| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.9 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L2₹24.7 L+₹1.2 L (5.32%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L-3₹25.2 L+₹1.8 L (7.70%)Rejected-AOC | L-3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹49,600
Closing Date
21 Jan 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C o 56 APO
SPL REPAIR TO BLDG NO T-14 AND T-61 AT MI ROOM COMPLEX OF FD HOSP, PROVN OF 50 USER SEPTIC TANK AND SOAKAGE PIT AT ASCON NODE SINGHPURA AND PROVN OF TOILET BLOCK AT 192 AP AT PATTAN UNDER GE 969 EWS
2020_MES_405244_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
180 days
Pattan
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹49,600
Yes
15 Mar 2021
19 Dec 2020
23 Jan 2021
19 Dec 2020
21 Jan 2021
2 Jan 2021
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises. Complete all as specified and directed by Eng-In-Charge.
Demolition of brick work, PCC block masonary, stone masonary or boulder masonary built in cement mortar including all quins, arches, pillars, etc.Complete all as specified and directed by Eng-In-Charge.
Demolition of cement concrete (un-reinforced) in ground floors and pavings not exc 15 cm thickness (below or above ground level). Complete all as specified and directed by Eng-In-Charge.
Dismantling of wall and ceiling board(fibre, pulp,insulation etc) or insulation board/slabs/blankets, any thickness, including cover fillets. Complete all as specified and directed by Eng-In-Charge.
Dismantling timber scantling 40 sq cm and over in section in any position as in unframed work Complete all as specified and directed by Eng-In-Charge.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings Complete all as specified and directed by Eng-In-Charge.
Taking down chowkat or frames not exc 1.5 Sqm but with shutters of any description (without taking off shutters from the frame).
Excavating in trenches n.exc. 1.5m wide and n.exc 1.5 m in depth, for foundation, laying of cable etc. and getting out hard/dense soil or any type of soil. Complete all as specified and directed by Eng-In-Charge.
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in any type of soil. Complete all as specified and directed by Eng-In-Charge.
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass. Complete all as specified and directed by Eng-In-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm. Complete all as specified and directed by Eng-In-Charge.
Removing excavated material (soil) exc. 250 m but n.exc. 500 m and depositing where directed at a level n. exc. 1.5 m above the starting point.
M & L for providing PCC 1:2:4 type B1 (20mm graded crushed stone aggregate) as in copings, benching, bedplates and the like incl weathering slightly rounded or chamfered angles throating and incl use of necessary formwork complete all as specified.
M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash.
M&L for 75 mm thick PCC 1:4:8 type D-2, using 40 mm graded stone aggregate in sub base of flooring/harstanding. Complete all as specified and directed by Eng-In-Charge.
M&L for 25 mm thick PCC 1:2:4 type B-1, using 20 mm graded stone aggregate, including finishing surface of concrete topping even and rough Complete all as specified and directed by Eng-In-Charge.
M & L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete.
M&L for glazed ceramic tile 300 x 200 x 06-7mm thick (coloured) on vertical surfaces such as skirting, dados etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 10 mm thick plaster in cement and sand mortar 1:4. Complete all as specified and directed by Eng-In-Charge.
M&L for non skid coloured ceramic tiles 300x300x 6-7mm thick in floor etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:4, Complete all as specified and directed by Eng-In-Charge.
M & L for Vitrified Ceramic tiles 10 mm thick dark shade (square/ rectangular) polished, area of each tiles exceeding 0.36 sqm not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles over and including 15 mm thick screed bed in cement and sand mortar 1:4, Complete all as specified and directed by Eng-In-Charge.
M&L for 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in plinth protection and similar works including finishing the surface of concrete topping even & fair, without using extra cement Complete all as specified and directed by Eng-In-Charge.
M&L for brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 Complete all as specified and directed by Eng-In-Charge.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan any radius in half brick thick wall with old size bricks built in cement mortar 1:4 Complete all as specified and directed by Eng-In-Charge.
S&F 6mm thick veneered decorative plywood , grade 1(with BWR resign) with decorative face veneers on one side faces, , fixed with nails to timber frame work in ceiling.
S&F 6mm thick veneered decorative plywood , grade 1(with BWR resign) with decorative face veneers on one side faces, , fixed with nails to frame work on walls.
M & L for 6 mm thick ply wood, grade, BWR type BB, fixed with nails to timber frame work as in wall etc, Complete all as specified and directed by Eng-In-Charge.
M & L for 6 mm thick ply wood, grade, BWR type BB, fixed with nails to timber frame work as in ceiling etc, Complete all as specified and directed by Eng-In-Charge.
M&L for 2nd class soft(wood) as in scantling clean sawn, fixed to timber frame work. Complete all as specified and directed by Eng-In-Charge.
M&L for painting to new wood or wood based surfaces of wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, with two coats of synthetic enamel paint over one coat of primer Complete all as specified and directed by Eng-In-Charge.
M & L for 0.63mm thick galvanised corrugated or semi-corrugated mild steel sheeting with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc with grade of zinc coating in roofing Complete all as specified and directed by Eng-In-Charge.
All as per item No. 31 above but except sheets.
M & L for 0.80mm thick plain Galvanised mild steel sheeting, in ridges, hips, facia boarding, valley gutters, drip and straight flashings (length and girth as fixed with grade of zinc coating fixed with new J-hooks/L-hooks/cranked hook bolts etc. Complete all as specified and directed by Eng-In-Charge.
M&L for preparation of new steel surfaces of any description over 10 cm width or girth and priming with red oxide zinc chrome and painting with two coats of synthetic enamel paint on Steel sheeting as in roofing Complete all as specified and directed by Eng-In-Charge.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint on steel sheeting as in roofing. Complete all as specified and directed by Eng-In-Charge.
S & F for 1st Class softwood in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints. Complete all as specified and directed by Eng-In-Charge.
S&F 35mm thick, 1st class soft wood plain, framed, panelled shutters (any number of panels) with panels of veneered particale board or plywood lock rail and panel of 12mm veneered particle board with commercial or bison board.
S&F 30 mm thick, 1st class Softwood , glazed & skeleton shutters, open rebated & prepared to receive glass, gauze etc. (without sash-bars), edges of framing plain, chamfered or rounded fitted with cut and metred beads for securing glass etc. for windows and ventilators.
S&F butt hinges, 100 mm long medium weight, cold rolled mild steel, ISI marked Complete all as specified and directed by Eng-In-Charge.
S&F butt hinges, 50 mm mm long Complete all as specified and directed by Eng-In-Charge.
S&F aluminium handles cast type anodised of size 150mm long ISI marked Complete all as specified and directed by Eng-In-Charge.
S&F aluminium handles cast type anodised of size 100mm long ISI marked Complete all as specified and directed by Eng-In-Charge.
S&F 150mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked Complete all as specified and directed by Eng-In-Charge.
Extra over hammer dressing to face stone and dressing of face beds with maximum depression on face from straight edge n.exc 40mm. Complete all as specified and directed by Eng-In-Charge.
M&L for providing cement concrete Type B-1, 1:2:4 (20 mm graded crushed stone aggregate) as in copings, plinth Course, bond stones including use of form work. Complete all as specified and directed by Eng-In-Charge.
M&L for rendering 10 mm thick in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces. Complete all as specified and directed by Eng-In-Charge.
S&F roof trusses, trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (unframed work). Complete all as specified and directed by Eng-In-Charge.
M&L for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, sheets shall be conforming to IS make. Complete all as specified and directed by Eng-In-Charge.
S & F for 2nd Class Hardwood in Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered,put together with glue pinned at joints. Complete all as specified and directed by Eng-In-Charge.
S&F painting to new wood or wood based surfaces of any description not otherwise described over 10 cm in width or girth including preparation of surfaces, priming with pink primer (one coat) finished with two coats of synthetic enamel paint. Complete all as specified and directed by Eng-In-Charge.
M&L for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement complete all as shown in drawing of relevant item in MES, schedule Part-II , 2010 as specified and directed by Eng-In-Charge.
S&F 3 mm thickness sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane. Complete all as specified and directed by Eng-In-Charge.
S&F 200mm long, aluminium anodised, barrel tower bolts, of extruded section ISI marked. Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) branch piece equal or unequal, plain including jointing with solvent cement 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) branch piece equal or unequal, plain including jointing with solvent cement 110 mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) vent cowl, plain including jointing with solvent cement 75mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) floor bend, plain including jointing with solvent cement 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) reducer pipe piece, plain including jointing with solvent cement 110 mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore Complete all as specified and directed by Eng-In-Charge.
S & F for PVC (SWR) gully trap, plain with grating including jointing with solvent cement 110 mm bore Complete all as specified and directed by Eng-In-Charge.
S&F vitreous China squatting pan “Orissa pattern” size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe) with CI ‘P’ trap of long arm of suitable size including connection to flush pipe, anti symphonic pipes etc , Complete all as specified and directed by Eng-In-Charge.
S&F in repalcement of PVC low level flushing cistern, valveless, syphonic action type, 10 litres capacity with inlet, ball valve float and handle with and including brackets & PVC bend pipe 90 cm long etc, supplied and fixed, Complete all as specified and directed by Eng-In-Charge.
S & F Vitreous China urinal ,half stall type white (excluding flushing cistern,flushing pipe and waste pipe). Complete all as specified and directed by Eng-In-Charge.
S & F Vitreous china wash basin, white, flat back, size 550x400mm including pillar tap, waste fitting chromium plated brass and rubber plug, porcelain stopper, a pair of CI brackets, waste pipe and pillar tap etc, fixed. Complete all as specified and directed by Eng-In-Charge.
S&F PVC connection 15 mm size, of length 450 mm, with PTMT nuts supplied and fixed. Complete all as specified and directed by Eng-In-Charge.
M&L for RCC Hume pipe septic tank, exc in ordinary soil, in PCC 1:4:8 below foundation, vent shaft and sludge chambers etc complete for 5 users. Complete all as specified and directed by Eng-In-Charge.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.2 M dia X 1.5 M effective depth. Complete all as specified and directed by Eng-In-Charge.
S&F 15 mm bore 3-layer PP-R Polypropylene random copolymer) pipes SDR 7.4 & SDR 11 UV stablised and antimicrobial welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc.
S&F 15mm bore dia bib tap cast copper alloy with crutch or bytterfly handle, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed.
Supply and fix 15mm bore dia stop/gate valve cast copper alloy with crutch or bytterfly handle, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed but fancy type
Supply and fix 20mm bore dia stop/gate valve cast copper alloy with crutch or bytterfly handle, fancy type, chromium plated, screwed down, screwed for iron pipe or for brass ferrule and fixed but fancy type
S&F 500 Ltr rotational moulded polythene water storage tank, three layered (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I and directed by EIC.
M&L for 12000 ltrs capacity FPR moulded anaerobic septic tank for an anaerobic design in which bacteria treats waste under most favourable conditions. The process effectively prevents rapid accumulation of sludge and suspended soilds from passing through the system untreated with innovative engineering design of the inlet-outlet short circuit of wastewater which is prevented to ensure long and enough retention time for effective treatment . Thus the effluent does not contain any solid or scum that could clog up the pipe line. The septic tank is buried underground , soilid and liquid waster flow into it. Heavy solid waste settle to the bottom of the septic tank (Khown as sludge). The liquid wastes are also held in the septic tank while bacteria break down solids into liquids in an anaerobic environment, This process is known as primary treatment some bacteria and viruses are absorbed into solid particles and held in the sludge or scum layers, allowing for limited removal of disease causing organism at the stage. All that has to be done for fitting the tank is to fill the tank with water, connect the drain line to the inlet and outlet to the soak pit. Cover the manholes with the lids provided and tank is ready to use incl PCC ;4:8 below foundation and vent shaft connection etc. incl PVC (SWR) pipe for laying in trenches and manhles from bldg to septic tank.Complete all as specified and directed by Engr-in-charge.
M&L for 6000 ltrs capacity FRP moulded anaerobic soak pit for and anaerobic treatment. The soak pit latrines are rather rudimentary sanitation facilities at least serving to contain the spread of faecal organisms from the night soild organism and faecal orgasisms in the soak pit. All that has to be done for fitting the tank is to fill the tank with water connect the drain line to the inlet and outlet to the soak pit. Cover the manholes with the lids provided and tank is ready to use incuding PCC 1:4:8 below foundation and vent shaft conncection tec including PVC (SWR) pipe for laying in trenches from septic tank to soakage well. Complete all as specified and directed by Engr-in-charge.
E/M Portion:- Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet, bends,elbows,reducers, MS box dully painted etc. and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
All as per sr item no. 78 above but One 3 pin 5 Amp switch socket outlet on independent board.
All as per sr item no. 78 above but One 3 pin 5 Amp switch socket outlet on same board.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. Complete all as specified and directed by Eng-In-Charge.
S&F switch piano Flush type, single pole 6 amp 240 volts, Complete all as specified and directed by Eng-In-Charge.
S&F switch piano Flush type, single pole 16 amp 240 volts, Complete all as specified and directed by Eng-In-Charge.
Supply and fixing socket outlet, 2 in 1,3 pin, 5 A flush type. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing socket outlet, 2 in 1,3 pin, 5 & 15 A flush type. Complete all as specified and directed by Eng-In-Charge.
S&F stepped type electronic fan regulator on the existing sheet, Complete all as specified and directed by Eng-In-Charge.
Taking down fan, ceiling cable end, dismantling blades and removing fan and blades to store. Complete all as specified and directed by Eng-In-Charge.
Hanging only ceiling fan and connecting up incld provision of cable from ceiling rose or connector to fan. Complete all as specified and directed by Eng-In-Charge.
Supply and fixing ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body. Complete all as specified and directed by Eng-In-Charge.
S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting Complete all as specified and directed by Eng-In-Charge.
S&F bell electric, ding dong, AC 230 V, single pole. Complete all as specified and directed by Eng-In-Charge.
S& F VTPN Vertical type distribution boards, 4 way double door, Complete all as specified and directed by Eng-In-Charge.
S & F in repairs MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge.
S & F in repairs MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge.
S & F MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting. Complete all as specified and directed by Eng-In-Charge.
S & F MCB, SP 6-32 Amps 240 Volts Gold plus MCB B Curve. Complete all as specified and directed by Eng-In-Charge.
S & F MCB, SPN 6-32 Amps 240 Volts Gold plus MCB B Curve. Complete all as specified and directed by Eng-In-Charge.
S&F MCB DP, 415 V, 40 Amps with breaking capacity 16 KA,C curve Complete all as specified and directed by Eng-In-Charge.
S&F MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA, optium 1.0 (Fixed TM range). Complete all as specified and directed by Eng-In-Charge.
S&F LED Lamp 15 W. Complete all as specified and directed by Eng-In-Charge.
S&F ultra modern energy saving surface mounted, decorative oval bulkhead edge lit LED 10 W of high brightness. Complete all as specified and directed by Eng-In-Charge.
S & F endura linear leo surface mounted LED tube light fitting 20 W four feet extrd aluminium housing provided with polycarbonate diffuser and intgrtd electronic driver. Complete all as specified and directed by Eng-In-Charge.
M&L for Sub main wiring with 2 runs of 10 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 10 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring Complete all as specified and directed by Eng-In-Charge. Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit will be measured as one length.
M&L for heavy duty electric cables with aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire 4mm dia or tape and overall PVC sheathed 1100 volts grade of cross sectional area 10 sq.mm 2 core. Complete all as specified and directed by Eng-In-Charge.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 16 sq. mm 2 core. Complete all as specified and directed by Eng-In-Charge.
M&L for XLPE insulated heavy duty electric cables with aluminium conductor, 1100 volts grade of cross sectional area 25 sq. mm 3.5 core. Complete all as specified and directed by Eng-In-Charge.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is inclusive of necessary earth work, RFR and removal etc. Complete all as specified and directed by Eng-In-Charge.
Supply and spreading clean, dry sand in trenches for cushioning/ for laying of cable. Complete all as specified and directed by Engineer-In-Charge.
S&F LIVA pendent with 15w LED bulb decorative surface mounting, conical shaped, pink colour. Complete all as specified and directed by Eng-In-Charge.
S&F water storage heater of capacity 25 Ltr BEE 5 star, 230 V AC, 50 Hz incld PVC connection of size 15mm dia & 450 mm long for hot water complete. Complete all as specified and directed by Eng-In-Charge.
Supply and laying sub class 'B' bricks laid across the cable for protection. Complete all as specified and directed by Eng-In-Charge.
Supply and laying GI tubing 40mm bore light grade galvanized with all fitting. Complete all as specified and directed by Eng-In-Charge.
Supply and Fixing GI tubing 25 mm bore medium grade galvanized with all fitting, laid under floors, fixed to wall and providing clamps etc. Complete all as specified and directed by Eng-In-Charge.
Supply and Fixing GI tubing 20 mm bore medium grade galvanized with all fitting, laid under floors, fixed to wall and providing clamps etc. Complete all as specified and directed by Eng-In-Charge.
S&F house service bracket (hook type complete with 3.0m long GI pipe 40mm dia medium grade, two nos. 90 degree bends MS hook and stay or guy. Complete all as specified and directed by Eng-In-Charge.
M/S MANZOOR AHMAD YATOO
M/S ESS EMM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .