Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC ACEEPTED BEING LOWEST TENDER | |
| 2 | L2₹24.1 L+₹45,984.59 (1.94%)Rejected-AOC A 1 BLOCK 2 HATHITHAN HATHITHAN VILLAGE TOWN JALALNAGAR CITY SHAHJAHANPUR SHAHJAHANPUR UTTAR PRADESH 242001 INDIA | SHAHJAHANPUR | UTTAR PRADESH | 242001 | L2 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 3 | L3₹24.6 L+₹88,367.34 (3.73%)Rejected-AOC | L3 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER | |
| 4 | L4₹25.3 L+₹1.7 L (7.09%)Rejected-AOC | L4 | Rejected-AOC REJECTED BEING NOT LOWEST TENDER |
Tender Value
₹29.6 L
EMD Value
₹59,120
Closing Date
13 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I RND DEHRADUN
GE I RND DEHRADUN DEAL RESIDENTIAL COMPLEX RAIPUR ROAD DEHRADUN 248008
PROVISION OF HARD STANDING FOR OUT DOOR INTEGRATION AND TESTING FACILITY IN FORNT OF SATCOM BLDG (P-36) IN TECH AREA DEAL UNDER GE(I) RN D DEHRADUN
2021_MES_483547_1
GE(I)RND/9075/E8/21-22
Open Tender
Civil Works
Item Rate
180 days
DEHRADUN
Class D Category b (i) FOR UNENLISTED CONTRACTOR (i) Enlistment criteria may be seen in Para 1.4 of section of Part I of MES Manual on contracts-2007 (Reprint 2012) as available in all MES formations (ii) Copy of police verification /passport.
6 documents required · 6 mandatory
₹500
Yes
GE I R N D DEHRADUN
₹59,120
Yes
13 Dec 2021
23 Oct 2021
15 Nov 2021
23 Oct 2021
13 Nov 2021
30 Oct 2021
23 Oct 2021 - 30 Oct 2021
60 days
Amount
M &L for surface dressing n. exc. 15 cm deep in soft/loose soil, complete all as specified and directed.
M &L for hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface using broken stones or boulders, complete all as specified and directed.
M & L 100 mm thick PCC 1:4:8 type D-2 using 40mm graded aggregate as in sub base, complete all as specified and directed.
M&L 150 mm thick Cement concrete work in pavement/hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less complete all as specified and directed.
M & L for Rubber Moulded precast conctete interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 Grade, with gery cement and no pigment, laying in floors over sand cushion etc completed all as specified.
M & L Sand filling under floors or in foundations including watering and consolidation, etc complete all as specified and directed.
M&L Brick work with sub class B bricks straight or curved on plan exc 6m mean radius built in CM 1:6 Complete all as Specified and directed
M & L rendering 15mm thick on wall in cement mortar 1:4 finished fair and even smooth without using extra cement complete all as specified.
M&L preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of suitable primer on walls. complete all as specified and directed.
S& F Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165,etc complete all as spd and directed.
M&L for preparation of new or previously untreated steel surfaces exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and directed.
Demolition of PCC in ground floors & pavings n exc 15 cm thickness (below or above ground level) (unreinforced) Complete all as specified and directed.
Excavation in trenches in any type of soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. all as specified and directed by Engineer-in-Charge including removing cable protection covers/ bricks & stacking serviceable bricks for reuse and disposal of unserviceable covers within 50 m all as directed. Note : (i) Excavation shall be made carefully in order to avoid damage of existing cables and brick protection. (ii) The excavation work may be carried out in short lengths for locating fault in under ground cables at different locations
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers of 25 cm thick after the cables etc. are laid, jointed and tested complete all as specified and directed by Engineer-in-Charge.
M&L for Removal of surplus excavated soils not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Material & labour for sand filling with clean dry find sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed by Engineer-in-Charge.
M&L for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed by Engineer-in-Charge.
Supplying, laying & jointing GI water tubing, 50 mm bore, medium grade as in sleeving etc laid in trenches / ducts etc. complete all as specified and directed by Engineer-in-Charge.(MAKE : TATA/JINDAL/TT SWASTIK)
Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of size 35 Sqmm, 3.50 Core laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed .Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armoured electric power cable (heavy duty) with aluminum conductor for working voltage upto and including 1100 Volts, cross sectional area of size 16 Sqmm, 4.00 Core laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed.Make:Havells/CCI/ICL/GLOSTER/Incab/Nicco/Polycab/Plaza) (NOTE: Earth work, sand cushioning, pipe, clamps for holding cables and brick protection shall be measured and paid separately )
Supply and fixing double compression copper stainless steel gland for fixing cable in panel of 3. core, 25 to 35 sqmm size complete all as specified and directed
Supply and fixing double compression copper stainless steel gland for fixing cable in panel of 3. core, 06 to 16 sqmm size complete all as specified and directed
M&L for chemical Earthing with copper earth plate 90x60x6 mm and Copper Earthing Strip of size 32x6 mm for sensitive equipment for Lab, requirement of earthing less than 1 Ohm all as shown in electrical plate No 3 of SSR Part-I (02 Nos for LT panel and 1 Each for 03 Nos Juncation box) complete all as specified and directed
Supply, install, commissioning and testing LT panel cubical floor mounted type of suitable size as per latest norms, made out of 3.15mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 Amps rating made of copper strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 Volts, 50 Hz AC supply suitable for and including the following :- (a) MCCB 4 pole, 415 Volts, 100 Amps rating with rupturing capacity 25 KA - 01 No for incoming. (b) MCCB 4 pole, 415 Volts, 63 Amps rating with rupturing capacity 25 KA - 04 No for Junction boxes (1 No Spare) (c) Indicator set RYB - 01 No set of 03 pieces only. (d) Multifunction digital panel meter suitable to display3 Amps, volts, frequency etc., - 01 No.including CTs of appropriate rate. (e) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply, install, commissioning and testing junction box floor mounted type of suitable size as per latest norms made out of 3.15mm thick MS sheet duly painted with two coats of synthetic enamel paint powder coated, bus bar 200 Amps rating made of copper strip duly drilled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 Volts, 50 Hz AC supply suitable for and including the following :- (a) MCCB 4 pole, 415 Volts, 63 Amps rating with rupturing capacity 25 KA - 01 No for incoming (b) Metal clad socket 5/15 amp combination 3 pin single phase - 04 Nos (c) Metal clad socket 05 amp single phase, 3 pin - 04 Nos (d) Metal clad socket 32 amp 3 phase 4 pin - 04 Nos (e) Digital Voltmeter 3 Phase AC 0 – 500 Volts.Qty -01 No. (f) Indicator set RYB - 01 No set of 03 pieces only. (g) Multifunction digital panel meter suitable to display3 Amps, volts, frequency etc., - 01 No.including CTs of appropriate rate. (h) All accessories prewired with suitable size copper conductor cable or strip including foundation as per manufacturer instruction all as required and directed.
Supply and fixing 4 Pole MMCB of capacity 100 Amp, 415 Volt with rupturing capacity 25 KA for fixing at existing LT panel.
M/S WASEEM KHAN CONTRACTOR
M/S DHYANI CONSTRUCTION CO.
Gaur Construction Co
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .