting 60 Watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete inluding taking down old one.
Routine servicing, maintenance of DG Set 62.50 KVA, 6/4 cylinder/DG pump of any make to be carried out including supply & replacement of lubricating oil filter elemens, fuel filter elements, air cleaner element inner & outer with necessory 'O' ring, Engine oil, making good any leakages of oil, greasing the shaft fan motor, bearings and testing complete all as directed by Engr-in-Charge. Note :- Engine oil shall be measured and paid separately other parts are included in the quoted rates.
Removing the old engine oil fom the diesel engine sump of various DG Sets, cleaning the oil sump thoroughly, supply and fill new engine oil multigrade OMD-110/20W 40/SAE 40 in replacement of old engine oil all as specified and directed.
SSupply and fill coolent for radiator all as specified.
Replacement of water pump suitable for 62.50 KVA DG Set by removing/dismantling fan drive assembly, water hose connection and belt including replacement of fan hub bearing and shaft and testing the same after re-fixing complete all as specified and directed
Supply & fix in repair AVR unit suitable for 62.5 KVA DG set as per existing make and model all as specified.
M&L for overhauling and calibration of fuel injection pump (FIP) for 6/4 cylinder engine 1500 RPM including replacing injector nozzle, steel fuel pipe forFIP to injector, piston spring, worn outg nuts and bolts and washers gasket, re-fixing and testig on full load after completion for DG Set 62.50 KVA.
Supply & replace by pass flexible pipe suitable for 62.50 KVA Generator set.
Supply & replace fan belt suitable for 62.50 KVA capacities Generator set.
M&L for dismantling of self starter 12/24V from engine and transporting to workshop for repair, opening cleaning and replacing defective bushes, bendix pinion ball bearing, plunger assembly, solenoid switch, carbon brushes, brush spring including varnishing of coils heating, drying etc for DG Set 6.50 KVA complete all as specified.
Servicing of DG Panel, cleaning checking of electric connections, replacing defective components, meter, relays, indicating lamps and all other cotrol systems for the proper functioning of the panel of DG Set 62.50 KVA.
Supplying laying, jointing and testing Tubes, 'light grade' galvanised,with all fittings and fixed complete to walls or laid under road for passing cables complete of size 40mm all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Ditto as per item No 29 but using galvanised Earth plate of 600 x 600 x 6mm with iron strip 25×4mm as earthing lead.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling old one complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm including dismantling old one complete all as specified and directed.
S&F heat shirinkable jointing kit straight through joint suitable for LT indoor/outdoor cable end terminal joint (epoxy joints) any type suitable for aluminium conductor cable of size 10 sqmm to 95 sqmm 3.5/4 core complete all as specified and directed.
M&L for removing complete covers of the LT Panel board, Cleaning the bus bars with CTC solution, removing the carbon deposits, rust particles etc, tightning the bus bars, bolts, nuts including replacing with required new bolts, nuts, isulating the exposed portion with insulating tapes and replacing the damaged insulators/Hylem sheets etc and refixing the covers and testing complete all as specified and directed.
Supply & Fixing addressable manual call point resettable type complete.
Supply and laying of Fire Alarm Cable 2 core FRLS armoured copper cable of 1.5 sqmm complete all as specified and directed.
Supply, installation, Testing and commissioning of Detectors complying with and type certified to EN-45 addressable type multisensory detector with heat and smoke combination with base complete all as specified and directed.
Comprehensive maintenance of addressable fire alarm system installed at NAE functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed :- Make : Morely. (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Electronic siren - 02 Nos (d) Manual call points - 6 Nos. (e) Repeater Panels - 02 Nos. (f) 36 AH Battery - 02 Nos
M&L for cleaning inside RCC UG SUMP of 100000 Ltrs capacity (at NAE) by removing dirt, sediments, silts, algae etc from internal bottom and wall surfaces of tank using suitable brushes, applying bleaching powder and other cleaning agents as required including writing capacity of tank, date of cleaning and next due date of cleaning on outside the tank using the synthetic enamel paint All as specified and directed.
S&F cast iron body sluice valve heavy duty class PN 1.6 flanged ends any pattern with head wheels & brass spindle ISI marked confirming to IS-14846 of 2000 for 150 mm bore pipe with jointing material, flanged joints, rubber gaskets 6 mm thick, MS wedge nuts & bolts, washers 10 mm thick complete including dismantling old one all as directed.
Cutting of existing cast iron pipe line of upto 150mm bore in position for inserting CI/DI Special such as tees, bend, coller, tail piece etc for fixing of sluice valves/ for branch connection etc all as specified.
Supply and fixing upto 150mm dia bore DI/CI special such as bends, tees collars tail pieces confirming to IS-9523 flanged type complete all as specified and direcetd.
S&F CI foot valve of 150 mm dia confirming to IS 4038 complete fixed on suction pipe of pump all as directed
Supply and install fully star delta starter with single phase protection features in sheet steel enclosure type MN motor rating AC 415 Volts, 50 Hz, 3 phase of capacity 10 to 15 HP all as specified and directed.
Supplying, laying and testing ductile iron pipe flanged 150mm bore spigot class K-9 as per IS-8329 with inside cement lined complete with nut, bolts, packing etc all as specified and directed.
S&F, 500 litres capacity Rotational moulded polyethylene water storage tanks (ISI marked) (Cylindrica; vertica; with closed top) hoisted & fixed in position including taking down the unserviceable old one complete all as specified and as directed.
M&L for Non return valve 1.6 PN completed confirming to IS 1969 double falnged and drilled including bolts,nuts, washers, gaskets etc complete and dismantling of old one of size 150 mm dia completed all as directed by Engineer-in-Charge.
S&F Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard
S&F Hydrant valve single headed all as specified and directed.
S&F Hose reel drum 30m all as specified and directed.
Supply and fix outdoor type, weather proof cable junction box of size not less than 205 x 255 x 112mm, IP-65 suitable to terminate upto 25 sqmm 4 core and 2 core cables including dismantling old one complete all as spcified and directed.
M&L for HT/LT fault detector vehicle provide clear data and fault location all as specified and directedby Engineer in Charge
Supplying and laying synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 KV for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1 m
Same as item No 53 here in before but 2.5 mm thick for Voltage upto 11 KV (size 2x1 m)
Routine servicing, maintenance of Diesel engine centrifugal pump set 94 HP of any make to be carried out including supply & replacement of lubricating oil filter elements, fuel filter elements, air cleaner element inner & outer, Engine oil, making good any leakages of oil, greasing the shaft fan motor, bearings and testing complete all as directed by Engineer in Charge. Note :- Engine oil shall be measured and paid separately. Other parts are included in the quoted rates.
M&L for cleaning and preparation of old painted surface of CI/DI fire system pipe lines of dia 150/100 mm with synthetic enamelled paint one coat of existing colour all as specified
S&F Butterfly valve of size 150 mm dia all as specified and directed
S&F Butterfly valve of size 100 mm dia all as specified and directed
Supply, install test and commissioning of factory made outdoor type floor mounted LT cubicle panel board 415 volts, 3 phase 4 wire, 50 Hz AC supply, dust and vermin proof IP-54 Protection CPRI Approved having suitable size made out on 3.15 mm CRCA steel sheet powder coated as per IEC 61439 with aluminium bus bar of 300 Amps for phases and 200 Amps for Neutral duly laminated with colour coding sleeves. Mounted on MS angle iron frame of size 40x40x4 mm grouted in PCC type B2 above ground level including dismantling old existing panel board. The Panel board shall comprises with the following controls:- (A) INCOMING :- (a) MCCB 160 Amps, 4 pole, 415 Volts, 25 KA breaking capacity with adjustable thermal magnetic releae setting - 1 No (b) Digital type volt meter ( 0 to 500 Volts) 96 x 96 mm - 01 No (c) Digital type Ammeter ( 0 to 200 Amps) 96 x 96 mm - 01 (d) Indicator lamp (set of 3 ) - 01 set (B) OUTGOING :- (a) MCCB 40 Amps, 4 pole, 415 Volts, 25 KA breaking capacity with adjustable thermal magnetic release setting - 4 Nos (b) MCB SP, 32 amps, 220 Volts, 10 KA breaking capacity - 02 Nos Note : MCCB,MCB, Meters, Indicating lamps etc shall be included in the quoted rates
AR Traders (BID ID -3132934)
ELSOL ENGINEERS (BID ID -3131854)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .