Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC HOUSE NO 599 D SURYA NAGAR PHASE II SECTOR 91 FARIDABAD 121013 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121013 | L1 | Accepted-AOC AOC | |
| 2 | L2₹24.2 L+₹6.3 L (35.3%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L2 | Rejected-Finance Rejected being | |
| 3 | L3₹25.6 L+₹7.7 L (43.1%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-Finance Rejected being |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
25 Jul 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)/AMB-19(P)/2020-21 DAY TO DAY MAINTENANCE OF E AND M COMPLAINTS, FITTINGS, FIXTURES AND OTHER MISC WORKS IN OTM ACCN IN AREA-II SECTOR A OF AGE E AND M (N) UNDER GE (N) AMBALA CANTT
2020_MES_338804_2
GE(N)Amb-19(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Document
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹70,000
Yes
17 Aug 2020
26 Jun 2020
27 Jul 2020
26 Jun 2020
25 Jul 2020
11 Jul 2020
27 Jun 2020 - 10 Jul 2020
60 days
Amount
Supply & Fix switch piano, flush type single pole, one way 5 Amp including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply & Fix bell push 6 Amp including removing unserviceable items including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply & Fix socket 2/3 pin 6 Amp including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply & Fix switch piano flush type single pole, one way 15 A including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply & Fix socket 6 pin 5/15 Amp multi purpose 230V including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply & Fix Step fan regulator electronic socket type, flush type 230 volt including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply & Fix Step fan regulator electronic switch type, flush type 230 volt including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply & Fix in replacement of capacitor 2.5 mfd for ceiling fans of any descriptions including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply & Fix calling bell ding dong 230 V including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply & Fix mild sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-1) of 1969 of size 7"x4" including fixing arrangement with necessary cement work and removing unserviceable items.
Supply & Fix mild sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-1) of 1969 of size 8"x10" including fixing arrangement with necessary cement work removing unserviceable items.
Supply & laying 1.5 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volt grade ISI marked with multi stranded copper conductor through existing conduit/ casing & caping complete all as specified and directed including taking out of old unserviceable/burnt out wire of any size,connections all as specified and as directed by Engr-in-charge. Note: Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB
Ditto as per item No 1.12 here in before but 2.5 sqmm,connections all as specified and as directed by Engr-in-charge.
Ditto as per item No 1.12 here in before but 4.0 sqmm, connections all as specified and as directed by Engr-in-charge.
M&L for rectifying the short circuit of internal wiring/ sub main wiring replacing the burnt wire with the rating of existing wire as required at site. Note:- 1. The complaint will be attended round the clock and the contractor will be penalized @ Rs 150 per hour when the complaint will not be attended within 2 hrs of issuing of the complaint. 2. Other details as per particular specifications and the rates quoted may be deemed to include the same.
M&L for rectifying the current leakage /electric shock of internal wiring/ sub main wiring ensuring that no leakage current passes Note:- 1. The complaint will be attended round the clock and the contractor will be penalized @ Rs 150 per hour when the complaint will not be attended within 2 hrs of issuing of the complaint. 2. Other details as per particular specifications and the rates quoted may be deemed to include the same.
Supply and fix ceiling rose surface type 2/3 terminal 5 amps complete including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply and fix lamp holder, insulated body, with back plate for angular batten fittings complete all including taking down unserviceable item, connections all as specified and as directed by Engr-in-charge.
S&F LED lamp 9 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete including taking down unserviceable bulbs all as specified and as directed..
S&F LED lamp 12 watt threaded/pin end, warm/cool lamp type as per site requirement suitable for fixing on existing batten/angular holders complete all including taking down unserviceable bulbs as specified and as directed.
Supply and fixing LED batten fitting 18-20 watt, 4 feet "aluminium body including driver & tube rod" /warm white industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down unserviceable light fitting of any type and capacity and removal connections all as specified and as directed by Engr-in-charge.
Supplying and fixing in replacement LED tube rod 18/20 watt 4 feet, aluminium body, cool/warm white industrial model with high frequency power factor suitable for surface mounting batten fitting complete including disconnecting and taking down U/S tube rod of any type all as specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement recess mounting LED 15/18 Watt circular down lighter/ COB panel with aluminium die cast housing, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with 3 core flexible copper conductor from ceiling rose to connector of the light, including disconnecting and taking down existing old U/S fitting complete all as specified and as directed.
Supply and fix MCB SP 6-32 Amps, 240 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Supply and fix MCB SPN 32/40 Amps, 240 volt,10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
Supply and fix MCB TPN 63 Amps 240 volt, 10 KA 'C' curve including removing old Unserviceable MCB complete all as specified and directed.
S&F MCCB 3 pole , 63 Amp, 415 Volts 16 KA ,fixed type including fixing arrangement, including removing old Unserviceable MCCB complete all as specified
S&F MCCB 4 pole , 100 Amp, 415 Volts 25 KA ,fixed type including fixing arrangement, including removing old Unserviceable MCCB complete all as specified
S&F MCCB 4 pole , 200 Amp, 415 Volts 35 KA ,fixed type includingincluding fixing arrangement, including removing old Unserviceable MCCB complete all as specified
Supply and fix RCBO 32 Amps 2 Pole 100 ma (HI immunity) sensitivity 230 volts 50 Hz ISI marked, including removing old Unserviceable RCBO complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp including removing old Unserviceable enclosure complete all as specified and directed
Supply and fixing LED flat panel 2' x 2' size surface/ recess mounted fitting (grid/ gypsum type) 36-40 watt industrial model, warm/cool white with provision of PVC flexible copper conductor cable to light fitting, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and directed.
S & F LED Bollard 8-10 W, IP-65 luminaire made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply , complete with all accessories internally pre wired including connecting with flexible copper conductor from Electric Supply Source to connector of the light including PCC 1:3::6 of size 400x400x400 mm, including disconnecting and taking down existing old U/S fitting and removing complete all as specified and as directed.
Supply & Laying PVC insulated and PVC round sheathed, Copper conductor(flexible) industrial cable 3 core 2.5 sqmm 1100 volts confirming to IS: 694 cable including taking down old U/S cable complete all as specified and as directed..
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed 6 sq mm in service connection, including disconnecting and taking down old U/S existing cable complete all as specified and as directed.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty 2 core cable with PVC insulated aluminium conductor multistranded served with an inner sheathing of PVC tape and overall PVC sheathed 10 sq mm in service connection, including disconnecting and taking down old unserviceable existing cable complete all as specified and as directed.
S & F LED post top luminaire 30W IP-65 made of pressure die-cast aluminium housing & clear glass 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with fitting and including fitting & provision of 3 core PVC flexible copper conductor from Electric Supply Source to connector of the light, including disconnecting and taking down existing light fitting and removing old unserviceable fitting complete all as specified and as directed.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 0.9 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site and making electrical connection, including disconnecting and taking down existing old U/S fitting complete all as specified and directed.
Taking down ceiling/exhaust/wall mounted/pedestal fans of any sweep of any make with down rods, blades canopy etc by disconnecting the electric connections and deposit at fan store of AGE EM north for issuing of fan to contractor for repair, and collecting the fan after repair hanging the same at location directed by the concerned JE EM all as specified and as directed
M&L for opening the stator & rotor of the 1200mm sweep ceiling fan cutting the existing worn winding & rewinding the fan with superior quality rewinding wire & filling the varnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing serviceable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes, ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing, oiling & testing of fans all as per manufacturers design & speed complete all as directed & approved for 1200mm sweep. Notes for item NO (i) to (vii) :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out serviceable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No on fans (v). Unserviceable /defective retrieved parts shall be credited vide sch of credit. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans shall be repaired/rewind at AGE E/M store yard only.
All as per srl item No 1.40 here-in-before but for 1400 mm sweep, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.40 here-in-before but for air circulation fans, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.40 here-in-before but for Exhaust fans of 225/250mm sweep, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.40 here-in-before but for Exhaust fans of 300mm sweep, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.40 here-in-before but for Exhaust fans of 450mm sweep,connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.40 here-in-before but for wall cabin fans of 400mm sweep, connections all as specified and as directed by Engr-in-charge.
supply only GI 'U' clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete including removing unserviceable items.
Supply only PVC canopy cover superior quality all as specified and as directed including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply only down rod 60cm long made out of 15 mm bore light grade GI pipe having provision of fixing U clamp & Fan including painting the pipe with superior quality white colour synthetic enamel paint all as specified including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.49 here-in-before but 1m long,connections all as specified and as directed by Engr-in-charge.
Supply and fixing LED batten fitting 10-12 watt, 2 feet, aluminium body including driver & tube rod industrial model complete connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
Supply and fixing LED surface mounted bulk head luminaries 8-10 W with min 800 lumen ,industrial model, IP 65, Aluminum housing, surge protection including drivers etc complete with all accessories connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and directed.
M&L for cleaning the fan motor assembly body, blade of ceiling fan, filling the cavity rubbing with sand paper, taking off old paint with the help of chemicals & painting the ceiling fan/Exhaust fan with one coat of superior quality synthetic enamel paint including writing the MES number on the ceiling fans of 1200mm sweep with black colour synthetic enamel paint all as specified and as directed.
All as per srl item No 1.53 here-in-before but for 1400 mm sweep,connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.53 here-in-before but for Exhaust fans of 225/250mm sweep, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.53 here-in-before but for Exhaust fans of 300mm sweep, connections all as specified and as directed by Engr-in-charge.
All as per srl item No 1.53 here-in-before but for Exhaust fans of 450mm sweep,connections all as specified and as directed by Engr-in-charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply only bearing No 6203 for 1200/1400mm sweep ceiling fans including removing unserviceable items,connections all as specified and as directed by Engr-in-charge.
Supply only capacitor 4 MFD dry type including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply only fan blade suitable for 1200 mm sweep fan of existing make including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply only fan blade suitable for 1400mm sweep fan of existing make including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
Supply & Fixing LED Flood lights, 120 watt IP-65, 240 volt, 50HZ, AC supply complete with all accessories internally pre wired including connecting with flexible copper conductor to connector of the light with necessary fixing arrangements, including disconnecting and taking down existing old unserviceable fitting complete all as specified and as directed.
S & F LED high bay/medium bay luminaire 80-90 W,IP-65, indoor type input voltage range 120-270 volts with provision of 3 core copper conductor cable 1.5 sqmm size from connector/ceiling rose to fitting with fixing arrangement as per site requirement/conditions and including removing old unserviceable fitting complete all as specified and directed..
M&L for arresting the leakage of the geyser by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by Engr-in-charge. Note : Adequate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank is still leaking the same will be repaired by the contractor the cost to be deemed to be included in the quoted rate.
Supply & replacing heating element of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating element,connections all as specified and as directed by Engr-in-charge.
Supply & replacing heating element ISI mark cup or triangle type of 1.5/2 KW as required at site for geyser of any make and any descriptions including taking out old unserviceable heating elements all as specified and as directed by the Engr-in-charge.
Supply & replacing thermostat switch for geyser of any type ISI marked including taking out old unserviceable thermostat switch all as specified and as directed .
Supply & replacing geyser inner tank assembly suitable for geyser capacity of 25 Ltr including taking out old unserviceable tank assembly all as specified and directed.
Ditto as per item No 1.71 here in before but 50 ltr capacity,connections all as specified and as directed by Engr-in-charge.
Supply & replacing inner tank for geyser of 25 Ltr capacity including taking out old unserviceable inner tank all as specified and as directed by Engr-in charge.
S&F Chromium Plated non return valve 15mm bore with air lock relapse arrangement ISI marked including taking out old unserviceable non return valve,connections all as specified and as directed by Engr-in-charge.
Supply & replacing metal clad socket top as per existing socket including taking out old unserviceable metal clad top connections all as specified and as directed by Engr-in-charge.
Supply & replacing of inspection cover stainless steel in 2 piece suitable for geyser of 50/25 ltr capacity and having provision of fixing indicator lamps including taking out old unserviceable inspection covers all as specified and as directed by Engr-in-charge.
S & F in replacement PVC insulated 3 core circular stranded copper conductor of 1.5 sqmm including removing unserviceable itemsconnections all as specified and as directed by Engr-in-charge.
S & F in replacement PVC insulated 3 core circular stranded copper conductor of 1 sqmm including removing unserviceable itemsconnections all as specified and as directed by Engr-in-charge.
S&F Chromium plated gate valve of 15 mm bore suitable for fixing on existing fittings including taking out old unserviceable gate valves all as specified and as directed by Engr-in-charge.
S&F brass connection pipe having wire mesh coating over it with PTMT nuts and washers suitable for connecting geysers inlet and outlet with GI tubings including taking out old unserviceable brass connections all as specified and as directed by Engr-in-charge.
S&F GI tubing 20mm med grade with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site including removing unserviceableitems all as specified and as directed by Engr-in-charge. Note: rate quoted will deemed to include the plumber work as per site requirements.
S&F plug top 15 Amp 3 pin including taking out old unserviceable plug top including removing unserviceable items, connections all as specified and as directed by Engr-in-charge.
S&F indicating lamp green/red in colour 230 volts as per existing make including removing unserviceable items.
S & F key guard switch, 1 way, DP with LED lamp, 2 module,voltage range from 110-250 volts AC, 16 Amps capacity, colour as specified by the user including fixing arrangements with sunken box of suitable size complete testing and commissioning complete all as specified and as directed by Engr-in-charge.
S&F Automatic 1HP pressure Pump with Pressure control switch with fully automatic water level controller including removing unserviceable items all as specified and as directed by the Engineer-in-Charge.
Contractor or his rep (Tradesman) will report at service center daily at 0845 hrs, will receive the complaints lodged by user and attend/complete the complaints, will give feed back about the complaints to JE/AGE daily at 1700 hrs. The complaints which are not attended by the contractor on same day will be penalized @ Rs 150.00 per day except for items Ser Nos 1.01 & 1.02. Complaints will be Signed by user/user rep or in absence, by concerned JE. Final decision in case of dispute whether the complaint has been rectified or not will be of concerned JE/Engr-in-Charge.
M & L attending day to day internal electric complaints received via Armaan, off line, Maintenance Mela or through other means & electric audit for preventive electric maintenance by electric alongwith the helper with required tools, transportation & safety devices on all working day from 0900 hrs to 1700 hrs (or in emergency in non- working hours & around the clock) . Any complaint requiring replacement of item will be paid in S & F under respective items of CA.
Site/ complaints will be given on daily basis & not at a glance as the contract pertains to day to maintenance of E & M services.
Contractor has to bring supply & fix items of the CA at E & M service center in quantum as mentioned by Engr-In-Charge. The same will be issued on daily basis to tradesmen employed by contractor against complaints registered by users.
Contractor will hand over the dockets & UNSV item at service centre daily at 1700 hrs or within 24 hrs.
The UNSV item as per schedule of credit will be handed over to the contractor after payment only.
Progress of work will be measured on daily basis on restoration of complaints/jobs.
Contractor has to submit the following details of tradesmen employed by him:- (a) Police verification (b) Qualification certificates (c) Aaadhar Card
For LED luminaires the following measures will be observed:- (a) Local representative of the company will certify the compliance of the specification of the luminaire and genuineness at site. The rep will also certify the genuineness of PVs. (b) Contractor shall also submit the third party LM-79 & LM-80 report of the fittings from certified labs. (c) Two year warranty certificate not signed below the rank of regional manager to be submitted by the contractor.
Payment will not be progressed without submitted the above mentioned documents & PVs
The rates quoted shall be deemed to include provisions of above points.
R N Enterprises
Saurav Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .