| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹57.8 LAccepted-AOC AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | L-1 | Accepted-AOC Lowest Bidder (L-1) | |
| 2 | L-2₹66.1 L+₹8.3 L (14.4%)Rejected-Finance AGARTALA TRIPURA W | AGARTALA | TRIPURA | L-2 | Rejected-Finance High Rate | |
| 3 | L-3₹75.8 L+₹18.0 L (31.2%)Rejected-Finance | L-3 | Rejected-Finance High Rate | |
| 4 | L-4₹77.9 L+₹20.2 L (34.9%)Rejected-Finance DHALESWAR JAIL ASHRAM ROAD AGARTALA TRIPURA W | DHALAI | TRIPURA | 799204 | L-4 | Rejected-Finance High Rate | |
| 5 | L-5₹81.2 L+₹23.5 L (40.7%)Rejected-Finance JAGAHARIMURA AGARTALA WEST TRIPURA | AGARTALA | WEST TRIPURA | TRIPURA | L-5 | Rejected-Finance High Rate |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
5 Jan 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DGM ED-Sonamura, Rabindranagar, Sipahijala Distric
DGM ED-Sonamura, Rabindranagar, Sipahijala Distric
System Improvement of electricity under Electrical Sub-Division Kathalia and Sonamura
2020_POWER_14691_1
1
Open Tender
Electrical Works
Works
180 days
Sonamura
Please refer Tender documents.
3 documents required · 3 mandatory
₹10,000
TSECL Settlement Centralised Account
₹1.4 L
DGM ED-Sonamura, Rabindranagar, Sipahijala Distric
12 Apr 2021
16 Dec 2020
6 Jan 2021
16 Dec 2020
5 Jan 2021
16 Dec 2020
16 Dec 2020 - 23 Dec 2020
24 Dec 2020
180 days
Amount
SUPPLY
Supply of PCC pole as per state practice:- a) 9.0 mtr. Long, working load 250Kg.
b) 8.0 mtr. Long, working load 200Kg.
Supply of 11 KV/LT painted stay set complete direct in earth with 16mm. dia. 1.8 mtr. long painted stay rod, one side formed an eye and welded with internal dia 40 mm with one thimble and other side of the rod each threaded and fitted with 2 nos. of suitable hexagonal nuts and with one round MS washer of size 40 X 40 X 2 mm complete with MS Anchor plate of size 300 X 300 X 8 mm, dimension with centre hole of 18 mm dia, Turn buckle of length 356 mm. with 250 mm. long threaded adjustable 16 mm. dia. MS strain rod and thimble including supply & erection of 11 KV/LT guy insulator as per IS specification, hot dip (heavy duty) stranded wire of size 7/2.5 mm. grade - IV as per ISS:2141/1979 having minimum tensile strength 700N/mmsq. with Zinc coating (heavy type coating conforming to IS:4826/1979, fastened with stay clamps as required. ( including supply of MS clamp & Nuts & bolts as reqd) as per TSECL specification)
Stranded wire (7/2.5mm)
11kV stay insulator
LT stay insulator
Design, Engineering, testing, manufacturing, commissioning and Supply, of 1.1KV Class, 3-phase Areial Bunched cable of Size 3Cx25 sq mm +1x16 sq mm +1x25 sq mm at ESD-Kathalia store as per direction of Eng-In-Charge.
Design, Engineering, testing, manufacturing, commissioning and Supply of Straight line Suspension Assembly suitable for bare messenger wire of size 35 to 95sq.mm on existing pole ,galvanised clamp with MS Clamp and nut & bolts for LT AB Cable.
Design, Engineering, testing, manufacturing, commissioning and Supply of Dead End / anchoring assembly comprising of tension bracket wedge type tension clamp , flexible stainless steel ropr for fixing of tension clamp to bracket (suitable for 30 to 70 sq mm bare messenger).
Design, Engineering, testing, manufacturing, commissioning and Supply, of 'Eye Hook' (Suitable for all size cable)
Design, Engineering, testing, manufacturing, commissioning and Supply of LT Insulation Piercing Connectors (IPC) for making Tee/Tap-off/Service connectors to an ABC/Bare Overhead Line suitable for 25sqmm to 95sqmm
Design, Engineering, testing, manufacturing , commissioning and Supply, of Anchoring Clamp assembly for insulated neutral cum Messenger wire.
Design, Engineering, testing, manufacturing , commissioning and Supply, of Pole clamp assembly for insulated neutral cum Messenger wire.
Design, Engineering, testing, manufacturing, commissioning and Supply, of Pole mounted 3-Phase, 400Amp weather proof multi connection LT SERVICE MAIN DISTRIBUTION BOXES
Design, Engineering, testing, manufacturing , commissioning and Supply, of Pole mounted 1-Phase, 200Amps weather proof multi connection LT SERVICE MAIN DISTRIBUTION BOXES
Supply of Earth Spike unit, the item include 20 mm dia, 1.8 mtr long GI Earth Rod including connecting clamps , bolts etc. as required and excavation of earth, refilling ramming etc.
