Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC H NO 1300 PUSHP VIHAR COLONY GUPT GANGA ROAD KANGRA 176001 | KANGRA | KANGRA | HIMACHAL PRADESH | 176001 | L1 | Accepted-AOC BIDDER IS L1 | |
| 2 | L2₹16.3 L+₹23,765 (1.48%)Rejected-Finance | L2 | Rejected-Finance l2 | |
| 3 | L3₹16.3 L+₹26,080 (1.62%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹16.2 L
EMD Value
₹32,400
Closing Date
28 Sept 2022, 10:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Elect. Division HPPWD Palampur
C/O School of Nursing at Dr.RPGMC Tanda in Distt. Kangra (HP) (SH- Providing E.I. in Basement floor and Additional work therein)
2022_PWD_65278_2
Elect. Division HPPWD Palampur
Open Tender
Electrical Works
Item Rate
365 days
Kangra at Tanda in Distt. Kangra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
₹32,400
27 Oct 2022
21 Sept 2022
28 Sept 2022
21 Sept 2022
28 Sept 2022
21 Sept 2022
120 days
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required.Make: KEI/Plaza/Anchor/ Anchor (Roma Plus)/Schneider (Livia)/ Legrand (Myrius) /L&T(Entice).
Group C.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.Make: KEI/SCI/Havells/plaza.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.Make: KEI/SCI/Havells/plaza.
2x1.5 Sq. mm.
2x4.0 Sq. mm.
Wiring for circuit/sub-main wiring alongwith earth wire with following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recess steel conduit as required Make: KEI/SCI/Havells/plaza.
2X10 sqmm + 1X6.0 sqmm
Supply and drawing following size of PVC insulated, heat resistant, flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in existing surface / recessed, Steel/PVC conduit as required.
3x1.5 Sq. mm.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.Make:- Legrand (Myrius)/ Schneider(Livia)/Anchor Roma (Plus)
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.Make:- Legrand (Myrius)/ Schneider(Livia)/Anchor Roma (Plus)
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/ XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below ground level including excavation, sand cushioning, protective covering and refilling the trench etc.as required,Make: KEI/SCI/Havells/plaza.
Armoured cable 300 sq. mm (3.5 core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:-Make: KEI/SCI/Havells/plaza.
Armoured cable 300 sq. mm (3.5 core)
Supply and erection of 6 amps. to 32 amps. rating, 240/415 volt 10 KA 'C' curves, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required:-Make:- Anchor /Legrand/ Schenider.
Single pole. Cat-A
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- Anchor /Legrand/ Schenider.
63 Amp. Cat-A.
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make:- Anchor /Legrand/ Schenider.
63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:-Make:- Anchor /Legrand/ Schenider.
Double door-12 way
Double door-16 way
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:-
Exhaust Fan, Light duty, 300 mm sweep, (Domestic)
Exhaust Fan, Heavy duty, 300 mm sweep, (Category-A)
Providing, Installation, testing and commissioning of ceiling fan with modular step type electronic fan regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required.
Ceiling Fan 1200 mm sweep, Category-A
Makes:-Usha (Technic plus minimum 3 star rating / Bajaj (Ultima) / Crompton Greaves
Supplying and fixing 2 Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Earthing with copper earth plate 600mmX600mmX3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc. with charcoal/cock and salt as required
Providing and fixing copper tape 20mm X 3mm thick on parapet or surface of wall for lightening conductor as required ( Vertical Run)
Providing and fixing copper tape 20mm X 3mm thick on parapet or surface of wall for lightening conductor as required ( Horizontal Run)
Supplying and fixing following rating LED Flood Light comes with die cast aluminium housing with frame, toughened glass with PC Lens, cradle mounting and IP66 protection including connections, testing etc. as required complete in all respects.
Flood Light 70 Watt ( Panasonic Item PFLM19708, Wipro, Bajaj make
Supplying and fixing of LED Bulkhead with a nominal system output of 1000 lumens,CCT 6500K Ceiling and wall mount LED bulk head serves as an excellent energy efficient alternative to CFL/ incandescent bulkhead luminaires suitable for surface and wall mounting application as required complete with all accessories, connections, testing and commissioning etc Makes :- Havells, Helonix, C&S as per , Panasonic
LED Bulkhead, 10 Watt
Providing and installation of LED Fixture 600mm X 600mm 36 Watt +/- 1 W Surface mounted with PMMA Diffuser having minimum system lumen efficacy of 100lm/W with CRCA housing and PMMA diffuser with P.F.>0.95, THD<10% CCT 5700 K, CRI 80. The LED shall be tested with LM80-08 Standard with useful life of 50000 Hrs at L70 Wipro Cat no. CRCO10S038HP57G1L1/ Philips/ Panasonic/ Trilux
Surface 2'X2' 36 Watt
Providing and installation of LED fixture 18Watt +/- 1 Watt LED Square surface mounted downlighter Round Shape with minimum system lumen efficiency of 85lm/ watt with power factor ≥ 0.95, THD≤ 20%, CCT- 6000K, CRI 80. The LED with useful life of 50000 Hrs. at L70. THe input voltage range shall be 150V to 270 V, Wipro Cat no. LD80-171-XXX-60-SM, Philips / Trilux/ Panasonic or equivalent make
Providing and installation of IP20 LED Fixture of 20 Watt +/- 1 W Surface mounted 4 feet Batten Fixture with system lumen efficacy of 100lm/W with Aluminium housing P.F.>0.95, THD<10% CCT 5700 K, CRI 80. The LED shall be tested with LM80-08 Standard with useful life of 50000 Hrs at L70. The input voltage range shall be 150V to 270V Wipro Cat no. LL20-281-XXX-ALINE3/ Philips/ Panasonic/ Trilux or equivalent make
LED Batten light 20 W
Providing and installation of IP20 LED Fixture of 40 Watt +/- 1 W Surface mounted 4 feet Batten Fixture with system lumen efficacy of 100lm/W with Aluminium housing P.F.>0.95, THD<10% CCT 5700 K, CRI 80. The LED shall be tested with LM80-08 Standard with useful life of 50000 Hrs at L70. The input voltage range shall be 150V to 270V Wipro Cat no. LL24-541-XXX-57-XX,Make:- Bajaj/ Clair/ Panasonic/ make
LED Batten light 40 W
pankaj saini
JAMWAL ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .