REPAIR / MAINTENANCE OF AIR CONDITIONERS, WATER COOLERS, DEEP FREEZERS AND SUMMER APPLIANCES INCLUDING AC PLANT OF SAMRAT AUDITORIUM UNDER GE (AF) JAMNAGAR NO.2
2026_MES_776208_1
8659/E8
Open Tender
Electrical and Maintenance Works
270 days
GE (AF) JAMNAGAR NO.2
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) JAMNAGAR NO.2
₹80,000
Yes
3 Jul 2026
3 Jul 2026
27 Jul 2026
3 Jul 2026
24 Jul 2026
17 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M & L for servicing of Split type Air conditioner of capacity 1.5/2.0 ton of any model by disconnecting electric connection from its stabilizer or its electric board and remove the front cover or indoor AC unit and cleaning it with pressurized water and nylon brush, refixing the front cover of indoor unit. Remove the outer cover of out door unit and covered the condensing unit with ploythene/plastic cover so that water shall not be entered in the motor while cleaning the unit and filter with pressureized water then apply one coat of descaling solution and clean with wire mesh bursh/nylon brush to the condensing coil of out door unit and greasing of all moving parts. Cleaning of Cooling and condenser coil of indoor and outdoor unit shall be properly carried out without damaging other parts. Checking and making serviceable electrical connection of DBs, Stabilizer, wiring of ACs as per site condition and tightening all electrical connection complete all as specified and directed. Note - Replacement of defective parts with new parts shall be measured and paid seperately under respective items in the schedule. | 135 | Each Job | - | - |
| 2 | Material and labour for Leak testing of cooling coils attached with indoor and outdoor unit of split air conditioner of any capacity and any model uisng CO2/Nitrogen gas, arrest of leakage with brazing of copper pipe and retest again for leakage complete all as specified and directed. | 70 | Each Job | - | - |
| 3 | M & L for charging of refrigerant R-22/R32 gas to air conditioner or as per existing /manufacturer instrcutions suitable for split air conditioner cap 1.5 ton after flushing out the entire refrigerant, vaccum testing of entire closed loop system for 24hrs and charging the unit with specified quantity of gas, as per manufacturer instructions,as mentioned above complete all as specified and directed. | 34 | Each Job | - | - |
| 4 | All as per item No.3 above but for 2.0 ton capacity complete as per manufacturer instructions complete all as specified and directed. | 15 | Each Job | - | - |
| 5Material and labour for maintenance of air conditioner 1.5/2.0 ton capacity, split type unit with replacement of old/unsv spare parts mentioned as under or as per manufacturer instructions including testing on load complete all as specified and directed. | |||||
| 5.01 | S & F in repair over load protector suitable range and capacity | 10 | Each | - | - |
| 5.02 | S & F in repair starting capacitor 80/100/120 mfd suitable for 240 volts 50 HZ AC supply | 17 | Each | - | - |
| 5.03 | S & F in repair running capacitor of 36/45/50/60 + 5/6 mfd suitable for 240 volts 50 HZ AC Supply | 25 | Each | - | - |
| 5.04 | S & F in repair capacitor of 2.5 mfd suitable for suitable for blower fan motor of 1.5/2.0 ton AC | 16 | Each | - | - |
| 5.05 | S & F in repair thermostat switch of suitable suitable for 1.5/2.0 ton AC | 12 | Each | - | - |