Supply of 2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required as per direction of Engineer-in-charge.( including supply of MS clamp, Nuts & bolts as reqd)
Supply of 2.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole including supply of i) 2(two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Supply of 3.1 mtr. long 65 X 65 X 6 mm. MS angle sub-station bracket along with drilling of holes as required for using as G.O.S Handle support and fixing including supply with (i) 2(two) nos. clamps of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Supply of 0.8 mtr. long 100 X 50 X 50 mm. MS channel cross arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. clamp of 50x6 mm. MS flat, nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Supply of 1.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on single steel tubular pole or PCC pole or RS joist including supply with (i)1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Supply 1.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge. ( including supply of MS clamp & Nuts & bolts as reqd)
Supply of 11 KV Pin Insulator with GI Pin complete as per the direction of the engineer In- Charge
Supply of 11 KV Disc Insulator with fittings,nuts & bolts,washers etc. as required complete as per the direction of the engineer In- Charge
Supply of triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.
Supply of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air break switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of nuts and bolts as required.
Supply of 9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Nominal Creepage distance 300mm. conforming to ISS:3070/1985.
Supply of of AI. wound three Phase 50 Hz AC, out door type 11/0.433KV, distribution transformer complete with necessary accessories and Transformer oil conforming to relevant ISS and Including supply of 2 ( two ) Nos strain Screw and nuts & bolts as reqd. as per the direction of Engineer-in-charge and approved drawing:- a) 100 KVA.
Supply of ACSR conductor 6/1/2.59 mm dia.
Supply of Stay Clamp by 50x6 mm MS Flat i/c holes.
Supply of Bracket Clamp by 50x6 mm MS Flat i/c holes.
LT schackle insulator 3x3.5
LT streaps with nuts & bolts
120 mmsq PVC cable
Nuts & bolts (Assorted size)
100 Amp cut out
ERECTION
Erection of PCC pole direct in earth including excavation, refilling and ramming etc. as required (1/6 th length of pole to be embedded in Earth as required as per the instruction of Engg. In-charge:- a) 9 mtr. Long, working load 250Kg.
b) 8 mtr. Long, working load 200Kg.
Eerection of 11 KV/LT painted stay set complete direct in earth with 16mm. dia. 1.8 mtr. long painted stay rod, one side formed an eye and welded with internal dia 40 mm with one thimble and other side of the rod each threaded and fitted with 2 nos. of suitable hexagonal nuts and with one round MS washer of size 40 X 40 X 2 mm complete with MS Anchor plate of size 300 X 300 X 8 mm, dimension with centre hole of 18 mm dia, Turn buckle of length 356 mm. with 250 mm. long threaded adjustable 16 mm. dia. MS strain rod and thimble including supply & erection of 11 KV/LT guy insulator as per IS specification, hot dip (heavy duty) stranded wire of size 7/2.5 mm. grade - IV as per ISS:2141/1979 having minimum tensile strength 700N/mmsq. with Zinc coating (heavy type coating conforming to IS:4826/1979, fastened with stay clamps as required. ( including supply of MS clamp & Nuts & bolts as reqd) as per TSECL specification)
Erection, Laying hoisting & drawing of 1.1KV Class, 3-phase Areial Bunched cable of Size 3Cx25 sq mm +1x16 sq mm +1x25 sq mm
Erection, Laying hoisting & drawing of 1.1KV Class, 1-Phase Areial Bunched cable of Size 3Cx25 sq mm +1x16 sq mm +1x25 sq mm where practically 5km , 5wire LT AB cable need to separate and make it to 5KMx5Nos LT AB cable=25KM. only Single phase 65KM and neutral to be run as existing bare conductor to replaced ACSR bare conductors ( Only phases to be replaced by LT AB Cable)
Erection & fitting fixing of Straight line Suspension Assembly suitable for bare messenger wire of size 35 to 95sq.mm on existing pole ,galvanised clamp with MS Clamp and nut & bolts for LT AB Cable.
Erection and fitting fixing of Dead End / anchoring assembly comprising of tension bracket wedge type tension clamp , flexible stainless steel ropr for fixing of tension clamp to bracket (suitable for 30 to 70 sq mm bare messenger).
Erection and fitting fixing of 'Eye Hook' (Suitable for all size cable)
Erection of LT Insulation Piercing Connectors (IPC) for making Tee/Tap-off/Service connectors to an ABC/Bare Overhead Line suitable for 25sqmm to 95sqmm
Erection of Anchoring Clamp assembly for insulated neutral cum Messenger wire.
Eerection of Pole clamp assembly for insulated neutral cum Messenger wire.
Erection of Pole mounted 3-Phase, 400Amp weather proof multi connection LT SERVICE MAIN DISTRIBUTION BOXES
Erection of Pole mounted 1-Phase, 200Amps weather proof multi connection LT SERVICE MAIN DISTRIBUTION BOXES
Installation of Earth Spike unit, the item include 20 mm dia, 1.8 mtr long GI Earth Rod including connecting clamps , bolts etc. as required and excavation of earth, refilling ramming etc.
Erection of 2.8 mtr. long 100 X 50 X 50 X 6 mm. MS channel sub-station bracket including drilling of holes as required for Transformer support and fixing including supply with (i) 2 (two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required as per direction of Engineer-in-charge.( including supply of MS clamp, Nuts & bolts as reqd)
Erection of 2.8 mtr. long 75X40X40X6 mm. MS channel bracket for G.O.S & D.O. fuse unit on double steel tubular pole or PCC pole including supply of i) 2(two) nos. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Erection of 3.1 mtr. long 65 X 65 X 6 mm. MS angle sub-station bracket along with drilling of holes as required for using as G.O.S Handle support and fixing including supply with (i) 2(two) nos. clamps of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Erection of 0.8 mtr. long 100 X 50 X 50 mm. MS channel cross arm on steel tubular pole or PCC pole or RS joist with 1 (one) no. clamp of 50x6 mm. MS flat, nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Erection of 1.2 mtr. long 75 X 40 X 40 X 6 mm. MS channel cross arm on single steel tubular pole or PCC pole or RS joist including supply with (i)1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge.( including supply of MS clamp & Nuts & bolts as reqd)
Erection 1.5 mtr. long 65 X 65 X 6 mm. MS angle guard cross arm on Single steel tubular pole or PCC pole or RS joist including supply with (i) 1 (one) no. clamp of 50x6 mm. MS flat, (ii) nuts and bolts as required and as per direction of Engineer-in-charge. ( including supply of MS clamp & Nuts & bolts as reqd)
Erection of 11 KV Pin Insulator with GI Pin complete as per the direction of the engineer In- Charge
Erection of 11 KV Disc Insulator with fittings,nuts & bolts,washers etc. as required complete as per the direction of the engineer In- Charge
Erection of triple pole (3 phase), 12 KV, 200 Amp. drop out fuse unit for operation in 11 KV, 50 Hz, AC system as per relevant IS specification along with Supply of nuts & bolts and bimetallic lugs for necessary connection with the transformer HT bushing by ACSR.
Erection of triple pole (3 phase), 12 KV, 200 Amp. Manually gang operated, air break switch, 3 post vertical type single brake, complete with post insulator for operation in 11 KV, 50 Hz, AC system as per relevant IS specification with supply of nuts and bolts as required.
Erection of 9 KV, 5 KA single pole metal oxide gapless surge type LA suitable for nominal system voltage of 11 KV, 3 phase, 50 Hz, AC supply. Nominal Creepage distance 300mm. conforming to ISS:3070/1985.
Commissioning of AI. wound three Phase 50 Hz AC, out door type 11/0.433KV, distribution transformer complete with necessary accessories and Transformer oil conforming to relevant ISS and required connection by ACSR from 11 KV line to Transformer via G.O.S & D.O.F (Including supply of 2 ( two ) Nos strain Screw and nuts & bolts as reqd. as per the direction of Engineer-in-charge and approved drawing:- a) 100KVA
Stringing of ACSR (6/1/2.59 mm dia) conductor in/c laying, hoisting, binding, jumpering etc. as required as per direction of Engineer-in-charge
LT schackle insulator with streaps nuts & bolts
Supply and erection of earthing set as per ISS : 3043 of 1966 and with upto date amendment having 2.5 mtr long G.I. pipe (ISI marked) of 40 mm diameter with necessary fabrication,salt & charcoal,lugs,polythene pipe, including a pair of clamps of 50 X 6 mm M.S. flat & 12 mm dia galvanized nuts & bolts,connecting materials i/c excavation, re-filling with alternate layers of salt & charcoal and providing connection of earthing materials and equipments to earth electrode as per REC specification & approved design & drawing of TSECL .
Fixing of LT cut-out with necessary cable connection i/c supply of wooden plank etc as required. (as per the direction of Engineer-in-charge)
CARRYING
Carriage of line materials such as ACSR, G.I wire, Standard wire, earthing materials, cross arms, stay set etc. by mechanical transport, handcart & manual labour from store yard ESD- Kathalia to work site i/c loading, un-loading and stacking etc as required as per direction of Engineer-in-charge.
Carriage of line line materials such as Pin Insulator, Disc Insulator, GOS,DOF,LA, Shackel Insulator etc. by mechanical transport, handcart & manual labour from store yardESD- Kathalia to work site i/c loading, un-loading and stacking etc as required as per direction of Engineer-in-charge.
Carriage of PCC Poles by mechanical transport, handcart & manual labour from store yard ESD- Kathalia to work site i/c loading, un-loading and stacking etc as required as per direction of Engineer-in-charge.
M/s Bhattacharjee Construction
BALARAM DAS
ADHIR DEBNATH
KAJAL DAS
Basant Cables And Conductors Pvt. Ltd.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .