| Sl No | Description | Qty | Unit | BK CONSTRUCTION L2 | M/S K K ENTERPRISES L3 | M/S SURJIT CONSTRUCTION COMPANY L4 | Shree Saaram Engineers L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Supply and Installating VCB ,11 KV ,3 phase,50Hz,outdoor type ,rupturing capacity 250 MVA of rating 400 Amps ,Horizontal draw out type 26.03 KA for 3 sec with spring charging motor of 230 V AC ,tripping coil suitable for 110DC-01 Unit , current transformer 200/1A,CL 0.5/5P20,10 VA for each core,Cast Resin type -03 Nos ,Relay - Feeder protection -(3O/C+1E/F-IDMT+Inst) with RS 485 - Make : L&T ,Trip circuit supervise relay, Make : L&T ,Master trip relay - C&S ,Aux Relay for transformer protection _ C&S - complete set of 1 ,Meters - Digital voltmeter - 01 (L&T) ,Digital Ammeter - 01(L&T), Digital Multifunction Meter -01 (L&T) ,Miscellaneous items -Power Pack 230 V AC/110 V DC -01, 12 way annuciator - 01 No ,Hooter for alarm -01 No,Fuses/MCBs, Panel illumination lamp-01 No ,Plug and socket -01 No,L/R switch -01 No, TNC switch - 01 No,Thermostate - 01 No, Panel space for heater assembly - 01 No,Emergency push button -01 No,Indicating lamps-08 Nos. | 4 | Job | 7,61,000 ₹30,44,000 | 8,45,000 ₹33,80,000 | 8,20,000 ₹32,80,000 | 7,11,540 ₹28,46,160 Lowest |
| 2.00 | M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge. | 8 | Each Set | 8,500 ₹68,000 | 6,500 ₹52,000 Lowest | 10,500 ₹84,000 | 6,500 ₹52,000 Lowest |
| 3.00 | Construction of Plinth of size 2.0 mx 2.0 mx1.5 m for VCB, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified, directed by the Engineer-in-charge and as shown on TD drawing No CEPZ/98/TD/6, Sheet No 2/2. | 4 | Each Job | 55,000 ₹2,20,000 | 45,000 ₹1,80,000 Lowest | 85,000 ₹3,40,000 | 1,07,380 ₹4,29,520 |
| 4.00 | M & L for cable jointing kit for 11 kV grade (Earthed) HT cable for Outdoor termination Cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable complete all as specified and directed by EIC. | 8 | Each | 12,500 ₹1,00,000 | 9,500 ₹76,000 | 15,000 ₹1,20,000 | 3,500 ₹28,000 Lowest |
| 5.00 | M & L cable jointing kit for 11 kV grade (Earthed) HT cable straight through joint Cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable complete all as specified and directed by EIC. | 4 | Each | 18,500 ₹74,000 | 12,500 ₹50,000 | 15,000 ₹60,000 | 7,500 ₹30,000 Lowest |
| 6.00 | Supply, laying, commissioning and testing in repairs of XLPE insulated, seceened, PVC bedded, galvanised steel wire armoured heavy duty electric power cable with aluminium conductor, 6.35/11 KV suitable for 11000 volts grade, cross-sectional area 95 sqmm 3 core complete all as specified and directed. | 130 | RM | 1,450 ₹1,88,500 | 1,350 ₹1,75,500 | 850 ₹1,10,500 Lowest | 1,472.64 ₹1,91,443.2 |
| 7.00 | Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
Note: (i) During the excavation damage of Road, Electric cable,Signal cable and Sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface.
(ii) Excavation of Hard surface are included in same item ,NO extra charge will be paid. | 24.57 | CUM | 240 ₹5,896.8 | 180 ₹4,422.6 Lowest | 650 ₹15,970.5 | 280 ₹6,879.6 |
| 8.00 | Returning, filling in including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. Complete all as specified and directed. | 14 | CUM | 120 ₹1,680 | 150 ₹2,100 | 200 ₹2,800 | 50 ₹700 Lowest |
| 9.00 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. | 10.57 | CUM | 140 ₹1,479.8 | 120 ₹1,268.4 | 200 ₹2,114 | 50 ₹528.5 Lowest |
| 10.00 | M & L for sand cushioning for under ground cable with locally available clean sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed.
(Note-Punned thickness ie 18 mm will be measured and paid) | 7.37 | CUM | 1,450 ₹10,686.5 | 1,685 ₹12,418.45 | 1,850 ₹13,634.5 | 950 ₹7,001.5 Lowest |
Tender Value
₹38.8 L
EMD Value
₹77,600
Closing Date
15 Jul 2026, 6:00 pmClosed
CWE Nagpur
Commander Works Engineer Bldg No. P-9, Sitabuldi Fort, Nagpur - 440 001 Pin-900419, C/o 56 APO
PROVN OF HT CIRCUIT BREAKER FRO INCOMING 11KV FEEDER AT VARIOUS LOCATION AT STN HQ BARODA UNDER GE (ARMY) BARODA
2026_MES_771852_1
85052/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Army) Baroda
As per tender documents
9 documents required · 9 mandatory
₹500
GE (Army) Baroda
₹77,600
Yes
23 Jul 2026
12 Jun 2026
18 Jul 2026
12 Jun 2026
15 Jul 2026
26 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and Installating VCB ,11 KV ,3 phase,50Hz,outdoor type ,rupturing capacity 250 MVA of rating 400 Amps ,Horizontal draw out type 26.03 KA for 3 sec with spring charging motor of 230 V AC ,tripping coil suitable for 110DC-01 Unit , current transformer 200/1A,CL 0.5/5P20,10 VA for each core,Cast Resin type -03 Nos ,Relay - Feeder protection -(3O/C+1E/F-IDMT+Inst) with RS 485 - Make : L&T ,Trip circuit supervise relay, Make : L&T ,Master trip relay - C&S ,Aux Relay for transformer protection _ C&S - complete set of 1 ,Meters - Digital voltmeter - 01 (L&T) ,Digital Ammeter - 01(L&T), Digital Multifunction Meter -01 (L&T) ,Miscellaneous items -Power Pack 230 V AC/110 V DC -01, 12 way annuciator - 01 No ,Hooter for alarm -01 No,Fuses/MCBs, Panel illumination lamp-01 No ,Plug and socket -01 No,L/R switch -01 No, TNC switch - 01 No,Thermostate - 01 No, Panel space for heater assembly - 01 No,Emergency push button -01 No,Indicating lamps-08 Nos. | 4 | Job | - | - |
| 2 | M&L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried dirctly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI strip 32x6mm by means of bolts. nuts,check nuts and washers etc including protection pipe 15mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation in disintergratedand hard soil and 20mm dia GI pipe with funel for watering PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engr -in -Charge. | 8 | Each Set | - | - |
| 3 | Construction of Plinth of size 2.0 mx 2.0 mx1.5 m for VCB, using 100 mm thick PCC 1:4:8 type D-2 as in lean concrete, flyash brick masonry in CM 1:6, the top of the plinth shall consist of 100 mm thick PCC 1:2:4 type B-1 (using 20 mm graded stone aggregates) over 75 mm thick PCC 1:4:8 type D-2 over compacted moorum filling, 10 mm thick rendering in CM 1:4 on brick surface with and including 25 cm thick stone aggregates of size 12.5 mm all around upto and including 1.5 m from the edge of the plinth including the RCC Gate and fencing with angle iron post in lieu of RCC post complete all as specified, directed by the Engineer-in-charge and as shown on TD drawing No CEPZ/98/TD/6, Sheet No 2/2. | 4 | Each Job | - | - |
| 4 | M & L for cable jointing kit for 11 kV grade (Earthed) HT cable for Outdoor termination Cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable complete all as specified and directed by EIC. | 8 | Each | - | - |
| 5 | M & L cable jointing kit for 11 kV grade (Earthed) HT cable straight through joint Cold shrinkable type complete with jointing material and accessories suitable for 3 core x 95 Sqmm XLPE armoured aluminium conductor cable complete all as specified and directed by EIC. | 4 | Each | - | - |
| 6 | Supply, laying, commissioning and testing in repairs of XLPE insulated, seceened, PVC bedded, galvanised steel wire armoured heavy duty electric power cable with aluminium conductor, 6.35/11 KV suitable for 11000 volts grade, cross-sectional area 95 sqmm 3 core complete all as specified and directed. | 130 | RM | - | - |
| 7 | Excavating in trenches not exc. 1.5m wide and not exc. 1.5 metre deep and getting out in soft/loose soil complete all as specified and directed.
Note: (i) During the excavation damage of Road, Electric cable,Signal cable and Sewage line should be repaired by the contractor without any extra coast and surface should be matched as existing surface.
(ii) Excavation of Hard surface are included in same item ,NO extra charge will be paid. | - | CUM | - | - |
| 8 | Returning, filling in including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. Complete all as specified and directed. | 14 | CUM | - | - |
| 9 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. | - | CUM | - | - |
| 10 | M & L for sand cushioning for under ground cable with locally available clean sand for protection of cable 8cm before laying cable and 15cm deep over the cable including spreading and onsolidations, complete all as specified and directed.
(Note-Punned thickness ie 18 mm will be measured and paid) | - | CUM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
BOQ_864305.xls
BOQ • 0.63 MB
Tender.pdf
Tender Documents • 0.86 MB
corrigendum1.pdf
PDF • 2.65 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .