Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹36.5 L+₹2.3 L (6.63%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹38.8 L+₹4.5 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹38.9 L+₹4.6 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹43.9 L+₹9.6 L (28.1%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹34.3 L
EMD Value
₹68,600
Closing Date
4 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Barrackpore
Office of the Garrison Engineer Barrackpore , Kolkata-700120
SPL REPAIR TO OVER HEAD RESERVOIR AND REPAIR TO STAIR CASES AND CHAJJA TO CERTAIN OFFRS ACCN AND PROVISION OF 2X TOILET AND BATHROOMS AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_486708_1
8583/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹68,600
Yes
24 Dec 2021
6 Nov 2021
6 Dec 2021
6 Nov 2021
4 Dec 2021
22 Nov 2021
60 days
Amount
Demolition of cement concrete (un-reinforced) as in roofs, floors (other than ground floors), beams, stair cases, landing, chajjas and similar suspended work for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in roof kerbs on roof top of overhead reservoir tank or mud stops rounded or chamfered on edges including necessary form work finishing the surface even and smooth without using extra cement for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in top of chajjas, coping, bed plates, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and smooth without using extra cement for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1 (using 20mm graded crushed stone aggregate) as in beams, roof beams, bases for column etc and mass concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1(using 20mm graded crushed stone aggregate) used as in walls, retaining walls, basement walls, ballast wall and the like, any thickness above top of footings including attached pilasters and buttresses for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for form work to sides of base of column, side and soffit of beam and similar work for flat, rough finish surface of concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter finished rough surfaces of concrete for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
S&F for mild steel work in tubular trusses and purlins including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 after and including dismantling of existing unserviceable truss for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for rolled mild steel in stair (framed) including stringers, treades, landing, balusters, hand rails etc including cleats, brackets etc (Fe-410W, Gde-E-250) quality A after and including dismantling of existing unserviceable stair for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
S&F for expanded metal, weight per sqm exceeding 4 Kg, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples complete to wood or steel members for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
S&F for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm but not exceeding 15 cm long with dia meter of neck 11 to 15mm dia for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
M&L for 25mm (avg) thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in roof padding mixed with WPC as per manufacturer's instructions finished the surface even and smooth without using extra cement for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed. (Note : WPC shall be measured and paid separately).
M&L for rendering 15mm thick on concrete surfaces of walls with cement mortar (1:4) mixed with WPC as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement and applying two coats of cement based paint over a coat of alkaline resistant primer after and including taking down existing cement plaster of any description including racking out joints hacking for key, scrubbing down with water etc for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15 mm thick on concrete surfaces of walls with cement mortar (1:4) mixed with WPC as per manufacturer's instructions , finished the surfaces even & smooth without using extra cement and applying three coats of white wash after and including taking down existing cement plaster of any description including racking out joints hacking for key, scrubbing down with water etc for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15mm thick in cement mortar (1:3) on fair faces of brick work or concrete with GI wire netting of 0.9 mm dia and 12 mm mesh lathing to wood or metal studding, joist etc in walls, ceiling stanchions, beams etc including all laps, cutting and waste in patches mixed with WPC as per manufacturer's instructions, finished the surfaces even & smooth without using extra cement and applying three coats of white wash after and including taking down existing cement plaster of any description including racking out joints hacking for key, scrubbing down with water etc for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for shortcrete to existing RCC members after removing all loose concrete and preparations of surface, application of de-rusting chemical such as Dr. Fixit rust remover or equivalent and applying anti rusting solution to exposed surfaces of existing steel, welding steel wire febric or reinforcement as required if , priming reinforcement bars with a coat of zink primer of coating not less than 40 micron, applying of bonding agent of Dr. Fixit bonding agent or equivalent and repair to external RCC structure with slurry tight and strong form work and shortcreat of mix (1:3:1) ( one part cement three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thickness and applying 10mm thick cement plaster in cement mortar (1:3) and finished the surface even and smooth and applying two coats cement based paint over a coat alkaline resistant primer, including necessary scaffolding as required at site for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed. (Make of rust remover, anti rusting solution, bonding agent :- Dr Fixit /Fosroc / Sika as approved.) (Note : Reinforcement will be measured and paid separately)
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth for height 18mtr to 20 mtr RCC overhead reservoir complete all as specified and directed.
Taking out of existing un-serviceable tarfelt / bituminous membrane on roof and parapet of any roof height carefully by cutting chiseling or by any mechanical way, cleaning the surface by scraping, brooming, brushing etc and removing the rubbish from site complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) as in roofs, floors (other than ground floor), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for approved earth filling, earth obtained from out side of Defence land to a distance exceeding 1.5 Km upto total distance 5 Km and depositing where directed and spreading and levelling in layers not exceeding 25 cm thick complete all as specified and directed.
Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified and directed
Excavating over areas, not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavating over areas, exceeding 1.5 m but not exceeding 3.00 m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation or for shafts, well, cesspits, pier holes, laying of drain pipes, pipe line, cable and getting out in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm, soil complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:5:10) type E-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) as in copping, bed plates, kerbs etc including weathering, slightly rounded or champhered angel and throating including necessary form work complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in copping of manholes / drains, benching and channel of manhole / drains, and also for bed blocks for embeddings MS rungs of manhole / septic tank including necessary form work complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in foundations including rafts, footings, foundation beam, plinth beams, bases for columns etc , basement slabs, under-reamed piles and mass concrete etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in column, pillar, piers, post and struts etc complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in slab supported on walls, beams and columns in floors, roofs, landing, balconies, canopies, deck slabs and in shelves and like etc complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab/slab of drain/manhole water tank/shelf, landing, cooking platform set in cement mortar (1:4) complete all as specified and directed. (NOTE: Cost of Form Work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M&L for RCC (nominal mix) (1:1.5:3) type B1 (using 20mm graded crushed stone aggregates) as in chajjas complete all as specified and directed.
M&L for RCC (nominal mix) (1:1.5:3) type B1(using 20mm graded crushed stone aggregate) used as in steps (square or spendrill) string pieces, carriage etc complete any section straight or winding complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for form work to sides of concrete foundation, footing, base of column, raft & plinth beam for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc also splays between floors and beams etc for flat, rough finish surface of concrete complete all as specified and directed.
M&L for form work to sides of pillar, posts, struts, piers, columns and stanchions for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to chullah hoods, chajjas, troughs and similar items including edges for flat, rough finish surface of concrete complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs exceeding 5 cm but not exceeding 10 cm wide for rough finished surfaces of concrete, flat complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for formwork to stair cases with sloping or stepped soffits including riser and stringers finished surfaces of concrete complete all as specified and directed
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for 300 mm aluminum alloy, anodised, sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for steel ventilators with top hung shutters including hinges, steel peg stay complete all as specified and directed
S&F for steel windows with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wiremesh including one coat of red oxide zinc chrome primer at factory complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate), as in sub base to footpath, floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 25mm thick cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floor finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of plastered surfaces 1.5mm thick and applying polymer modified bituminous elastomeric water proof coating as per manufacturer's instructions for sunken portion of toilet, bathroom and similar portions at any place/location and in any condition all as specified and directed by Engineer-in-Charge (Make : PIDILITE INDUSTRIES LTD (Dr FIXIT proof coat) or equivalent of IWL/TEXSA /STP as approved). The work should have be carried out by Authorised Applicator of Manufacturer's as approved by GE. (NOTE: The rate includes for preparation of surfaces treatment and sealing of all joints, cracks, corner and junction of pipes etc. and ponding test complete all as directed by Engr-in-Charge)
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or beading layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 300 mmX7 mm thick or equivalent set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for 20mm thick screed bed in cement mortar (1:4) on RCC roof surfaces for laying of APP membrane mixed with WPC as per manufacturer's instructions complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with cement mortar (1:4) mixing with WPC as per manufacturer's instructions, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for applying three coats of white wash on surface of ceiling including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer on ceiling surfaces after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer on wall surfaces after preparation of newly plastered surfaces complete all as specified and directed.
M&L for applying two coats of cement based paint over a coat of alkali resistance primer on newly plastered surface of walls including preparation of surface complete all as specified and directed.
M&L for preparing surfaces of steel and iron work, new or old treating small articles such as stop, covers, gully gratings, holdfasts, ends of posts, backs of chowkats, etc., area not exceeding 0.1 sq. m each and treated with tar or coal tar black paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane complete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F for 15 mm bore stop valve, fancy type chromium plated , cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 20 mm bore stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 25 mm bore stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed as in repair complete all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed complete all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges complete all as specified and directed.
S&F for chromium plated health faucet with 15mm dia CP tube of 1.2 mtr long complete all as specified and directed.
S&F for 125mm dia grating with waste hole , fancy type, chromium plated complete all as specified and directed.
S&F for brass chromium plated toilet paper holder fixed to walls with chromium plated brass screw complete all as specified and directed.
S&F for 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed complete all as specified and directed.
S&F for 15 mm dia PVC connection pipe of length 450 mm with PTMT nuts complete all as specified and directed.
S&F for urinal spreader of PTMT any colour for fixing with 15 mm dia pipe. (Minimum weight 60gms) complete all as specified and directed.
S&F for 25mm dia ball brass valves, high pressure, with polyethylene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 25mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 25mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 20 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 25 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer, (three layer) ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm ball valve high pressure of PTMT complete all as specified in SSR Part-I and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm ball valve high pressure of PTMT after and including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F for 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection with and including 25mm ball valve high pressure of PTMT after and including dismantling / taking down old PVC water tank, ball valve etc all as specified in SSR Part-I complete all as specified and directed.
Disconnecting existing water tanks of (exceeding 500 & not exceeding 1000 litres in capacity), setting aside (or lowering if required) and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in position with required fittings complete all as specified and directed. (NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank)
Disconnecting existing water tanks of (exceeding 250 & not exceeding 500 litres in capacity), setting aside (or lowering if required) and cleaning, removing all scale and dirt etc from tanks and mouth of pipe including hoisting (if required) reconnecting and refixing in position with required fittings complete all as specified and directed. (NOTE: Date of cleaning must be written at side of water tank with white paints after cleaning of tank)
S&F for vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement complete all as specified and directed.
S&F for vitreous china wash basin, white, flat back, size 630 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand complete all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. including making good to floor as in repair complete all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. including making good to floor complete all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor after and including demolition of PCC / lime concrete bedding of existing pan as in repair complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor as in repair complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
Refixing old 110mm bore PVC (SWR) pipe & connections in new or old position (wall, ceiling, floor etc.) with new fittings etc after and including taking up or down existing PVC pipe and cleaning the same for reuse complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor after and including dismantling of existing unserviceable CI pipe complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor complete all as specified and directed.
S&F for 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F for 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F for 110mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for LLDPE Sepctic Tanks, on lide LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, vent shaft, connection etc complete for fixing in any type of including connection etc vent shaft complete upflow filter including media etc complete for 10 users all as specified and directed.
M&L for sokage wells of size 1.2m dia X 1.5m effective depth (internal), excavation in any type of soil, foundation in PCC (1:3:6) , walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of brick masonary in CM, RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/CWC complete with brick bats complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 150mm bore including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and directed.
M&L for 150mm bore salt glazed stone ware drain pipe grade 'A' laid in trenches and jointed in cement mortar (1:1) complete all as specified and directed.
S&F for 100mm bore sand cast iron soil, waste and vent pipes in any length with or without ears with cement joints, laid in trenches or in floors or fixed to walls after and including dismantling of CI pipe complete all as specified and directed.
S&F for 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete all as specified and directed.
S&F for 100 mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
All as per Item No.154.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular socket 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for ceiling rose , three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for batten holder /angle lamp holder, PVC/polycarbonate type, ISI marked complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Crompton as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed
S&F for MCB, SPN, 40 Amps to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 16 sqmm, 4 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit and chase cutting shall be measured as one unit)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, BEE 5 Star rated, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing complete all as spcified and directed. (Make: Havells/Crompton Greaves /Racold as approved)
M&L for 40mm dia pipe (medium grade) made of galvanised iron in any length including embedded in wall both ends duly welded mild steel hold fast at both ends of GI pipe including providing PCC work (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
Kiran Traders
SANKAR TRADERS
TAMALIKA ENTERPRISE
REMCO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .