| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.1 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹12.2 L+₹71,592.04 (6.24%)Rejected-AOC | 2 | Rejected-AOC OTHER THAN L1 BIDDER | |
| 3 | Rejected-Technical | - | Rejected-Technical NIT CRITERIA NOT FULFILLED |
Tender Value
Refer Docs
EMD Value
₹24,600
Closing Date
17 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender
2020_MES_364816_3
8644/2020-21/E8
Open Tender
Civil Works - Water Works
Item Rate
180 days
GE I P FY ISHAPORE
Class E Category a(ii)
6 documents required · 6 mandatory
₹500
GE I P FY ISHAPORE
₹24,600
Yes
19 Dec 2020
2 Nov 2020
19 Nov 2020
2 Nov 2020
17 Nov 2020
3 Nov 2020
2 Nov 2020 - 7 Nov 2020
60 days
Amount
SCHEDULE 'A' PART-I: EXTERNAL WATER SUPPLY
M & L for cleaning to over head tank capacity 50000 gallons with following methods. (i) Draining out the water from tank. (ii) Taking out the mud/sludge and deposits as directed by Engr-in-Charge. (iii) Cleaning and scraping out the inside surfaces with brush completely. (iv) Washing by the bleaching power and dewatering the same. (v) Lime washing to inner surfaces of the tanks. (vi) Rewriting the tank cleaned date and due date by synthetic enamel white paint on black painted surface all as directed by the Engr-in-charge.
M&L for cleaning of PVC/cement Tanks of capacity 2000 Ltrs with draining out of water, taking out Mud/sludge, washing & cleaning inner surface and rewritting the tanl cleaned date and due date all as directed by Engr-in-charge.
M&L for cleaning of PVC/cement Tanks of capacity 1000 Ltrs with draining out of water, taking out Mud/sludge, washing & cleaning inner surface and rewritting the tanl cleaned date and due date all as directed by Engr-in-charge.
Dismantling the submersible pump set 15HP at site including repair/replacement of spare parts as required and re-assembling the motor after repair including scrubbing old paint and painting with two coat of machine paint over a coat of red oxide primer all as directed by the Engr-in-charge. Note: Spare parts shall be measured and paid for separately as Suppy Only (a) Rewinding the motor with insulated copper wire as per existing gauge including dismantling burnt wire (b) Bushing of motor both side (c) Motor shaft stainless steel (d) Sand Guard for motor. (e) Thrust bearing for motor.
Supply only following spare parts for 15HP submersible motor:-
Rewinding the motor with insulated copper wire as per existing gauge including dismantling burnt wire
(a) Bush/Bearing of pump as per existing make and size
(b)Bush/ Bearing of motor as per existing make and size
(c) Thrust plate including connected items of the pumpset as per existing make and size
(d) Impeller of the pump as per exsisting make and size including connected items
(e) Gland packing of the pump as per exsisting size
Lowering of submersible pump 15HP capacity with column pipe 100mm dia into the deep tube well including rubber gasket,nut and bolts required for column pipe and making electric connection complete all as specified and directed.
Supply and fixing with jointing kit materials PVC insulated copper conductor 3 phase flat 10 sqmm 6core cable suitable for submersible pump complete all as directed.
Dismantling, cleaning and over hauling of 1/2 HP centrifugal mono block pump set/pressure booster pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing -02 Nos, including all connection and testing complete for following capacities :- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve.
All as per Iterm No 1.14 above but for pump set 3/5 HP complete all as specified and directed
Supply and fixing as in repair for 150mm bore CI Sluice valve PN – 1.0 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as specified having Body & Wedge Rings - Bronze IS : 318 Gr. LTB2. Spindle :- SS IS : 6603 Gr. 12Cr12. Gland Packing : Greasy Jute Packing. Flange Drilling - IS 1538, Table 4 & 6.
Taking up cast iron water mains with flanged/socket& spigot ends of 150mm size including all fittings complete
M&L for CI pipes of 150 mm bore with flanged ends, centrifugally cast, class A, in any length laid in trenches and column etc complete all as specified and directed
Supply and fixing of Bends (any type, radius and angle) tapers any type,(straight, bend, increasing,decreasing or double socket etc.) Tee pieces single branch. "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs for CI spigot and socketed pipes 150mm bore all as specified.
M&L for joint with rubber or fibre board gasket suitable for flanged pipes and fittings of 150mm bore including provision of bolts, nuts and washers complete all as specified and directed
Taking out steel water tubing and connections of 50mm dia bore including removal to schedule of credit
M/L GI Tubing 50mm bore medium grade of following size laid in trenches/fixed on wall, floor, ground including all accessories.
Supply and fixing as in repair for gun metal globe or gate valve class-1 (pressure rating) conforming to IS-778 with iron wheel head screwed both ends for GI tubing complete all as specified for 50mm bore of tubing.
Material and labour for replacement of DOL starter suitable for 1/2 HP capacity electric motor complete all as specified and directed.
Material and labour for replacement of DOL starter suitable for 3/5 HP capacity electric motor complete all as specified and directed.
Disconnecting and removing the unservicable (submersible pump) starter from the existing position and supply and fixing of new heavy duty , fully automatic star delta starter for submersible pump ,4 pole contactor type TC1DX ,overload relay type LR3D/LR1D,auto start switch, 3 position slector switch for SSPauto/SSP manual/manual, voltmeter,supersead scale ammeter,motor ON& TRIP LED indicator,TP "C" curve MCB for short cicuit protection, relay range 14-23 Amps for 15 HP motor ,complete all as specified and directed
M& L for run lead joint for spigot and socket of 150 mm bore pipes and fittings complete all as specified and directed.
M&L Construction of brick masonry valve pit of size 600 x 600 x 750mm (internal dimension) with one brick thick P.C.C 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in foundation concrete incl PCC (1:3:6) type C1 (using 20mm graded crushed stone aggregate) as in bedding and coping 10mm thick cement plaster in Cement mortar (1:4) internally & externally upto 15 cm below ground level providing valve pit 40x40x6mm angle iron frame all round the fixed point by means of 4 Nos hold fast 150mm long made out of flat iron 40 x 6 mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) of size 230 x200 x100mm. incl provn of hing welded with angle iron frame and Mild Steel cover 3.15mm thick, Mild steel handle of suitable and size welded with Mild Steel cover & suitable locking arrangement & applying two coats of synthetic enamel paint over a coat of red-oxide primer incl necessary excavation work in soft/ loose soil complete all as specified & directed
SCHEDULE 'A' PART-II:EXTERNAL ELECTRIFICATION
Taking out Existing UNSV LT cable of size 35 sqmm to 50 sqmm any position complete from trenches, wall & making the good the disturbed surfaces all as specified and directed.
All as per item no 2.01 above but LT cable of size 16 sqmm to 25 sqmm.
All as per item no 2.01 above but LT cable of size 06 sqmm to 10 sqmm.
M & L as in repair for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of following sizes all as specified and as directed for the following:-
50 Sqmm 3.5 core
16 Sqmm 4 core
10 Sqmm 2 core
Taking down of unserviceable Security light fittings 70/150 watts including GI bracket from LT steel tubular/PCC pole /building(8.5m long/9 mtr long)
M&L for PVC unsheathed copper cable 1.5 sqmm multistranded copper conductor for connection of street light Note passing into the pole and connection including necessary protection work including taking down unserviceable one. Note:-Two run of 1.5 Sqmm wire shall be measured as a one unit.
Supply & fixing as in repair for LED Street light 45W made of pressure die cast housing with toughened glass and high power Led's with option of secondary optic with IP65 protection complete all as specified. Make Crompton Cat No LSTS-45-CDL-M or equivalent as in the list of makes.
Taking down old damage junction box and supply and fixing new junction box PVC of size 250 mm x 250 mmx 160 mm with hinged type door 4 Nos terminal 15 Amps for fixing on pole with necessary fixing arrangement such as jointing material, nuts, bolts, washers and clamps etc complete all as specified and directed.
S&F in repair for street light bracket made out of 32mm dia GI light grade tubing not less than 1.5 mtr long bend to shape including pole clamps made out of 40 x 6 FI and nut, bolts and washers and painting with two coats of Aluminium paint over a coat of red oxide primer complete all as specified.
M & L for painting steel tubular swaged poles 9m long and exc 10cm in width or girth after removing old paint from external surface of poles including pole fittings such as cross arms of any description, anti-climbing devices, nut, bolts etc. by hand scrapping and rubbing down with sand paper and applying two coats of aluminium paint and numbering of poles with white paint on black paint base and stripping with black paint (100 mm each stripe) 3 Nos at equal distance from bottom (above PCC coping) upto a height of 1200 mm complete.
'-----Blank----------
Earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip 32 x 6mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (light grade) and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I complete including testing on completion all as specified.
M & L spray painting including throughly rubbing and cleaning with sand paper inside and outside of existing LT panel boards outdoor type of size not exceeding 2m x 2.5m x 0.75m in depth with two coats of synthetic enamel paint over a coat of anti rust primer of superior quality and approved colour after preparation of steel surface all as specified.
Disconnecting HT/LT side electrical connection carefully existing 11/6 KV/440 Volt step down transformer any capacity, draining out and refilling of existing transformer oil after filteration dehydration and measuring the dielectric strength which should not less than 30 KV including change of silica gel, gaskets and reinstallation of transformer satisfactory on its original position, connecting testing and commissioning complete all as specified and as directed. Note: Transformer oil shall be measured and paid separately as supply only.
Supply of transformer oil confirming to IS-335 Make Gulf/IOC/Servo for topping up to oil level of transformer.
Cable Jointing Kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type complete with jointing material and accessries suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmmcomplete all as specified and directed.
Excavation in trenches n.exc 1.5 M wide and not exc. 1.5 M in depth for foundation etc or for shafts, wells, cesspits, manholes, pierholes, etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil.
Excavation in trenches n.exc 1.5 M wide and exc. 1.5 M in depth for foundation etc or for shafts, wells, cesspits, manholes, pierholes, etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil.
Removing of excavated material not exceding 50m and deposited where directed at a level not exc 1.5 mtr above the starting point in soft/loose soil all as specified and as directed.
Returning filling in ,including spreding, levelling, watering and well ramming in layers n.exc 25 cm all as in soft/loose soil all as specified .
M&L for sand cushioning of under ground cable with coarse sand laid dry by filling in trenches with approved coarse sand with uniform thickness, complete all as specified and directed.
Supply and laying old size common burnt clay sub class 'B' bricks for protection of UG cables.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregates) as in foundation filling and mass concrete of poles complete all as specified and as directed.
Materials and labour for PCC (1:2:4) type B-2 (using 20mm graded stone aggregate) as in coping including necessary form work and concrete exposed surfaces finished even and smooth using extra cement complete all as specified and as directed.
Materials and labour for PCC (1:4:8) type D2 (using 40mm graded stone aggregate) as in Base foundation of pole including necessary form work and concrete exposed surfaces finished even and smooth using extra cement complete all as specified and as directed.
Supply and fixing galvanised steel tubing 50 mm bore, light grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) and laid in floors or fixed on walls for earthing strip protection complete all as specified and as directed.
M&L for Aluminium lugs for 120/95 Sqmm cable complete all asspecified and directed.
Site clearance by cutting and removing small grasses/bushes and surface dressing n exc 15cm deep complete all as specified and directed.
Dismantling old U/S GOD from poles and M&L new air break , gang opereated device ( GOD )for TP ,mechanically oprated ,mounted on insulator and steel frame with operating mechanism worked from grond level ,for current ratinng 200 Amps for 11000 Volts grade complete all as specified and directed.
Dismentling Old unserviceable light fittings and S&F decorative type LED Post top lantern fitting for 360° indirect light and resistant to impact and corrosion, glare free and better uniformity ,IP65 protection of 40 wattage along with pipe and fitting accessories including elctric conection wires, complete all as specified and directed Make: Crompton LPTOI-45-CDL , Bajaj, BRIL 45W LED NW or equivalent in other Make of Havells/Philips
Maintenance of HT Vacuum Circuit Breaker, 7.2 KV, 400 Amps, Make- Crompton Greeves for trouble free operation, opening the incoming / out going HT cables carefully after disconnecting the HT supply, cleaning all terminals, fixed / moving contacts, cleaning vacuum interrupter, insulating coupler, strut, centering ring, all terminal clamp and bolts, drive link, upper/lower post insulators, etc. Special care need to be exercised in removal or insulation of hardware around the bottom, movable contact end of the vacuum interrupter, etc and refixing all HT cable terminals, cover, etc including the following inspection and checking should be carried out complete all as specified and directed including the following: -
(a) Primary power path check (i) Cleanliness check (ii) Inspection of flexible connections b) Stored energy operator-mechanism checks (i) Maintenance and lubrication (ii) Fastner Check (iii) Manual spring charging check (c) Electric Control Checks (i) Wiring and control check (ii) Secondary disconnect check (iii) Automatic spring charging check (iv) Electrical close and trip check (d) Vacuum Integrity check (e) High potential check (f) Insulation test (g) Contact resistance test (h) Inspection and cleaning of circuit breaker insulation (j) All safety and relay functional tests to be carry out followed by with submission of rest report to the engr-in-charge
Note : - (i) Any cleaning compounds containing chlorinated hydrocarbons, such as trichlorethylene, perchlorethylene or carbon tetrachloride will not be allowed to use which may damage the phenylene ether copolymer material used in the barriers and other insulation on the circuit breaker. (ii) Contractor will ensure to provide recommended tools for the maintenance works of the VCB. (iii) Contractor will ensure and take all safety precautions / preventive measures against the mechanic / electrician at his own risk. (iv) The contractor will provide authorised representative of OEM to execute the work. (v) Struts, lower connection pad, contact pressure spring, insulating coupler, guide link, Eye bolt ,other spares, etc to be measured and paid separately.
Supply only against item No. 2.36 here-in-before as per existing make and size :- (a) Strut (b) Upper Connection pad-Each-01 No (c) Lower connection pad-Each-01 No (d) Contact pressure spring-Each-01 No (e) Insulating coupler-Each-01 No (f) Guide link-Each-01 No (g) Eye bolt-Each-01 No
Disconnecting electric supply from the 6 KV 400 Amp OCB make Alstom, Opening of the OCB complete repairs, Overhauling of the OCB supply and replacing of fixed contacts - 03 Nos, moving contact-3, insulating bushes-6 Nos, gaskets washers, nuts bolts refixing and reconnecting back including charging with new transformer oil die electric strength not less than 30 KV of required complete all as specified and as directed.
RUNJEN CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .