| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.2 LAccepted-AOC 5 DARSHANI GATE DEHRADUN PIN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹6.9 L+₹47,711 (7.42%)Rejected-Finance 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹8.3 L+₹1.9 L (29.7%)Rejected-Finance | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹8.6 L+₹2.1 L (33.0%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest |
| Sl No | Description | Qty | Unit | Bedi Refrigeration Works L2 | Tarachand gurudutt L1 | G S CONSTRUCTIONS L3 | trinity construction L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Identifying and rectifying the minor defect/complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection pertaining to all type of Air conditioner/ desert cooler/ Water Coolers/Refrigerator / Deep Freezer of any type and any capacity including servicing, cleaning, and removing dust by air blower and washing with required solution complete all as specified and directed for the item included following:-.
(a) All T & P and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily as directed.
(b) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the rate of quoted item.
(c) Any part need to be replacement will be measured and paid seprately as per respective item of schedule. | 180 | Each job | 120 ₹21,600 Lowest | 140 ₹25,200 | 299 ₹53,820 | 150 ₹27,000 |
| 2.00 | WATER COOLERS
S&F in repair sealed compressor unit of any make any type for water cooler of cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing with new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and charging the gas R-22 / R-134 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed. | 5 | Each | 3,500 ₹17,500 | 4,000 ₹20,000 | 4,199 ₹20,995 | 1,500 ₹7,500 Lowest |
| 3.00 | All as per item No. 02 here in before but for water cooler of capacity 60 Ltrs/hr complete all as specified and directed | 3 | Each | 4,000 ₹12,000 | 4,300 ₹12,900 | 4,335 ₹13,005 | 2,000 ₹6,000 Lowest |
| 4.00 | All as per item No. 02 here in before but for water cooler of capacity 150 Ltrs/hr complete all as specified and directed | 2 | Each | 4,500 ₹9,000 | 4,500 ₹9,000 | 4,665 ₹9,330 | 3,000 ₹6,000 Lowest |
| 5.00 | S&F in repair potential relay box type for water cooler of any capacity complete all as specified and directed | 20 | Each | 100 ₹2,000 | 100 ₹2,000 | 99 ₹1,980 Lowest | 300 ₹6,000 |
| 6.00 | S&F in repair relay current type, for water cooler of any capacity complete all as specified and directed | 15 | Each | 100 ₹1,500 Lowest | 100 ₹1,500 Lowest | 154 ₹2,310 | 900 ₹13,500 |
| 7.00 | S&F in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long as per sample kept in GE office complete all as specified and directed. | 20 | Each | 120 ₹2,400 | 111 ₹2,220 Lowest | 154 ₹3,080 | 350 ₹7,000 |
| 8.00 | S&F in repair Over load protector assembly complete all as specified and directed. | 40 | Each | 100 ₹4,000 Lowest | 100 ₹4,000 Lowest | 145 ₹5,800 | 200 ₹8,000 |
| 9.00 | S&F in repair float valve assembly suitable for 15mm bore of PVC rigid type complete with ball, fixed to water cooler with threaded GI/PVC nipple washer, check nut etc complete all as specified & directed. | 35 | Each | 200 ₹7,000 | 100 ₹3,500 Lowest | 165 ₹5,775 | 250 ₹8,750 |
| 10.00 | S&F in repair PVC connection rigid type 450mm long 15mm bore, with adopter at both ends complete all as specified and directed . | 40 | Each | 50 ₹2,000 | 40 ₹1,600 Lowest | 65 ₹2,600 | 200 ₹8,000 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
4 Jul 2025, 6:00 pmClosed
GE Clement Town
GE Clement Town MES Dehradun
REPAIR/ MAINT OF AIR CONDITIONER, WATER COOLER, REFRIGERATOR AND DESERT COOLERS WITH CONNECTED ITEMS UNDER GE CLEMENT TOWN
2025_MES_712950_1
GE/CLT/ of 2025-26
Open Tender
Civil Works
Item Rate
180 days
GE Clement Town
Class E Cat c(i)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town
₹30,000
Yes
20 Sept 2025
6 Jun 2025
11 Jul 2025
6 Jun 2025
4 Jul 2025
20 Jun 2025
Amount
Identifying and rectifying the minor defect/complaints of any type and nature such as rectification of faulty electric circuit, tightening of loose wiring & connection pertaining to all type of Air conditioner/ desert cooler/ Water Coolers/Refrigerator / Deep Freezer of any type and any capacity including servicing, cleaning, and removing dust by air blower and washing with required solution complete all as specified and directed for the item included following:-. (a) All T & P and labour team required comprising of Nos of trained electricians & helpers will be provided by the contractor daily as directed. (b) Cost of minor stores such as screws,clamps,insulation tapes,nuts/bolts, nail of required size etc shall be deemed included in the rate of quoted item. (c) Any part need to be replacement will be measured and paid seprately as per respective item of schedule.
WATER COOLERS S&F in repair sealed compressor unit of any make any type for water cooler of cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, and fixing with new sealed compressor unit by tightening the foundation nuts and bolts and connecting suction and discharge line with gas welding work etc and checking the leakage in the system and charging the gas R-22 / R-134 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed.
All as per item No. 02 here in before but for water cooler of capacity 60 Ltrs/hr complete all as specified and directed
All as per item No. 02 here in before but for water cooler of capacity 150 Ltrs/hr complete all as specified and directed
S&F in repair potential relay box type for water cooler of any capacity complete all as specified and directed
S&F in repair relay current type, for water cooler of any capacity complete all as specified and directed
S&F in repair rubber hose pipe of 25mm bore with clips for outlet tray of water cooler approximately 1.5 Mtr long as per sample kept in GE office complete all as specified and directed.
S&F in repair Over load protector assembly complete all as specified and directed.
S&F in repair float valve assembly suitable for 15mm bore of PVC rigid type complete with ball, fixed to water cooler with threaded GI/PVC nipple washer, check nut etc complete all as specified & directed.
S&F in repair PVC connection rigid type 450mm long 15mm bore, with adopter at both ends complete all as specified and directed .
M&L for replacement of old condenser of capacity 36 microfarad fins type with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete all as specified and directed.
Supply and fixing in repair fan motor of 1/6 HP capacity water cooler complete all specified and directed.
Supply and fixing in repair push type self closing tap 15mm dia brass chromium plated for water cooler complete with all accessories washers , rubber packing etc complete all as specified and directed.
S&F in repair Thermostate suitable for water coolers of cap 10°C to 30°C complete all as specified and directed.
S&F in repair steel tray alongwith rubber gasket, waste coupler and GI elbow with check nut of 32 mm dia including necessary brazing work suitable for single tap water cooler of 40/80 litre capacity complete all as specified and directed.
All as per item No 15 here in before but for double tap water cooler of capacity 60/120 litre complete all as specified and directed
M&L for making the system leak proof and charging of gas R 22/ R-134 as required in water cooler of capacity 40/80 Ltr including replacement of drier and capillary tube and testing on load complete all as specified and directed.
M&L for making the system leak proof and charging of gas R 22/ R-134 as required in water cooler of capacity 60/120 Ltr ,150/150 Ltr including replacement of drier and capillary tube and testing on load complete all as specified directed.
M&L Dismantling of water cooler of any capacity and taking out complete internal assembly ie. Inner tank, inlet and out let connection etc and descaling with chemical agent including cleaning and washing and reassembling with same position and making the tank leak proof by necessary brazing/welding work with gasket etc complete all as specified and directed
S&F in repair of water cooler inner tank made of stainless steel as per existing capacity (60/80Ltrs) & size with necessary gaskets complete set with drilling work fixing with nut,bolts & washer etc complete all as specified and directed
Supply and fixing in repair PVC fan blade of 250/300mm for water cooler complete all as specified and directed.
M&L for repairing of the water cooler body front side by cutting the worn out stainless steel sheet and fixing new stainless steel sheet of 20 SWG cut in shape and fixed to frame with suitable fixing arrangement including welding/brazing complete all as specified & directed.
Supply and fixing runing capacitor 20 mfd capacity for water cooler complete all as specified and as directed.
Supply and fixing runing capacitor 10 mfd capacity for water cooler complete all as specified and as directed.
AIR CONDITIONERS S&F in repair sealed compressor unit for any make and any type of Air Conditioner, window/Split type, 1.5 ton capacity, by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, and fixing of new sealed compressor unit by connecting suction and discharge lines with gas welding/brazing work including checking the leakeage in the system and charging the gas R -22/ R-410 upto required pressure and tightening foundation nuts & bolts etc complete all as specified and directed.
All as per Item No 25 but for air conditioner window/split type, 2 ton capacity, complete all as specified and directed.
S&F in repair Electric blower Motor of capacity 1/8 HP for Air conditioner window type/split type 1.5 ton/02 ton capacity complete all as specified and directed.
S&F in repair Thermostate of capacity 16°C - 30°C with regulating knob for AC window/split type, working on SP, 230V, AC complete all as specified and directed.
S&F in repair evaporating coil assembly with copper tube for window type AC of capacity 1.5 ton complete all as specified and directed.
S&F in repair condensing coil assembly with copper tube for window type AC of capacity 2.00 ton complete all as specified and directed.
S&F in repair copper pencil strainer of requisite length of dia 6.25mm (min) complete all as specified and directed.
S&F in repair PVC blade for blower motor for window type AC/Split AC of Capcity 1.5 TR/ 02 TR complete all as specified and directed.
S&F in repair of PCB circuit with remote control for air conditioner of capacity 1.5/2 ton complete all as specified and directed at site.
S&F in repair starting capacitor 45 mfd, working voltage 275 volts, 50 Hz, AC suitable for window type room AC of capacity 1.5 TR/2.00TR & Water cooler cap 40, 60 ltr complete all as specified and directed.
S&F in repair running capacitor 36 mfd 440 volts, AC 50 Hz, type SMRC suitable for room AC (Capacity 1.5 TR / 2.00 TR) complete all as specified and directed.
All as per item No.35 here in before but 45 mfd complete all as specified and directed.
S&F in repair Metal clad plug top, 3 pin , 20 amps, 230 volts complete all as specified and directed.
S&F repair single pole and neutral enclosure with metal clad plug and socket 20 Amps and one single pole MCB 25 Amps complete all as specified and directed
S&F in repair PVC front grill suitable for window type room AC of 1.5 ton/ 2 ton capacity complete all as specified and directed.
S&F in repair three core, 2.5 Sqmm copper wire PVC insulated unsheathed,multistrand drawn through the PVC conduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as specified and directed.
All as per item No-40 here in before but of size 4 Sqmm and -ditto-.
S&F in repair MCB single pole, 240 volts,'B' series , 10 KA breaking capacity & connection with aluminium/copper lugs complete all as specified and directed for the following capacity :-
16 to 25 amps rating.
40 amps rating
S&F in repair MCB, single pole & neutral, 240 volts, 'C' series, 10 KA breaking capacity & connection with aluminium/ copper lugs complete all as specified and directed for the following rating :-
32 amps rating.
40 amps rating.
M&L for Re-charging of refrigerant gas (R-22) for window type AC /split Type AC of Cap 1.5/2.0 after vaccuming dehydration, leak testing of the system as per standard practice, testing for proper cooling effects and satisfactory performance complete all as specified and as directed as per following type AC:-
Window AC/ Split AC 1.5 Ton capacity
Window AC/SplitAC 2 Ton capacity
Supply and fixing in repair relay, box type, for Air Conditioner window/split type of cap 1.5 Ton complete all as specified and as directed.
S&F in repair air filter for split type Air conditioner of 1.5/2 ton capacity complete all as specified and directed at site.
S&F in repair air filter washable of Nilon mesh suitable for window type air conditioner of 1.5/2 ton capacity complete all as specified and as directed.
S&F in repair sensor remote switch for AC 1.5/2 ton cap complete all as specified & directed.
Taking out the old/unserviceable heating/cooling unit from the machine of Air conditioner of 1.5/2 ton capacity and S&F reversable unit (Hot and Cold) complete all as specified & directed.
S&F copper pipe with insulation of size 1/2", 1/4" for Split AC of 1.5/2 ton capacity complete all as specified and directed.
All as item No 51 above but size 3/8", 5/8" and -ditto-.
Supply and fix stand set ( GI bracket of suitable size) for outdoor AC unit of capacity 1.5/2 ton capacity complete all as specified and directed
M&L for disconnecting, dismantling of existing split/ window type AC 1.5 /2 TR & refixing the same at new location including gas charging complete all as specified & directed.
DESERT COOLERS S&F in repair Vertical / submersible pump 100 watt capacity operating on Single Phase, 230 Volts, 50 HZ, AC of any type of Desert Cooler, complete all as specified & as directed.
S&F in repair Desert cooler fan motor of capacity 1/7HP operating on Single Phase 230 Volts, 50 HZ, AC with fan blade and mounting Kit complete all as specified and directed.
S&F in repair for PVC pipe 15mm bore of length 450mm standard quality for desert cooler complete with fixing arrangement complete all as specified and directed.
M&L for wood wool pad/ Khas root pad of desert cooler as approved by GE of 3000/4000 CUM/Hour capacity of suitable size including taking down old unserviceable pads of any type complete all as specified and as directed.
S&F in repair 1.5 Sqmm, 3 core copper wire PVC insulated sheathed drawn through the PVC conduit/ PVC flexible pipe complete with suitable size of copper lugs etc complete all as directed.
REFRIGERATORS S&F in repair compressor refrigerator of 165/175/180/190/230 ltrs capacity and fixing new sealed compressor unit, brazing work, making the system leak proof, vacuumising and charging with gas R-134 and testing complete all as specified directed .
All as per item No 61 here in before but for refrigerator of 260/280/286/ 290 ltrs capacity and -ditto-.
All as per item No 61 here in before but for refrigerator of 310/315/320 ltrs capacity and -ditto-.
Supply and Fixing in repair relay box type for refrigerator of capacity 165/190/260/280/315 litre complete all as specified & directed.
Supply and fixing in repair of Thermostateic auto defrost switch with knob for refrigerator of capacity 165/190/260/280/315 litre complete all as specified and directed.
M&L for removing the burnt/defective sealed compressor unit of any make from any type of deep freezer unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of capacity 320/400 litre relay box by connecting suction and discharge lines with gas welding/brazing work etc.and tightening foundation nuts & bolts etc and charging of gas upto the required pressure complete all as specified and directed.
M&L for charging refrigerant gas R-22/R-134 in Deep freezer of cap 200/250/320/400 ltrs complete all as specified and directed.
S&F in repair Vegetable tray as per sample and suitable for refrigerator of capacity 165/220/315 Ltr complete all as specified and as directed.
S&F Evaporator suitable for Voltas/Godrej refrigerators capacity fixed in repairs for 165/290/315 ltr capacity complete all as specified and as directed.
M&L for replacement of over load starting relay kit suitable for 165/280/315 Ltrs capacity refrigerators of any make and testing complete all as specified and directed.
M&L for replacement of Fan motor of capacity 12 volt, 5 watt, 240 volts,SP for frost free freeze complete all as specified and as directed.
M&L for charging refrigerant gas R-22/R-134 in refrigerator of cap 165/286/310 ltrs complete all as specified and directed.
M&L of electronic chip(PCB) including defrost timer,biometal for refrigerator of capacity 165/180 ltrs complete all as specified & directed.
S&F in repair of freezer to refrigerator of 165/190/260/315 litres capacity complete all as specified & directed.
Supply and fixing Plug top, 3 pin, 15 Amp, SP, 230V, fixed in repairs complete all as specified and as directed.
M & L for removing the blockage in evaporating coil of Deep Freezer of capacity 320/400 litre complete all as specified and as directed.
Supply and fixing in repair Plug top, 3 pin, 05 Amp, SP, 230V, fixed in repairs complete all as specified and as directed.
VOLTAGE STABILIZER Taking down of defective/burnt stablizer from various locations under GE Clement Town of capacity 1 to 5 KVA, single phase and Reinstalation of Volatage stablizer after repair of the defective parts and winding of burnt transformer alongwith replacement with new parts/ winding and testing complete all as specified and directed.
S & F in repair of relay 24 Volts 250 Ohms complete all as specified and as directed.
S & F in repair condensor of existing capacity complete all as specified and as directed.
S & F in repair transistor of existing capacity complete all as specified and as directed.
S & F in repair circuit card of existing capacity complete all as specified and as directed.
S & F in repair of transformer winding (copper) complete all as specified and as directed.
S & F in repair of Volt meter as per existing complete all as specified and as directed.
S & F in repair of Indicator lamp (red/green) complete all as specified and as directed.
S & F in repair of terminal strip complete all as specified and as directed.
S & F in repair Push button 03 Nos. (Per set) complete all as specified and as directed.
NOTES :- 1. For the items for which specifications not mentioned any where in the tender, the BIS specifications shall be followed.
Bedi Refrigeration Works (BID ID -3338959)
G S CONSTRUCTIONS (BID ID -3347284)
trinity construction (BID ID -3342490)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .