Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹29.2 L Quoted ₹29.5 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹30.3 L+₹74,752.50 (2.53%)Rejected-Finance | ₹30.3 L+₹74,752.50 (2.53%) | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹33.4 L+₹3.8 L (12.9%)Rejected-Finance PARTH B 203 PATEL COLONY STREET NO 11 ROAD NO 3 JAMNAGAR 361 006 GUJARAT | JAMNAGAR | GUJARAT | 361006 | ₹33.4 L+₹3.8 L (12.9%) | L3 | Rejected-Finance Not being L1 |
Tender Value
₹26.7 L
EMD Value
₹53,400
Closing Date
7 Dec 2021, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
ADDITION/ ALTERATION AND IMPROVEMENT TO BLDG No. P-105 AND AUGMENTATION OF TOILET BLOCK FACILITIES FOR BLDG No. P-341 AT INS VALSURA, JAMNAGAR
2021_MES_479861_3
8557
Open Tender
Civil Works - Others
Item Rate
180 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹53,400
Yes
13 Aug 2022
25 Nov 2021
9 Dec 2021
25 Nov 2021
7 Dec 2021
25 Nov 2021
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed.
Dismantling floor, hearth or wall tiling inluding cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MD land complete all as directed.
Taking down chowkats or frames exc 1.5 sqm but not exc. 4.0 Sqm each with shutters (without taking off shutters from frame) and stacking at site where directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, laying of pipe line etc and getting out in any type of soil (i.e.soft/ loose or hard/ dense soil) complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
Removing excavated surplus soil to a distance exceeding 50 mts and not exceeding 250 mts and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as directed.
M & L for Moorum / red bajri filling under floors or in foundation etc including spreading levelling , watering and well ramming in layers not exc . 15 cm thick complete all as specified and directed.(Note i): Moorum brought from out side MD land . ii) Measurements shall be taken after compaction).
M&L broken stone or boulders hardcore of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L for PCC 1:4:8, type D2 (using 40 mm graded granite stone aggregate) as in foundations, filling and mass concrete for steel pole complete all as specified.
M&L for PCC 1:2:4, type B1 (using 20 mm graded granite stone aggregate) as in coping including necessary formwork complete all as specified.
M&L for plain cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregate as in cast in situ in cills and other similar bands, plinth courses, coping, bed plates including necessary form work, weathering slightly rounded, chamfered angles and throating complete all as specified and directed.
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
M&L factory made pre cast PCC 1:3:6 type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks or slabs, 10 cm thick (plain or interlocking joints) and setting in CM 1:4 complete all as specified.
M&L RCC M-30 ( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, canopies, deck slab etc complete all as directed. .Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in chajja complete all as directed. Note: Reinforcement shall be measured and paid separately.
M&L RCC M-30 (using 20 mm graded granite stone aggregate) as in beams, cantilevers, bressummers lintels over 1.5m span complete all as directed.. Note: Reinforcement shall be measured and paid separately.
Cutting holes in brick works of size not exc half brick built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required including making good as per its original specification with out any extra cost complete all as directed.
Cutting chases in brick/ stone wall, pinning in, making good to facing where required and plastering in CM 1:4 to ends of edges of landing, steps, cills, lintels etc and cutting chases not exceeding 10 cm girth for concealed water tubing and making good cutting as per its original specfication complete all as directed.
Supply only liquid water proofing coumpound.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved.
M&L for Extra for forming fair finishing drain or channel 15 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitered stopped ends etc complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (Horizontal or sloping), flat rough finished surface all as specified.
Formwork to chullah hoods, chajjas, troughs and similar items including edges, flat rough finished surface all as specified.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat rough finished surface all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs exc 10cm but n exc 20cm thick slab for flat rough finished surface all as specified.
S&F Second class hard wood factory made kiln - seasoned, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints and fixed in position complete all as directed.
S&F 35 mm thick flush shutter with solid core construction with block board core and plywood face panels, commercial type on both sides including exposed surfaces finished with external teak wood lipping, 6mm thick fixed with nails and both side 0.90mm thick Decorative laminate type 1 of surface finish, colour and pattern and approved, fixed with approved adhesive as per manufacture's instructions complete all as directed.
S&F fibre glass reinforced plastic (FRP) door frames of three legged of cross section 90x45 mm having single rebate 32x15 mm to receive shutter of 30 mm thickness. The laminate door frame moulded with fire retardant grade unsaturated polyster resin and chopped mat. Door frame laminate of 2 mm thick and filled with suitable wooden block in all three legs. The frame shall be covered with fibre glass from all sides. Mild steel stay shall be provided at the bottom to steady the frame.
S&F 30 mm thick fibre glass reinforced plastic (FRP) paneled door shutter made with fire retardant grade unsaturated polyester resin moulded to 3 mm thick FRP laminated for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5 mm thick FRP laminated for panels.
S&F in repairs door closer aluminium (extruded section body), hydraulically regulated, designation No.3 universal type, suitale for door shutters of 851 to 1000 mm in width and weight between 61 to 80 kg and fixed complete all as directed..
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc. complete all as directed.
S&F anodised aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutter, side hung type without sash bar, aluminium section weighting 0.55 kg/m including necessary jointing cleats, louvers, glazing clips, rubber packing anodized aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (2 Nos.) etc. complete all as directed. Note: Glass shall be measured and paid seperately.
S & F 200 mm long brass, barrel tower bolt (ISI marked) with cast or sheet barrel and rolled or cast bolts and fixed.
S&F 100 mm size butt hinges, medium weight extruded aluminium alloy with galvanised mild steel hinges pin anodised and fixed type C-21.
S&F 100 mm size butt hinges stainless steel (ISI Marked), medium weight approved.
S&F 150 mm size aluminium alloy handles (ISI Marked) fabricated type anodised and fixed.
S&F 150 mm size brass handles (ISI Marked), cast type, polished bright.
S&F 300 mm long aluminium alloy, anodised sliding door bolt (ISI Marked) with hasp, staple (bolt type) and fixing clip of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed.
S&F 300 mm long brass, sliding door bolt (ISI Marked) with sand or die cast brass hasp, staple (bolt type) and fixing bolts with rolled of drawn bolt and fixed.
S&F 140 mm size (overall length of cover plate) floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as directed.
S&F mild steel hold fasts of flats iron 25x5mm confirming to Fe 410-O or Fe 310-O and similar items.
S&F Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as directed.
S & F 10 mm dia and over TMT bars cut to length bent to shape required cranking including bending , hooking ends etc and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No. 45 here-in-above but 8mm dia bar - do -
All as per item No. 45 here- in – above but 5 mm dia and over upto 10 mm dia as in stirrups
M&L framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
Dismantling of any type of ceiling boards after electrically disconnection and taking down electrial fittings & fixtures including wiring stacking at site and S&F new 12mm thick mineral fibre board fixed or laid/ inserted to GI powder coated frame work with screws fixed to false ceiling with and including GI powder coated snap Grid 605 x 605 mm frame work using 25mm x 35mm x 0.7mm main Tee runner to be interlocked, 25mm x 35mm x 0.75mm cross Tee and 25x35x0.70mm angles fixed to wall for ceiling including necessary supporting hanger with 4 mm dia GI (upto 2.5m long adjustable) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 25x7mm size 60mm long for securing frame work to ceiling suspended at 120cm etc. both way (Size of grid shall be 605mm x 605mm) including 8mm thick decorative acoustic mineral fibre baord as described fixing with clips etc. and ceiling baord fixed as per manufacturerrs instructions and finally fixing the taken down fittings & fixtures & wiring to its orginal postion are different locations including testing on completion as ordered complete alll as directed. (Note:(i) The quoted rate is deemed to be incluvise of mineral fibre board, aluminium snap grid, susupenders complete (ii) Quoted rate shall be inclusive of taking down existing E&M fittings and wiring in ceiling if any and re-fixing the same in position, after completion of ceiling work without any extra cost to Govt.)
M&L for 25mm avg thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) for levelling the undulated floor after dismantling complete all as directed.
M & L for 75 mm thick plain cement conctere 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in plinth protection/ path etc. finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8, type D2 (using 40 mm graded crushed granite stone aggregate) as in sub base, floors, pavings etc. finished fair and even complete all as specified.
M & L non-skid coloured ceramic tiles 400x400x7 to 8 mm thick (square/ rectangular), in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified.
M&L glazed ceramic designer tiles any shade or pattern as approved of size 600x300x7 mm thick, on verticals surfaces, set and jointed in neat cement slurry including 10 mm thick back coat in CM 1:4 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all directed.
M&L double charged/ ultra charged vitrified ceramic tiles in dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. tiles laid over and including 15 mm thick screed bed in cement mortar 1 :6 set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed in floor and wall surfaces complete all directed.
M&L double charged/ ultra charged vitrified ceramic tiles in light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm in floors etc. tiles laid over and including 15 mm thick screed bed in cement mortar 1 :6 set and jointed in neat cement slurry and pointed in white or coloured cement to match fixed in floor and wall surfaces complete all directed. (Note for item No 53 to 56 : i) Quoted rate is deemed to be inclusive of cement screed/ back coat. ii) Colour of tiles shall be got appproved before incorporation in the work)
M&L 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin counter and like set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified.
M&L 20 mm thick granite slab (of any type) work (table rubbed, polished and rounding of edges where ever necessary as ordered) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone laid over and including 15 mm thick screed bed in cement mortar 1:6 complete all directed and specified. (Note: Quoted rate is deemed to be inclusive of rounding of edges and Screed bed)
M&L 20 mm thick granite slab (of any type) work (table rubbed, polished and rounding of edges where ever necessary as ordered) bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone, as in verticle surface and including 10 mm thick back coat in cement mortar 1:4 complete all directed and specified. (Note: Quoted rate is deemed to be inclusive of rounding of edges and back coat)
Rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations complete all as directed.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work/ stone work or concrete surfaces mixed with WPC as per manufacturer instruction, and finished the surface fair and even complete all as specified and directed. (Note : WPC measured and paid separately).
M&L for rendering 15 mm thick in CM 1:6 on block masonry surfaces other than fair faces of brick work finished even and smooth without using extra cement complete all as specified.
M&L for rendering 10 mm thick in CM 1:6 on Brick/ block masonry surfaces other than fair faces of brick work finished even and smooth without using extra cement complete all as specified.
M&L for rendering 5 mm thick in CM 1:3 on fair faces of brick work or concrete surfaces on ceiling finished even and smooth without using extra cement complete all as specified.
M&L for forming external or internal rounded angles, exc 80mm but not exc. 200mm girth (over 200mm girth to be measured as circular work) complete all as specified and as directed.
Raking out joints/ pointing in cement mortar or random rubble or polygonal rubble uncoused or brought up o coarses and raised pointing in CM 1:3 to random or polygonal rubble, uncoursed or brought upto courses.
Three coats of white wash on newly plastered wall surface after necessary preparation of surface complete all as directed.
Three coats of white wash on newly plastered surface of ceiling after necessary preparation of surface complete all as directed.
M&L for preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or unplastered surfaces) and applying two coat of white wash of white wash complete all as directed.
M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over a coat of alkali resistant primer over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L for complete removal of existing treatment and preparing old plastered or unplastered surfaces of wall and applying two coats of oil bound distemper over a coaat of alkali primer over a coat of 1 mm thick white cement based wall care putty complete all as specified.
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as directed.
S&F 4.8mm thick tinted sheet glass, ordinary quality and glazing fixed to aluminium sections in square not exceeding 0.5 Sqm in each pane complete all as directed.
S&F 3 mm thick figured glass, ordinary quality and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane complete all as directed.
M&L for 15 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors in repairs complete all as directed.
M&L for 20 mm bore steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as directed.
S&F gun-metal globe or gate valves with iron wheel head screwed box and both ends for iron pipe for 20 mm bore of pipe or union complete all as directed.
S&F 15 mm bore bib taps long nose with wall flange, fancy type, cast copper alloy, chromium plated, long shank screwed for iron pipe or for brass ferrule complete all as directed.
S&F two way bib taps with health faucet with 1.2m brass flexible tube of length as ordered and wall hook mounted type chromium plated for EWC.
S&F 15 mm bore pillar taps, chromium plated brass with aerator, long shank screwed and fly-nuts, screwed for iron pipe or for brass ferrule complete all as directed.
S&F 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed.
S&F 550 mm x 400 mm size ( white) flat back, oval type vitreous china wash hand basin including cutting for and pinning ends of brackets or erecting stand, waste coupling & waste pipe complete all as directed.
S&F vitreous China squatting pan 'Orissa' pattern of size 580x440 mm white with integral foot rests water closet (Squatt pattern) including provision of lime concrete bedding with connecting to trap anti syphonage pipe etc. complete all as directed.
S&F vitreous China ware wash down water closet pan (Pedestal Pattern) (Kids EWC), lower height for children white with fixing bolt to floor and connecting pan to trap, pedestral pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe (excluding flushing cistern, flush pipe) complete all as directed.
S&F plastic water closet seat, white, closed pattern with flat bottom, cover and mild steel chromium plated or aluminised hinging device complete all as directed.
S&F 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified.
S&F PVC connection 15mm bore and 45cm long with two Nos of brass check nuts and washers complete all as directed.
S&F PVC waste pipe of suitable length for wash hand basin complete all as directed.
S&F 100 mm size PVC (SWR) multi floor trap with grating including jonting the same with solvent cement complete all as directed.
S&F soap dish, fixed to tiled walls with plugs and chromium plated brass screws complete.
S&F 100 mm bore spun pipe, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as directed.
All as per item No 92 here-in-above but fixed to walls -do-
S&F 75 mm bore spun pipe, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as directed.
All as per item No 94 here-in-above but fixed to walls -do-
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as directed.
All as per item No 96 here-in-above but 75 mm bore bends -do-
S&F 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) with oval acess door complete all as directed.
All as per item No 98 here-in-above but 75 mm bore bends -do-
S&F in repair 100 mm bore cast iron branch pieces, Y, tee, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval acess door complete all as directed.
All as per item No 100 here-in-above but 75 mm bore branch pieces -do-
S&F 100 mm bore cast iron branch vent cowl complete all as directed.
All as per item No 102 here -in -above but 75 mm bore branch pieces -do-
S&F 75 mm diameter of out let Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as directed.
S&F PVC (SWR) Gully trap 125/110 mm including jointing the same with solvent cement complete all as directed.
S&F 100mm dia P or S trap complete all as directed.
S&F 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover including brass float valve high pressure suitable for 20 mm bore of pipe with polythene float, fixture hoisted and fixed in position where ordered and making necessary connection and testing including dismantling existing PVC/RCC water tanks any capacity fixed in any description and stacking at site complete all as directed.
M&L for concrete bed in PCC 1:3:6 type C2 using 40 mm graded stone aggregrate to 150 mm bore SWG/ Hume pipe including packing and haunching completely surrondings of the pipe after they are laid and tested complete all as specified and directed.
M&L for Reinforced concrete pipe 150mm bore Class NP2 (ISI Marked ) alongwith collar laid to slope in trenches over PCC bed & jointed in cement mortar 1:3 and tested on completion complete all as specified and directed.
M&L for cutting into existing manhole for connecting 150 mm bore (internal dia ) new drain pipe, making good to pipe and rendering, cuttingout existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 using 20 mm graded granite stone aggregrate, smooth finished and reforming benching as required complete all as specified and directed.
Cutting/ Chipping the spalling concrete surface of column, beams, slabs, chajjas, cantilever etc trimming, cleaning the surface to receive guniting/ plastering all as specified and directed.
M&L for applying epoxy treatment with Nitobond AR of Fosroc chemical or equivalent of Dr. Fixit or equivalent for bonding old demolished concrete surfaces and guniting including application of on coat of Nitozinc primer to the exposed reinforcement wherever required complete all as specified and directed by Engr-in-charge.
M&L for providing pressure guniting averaging 20mm thick in CM 1:3 to soffits of slabs, chajjas/ parapets by applying chemical prior to gunniting including providing double scaffolding as required and removal of same after use complete all as specified and directed by Engr-in-charge.
E&M Items: Taking, down carefully copper/ aluminium point wiring (Light, Fan, socket or power) complete (fittings such as switches, celling roses, pendants, regulators, sockets, DB's) etc all as specified and directed.
Taking down carefully unserviceable Main switch and DB's including wooden board and removing from site including making good disturbed surfaces of wall all as complete as specified and as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC insulated unsheathed cable, copper conductor multistranded passing through heavy duty PVC casing, capping, double lock type, min 25 mm wide including sheet metal box, terminal plates suitable for modular switch, socket etc. with all accessories, concealed MS box / PVC modular box with cover and 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 116 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
M&L for point wiring with 1100 V, 1.5 Sqmm single core PVC FRLS insulated unsheathed cable, copper conductor multistranded passing through including PVC concealed conduit 20mm, concealed MS box/ PVC/ MS/ Cast Iron box and logic modular whtie plates of suitable as required at site with PVC insulated unsheathed stranded copper of size 1.5 sqmm earth copper cable, for one light point, bell point, fan point controlled by one switch including cutting and making good surface of walls applying suitable painting as required all as directed.
All as per item No. 118 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in same board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable complete all as directed.
All as per item No.118 here-in-above, but for 6 Amp (2/ 3 pin), modular switch socket in independent board with earth wire 1.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 118 here-in-above, but size of cable 2.5 Sq.mm for 16 Amp and 6 Amp (3 pin) combined, modular switch socket in independent board with earth wire 2.5 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
All as per item No. 118 here-in-above, but size of cable 4 Sq.mm for AC Metal socket in independent board with earth wire 4 Sq.mm PVC insulated multistranded copper conductor cable all as directed.
S&F Modular switch 1 way 6 Amps,1 module all as specified and direced.
S&F Modular switch 1 way 16 Amps,1 module all as specified and direced.
S&F Modular Socket 6A -2/3 pin combinaed 2 Module all as specified and directed.
S&F Modular Socket 16A -2/3 pin combinaed 2 Module all as specified and directed.
S&F Ceiling rose surface bakelite White/ Ivory/ Urea finish 50 mm dia three terminals including supply and fix PVC square mounting block complete all as specified and directed.
S&F TV socket out let 1 module. Make: Legrand Cat Part No. 6755 46 or equivalent in Havells/ L&T/ ABB
M&L For metal fluh boxes concealed for mounting concealed for mounting TV/ Telephone socket etc including logic modular plates and surrounds of suitable size complete all as directed. Make: Legrand Cat No. 6890 60 or equivalent in Havells/ L&T/ ABB
S&F Rigid non-metallic PVC conduit exclusive of boxes ( junction/ terminal) but inclusive all tees, bends, elbows, reducers and fixing accessories such as couplers lock nut saddles pipe hooks etc complete siz of 20mm.
S&F Step type electronic fan regulator modular type 120W, 2 Module
Taking down existing light fittings fixed in any description and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500 high quality design aluminium extruded with decortive and caps fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LGLZ01X020XC 20 W CCT 6500 or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
Taking down existing light fittings fixed in any description S&F new 42 W ultra slim, LED panel light fittings extrucded aluminium housing frame (Pendant) 1x4 ft. The CCT should be 3000 K including suspended accessories etc fixed as per manufacturers instructions and making necessary electrical connections and testing on completion complete all as directed. Make: Jaquar Cat No. LSVR03S042XW or equivalent of Bajaj / Crompton / Philips / Wipro/ Havells.
S&F Single pole sheet metal enclosure with a two pin and earth plug and socket complete 240V with one single pole MCB 20 amp all as specified and directed by Engr-in-Charge
S&F 1400 mm sweep, ceiling fan with all accessories 230 V, SP with provision of 3 core cable from ceiling rose to fan complete in fan hook including taking down old fan complete all as specified. Make: Bajaj Model No. Kessle 50 ISI 1400 mm White CF or equivalent in Havells/Khaitan/ Usha/ Orient) Note: Old ceiling fan shall be deposited in the AGE E/M store yard.
M&L for making arrangements for Fan hook of standard type as per SSR specification including cutting RCC slabs to the required depth upto existing MS bars tie up with new one and making good disturbed surfaces complete all as specified and as directed.
S&F sheet metal enclouser for DB'S in wall / Nitch when MCB's to be used Single pole and neutral, 8 way, Double door 240 Volt with 200 Amps rated Bus bar complete all as specified and directed.
S&F in repairs MCB TPN 63 Amp, 240 V, 50 Hz, AC supply. Make: Legrand Cat No. 4086 83 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SPN 32 Amp 240 V 50 Hz AC supply, 10 kA. Make: Legrand Cat No. 4086 17 or equivalent of Havells / L&T / ABB
S&F in repairs MCB SP 6 to 32 amp, 50 Hz, AC supply, 10 kA. Make: Legrand Cat No. 4085 92 to 4085 95 / Havells / L&T / ABB
M&L for submain wiring with two runs of single core 6 Sqmm PCV insulated unsheathed multi-stranded copper conductor cable drawing in and including PVC rigid medium grade conduit concealed of suitable size complete including provision of 6 Sq mm copper unsheathed cable PVC insulated as earthwire connected to earth doll inclusive of al tees, bends, elbows,reducers etc all as specified and directed. Note: 3 runs of 6 sqmm cable and one run of PVC concealed conduit shall be measured as one unit length.
S&F 6 mtr height hot dip galvanized steel pole hexagonal/ octagonal cross sections grade S355JO of diamensions top dia 70 mm, bottom dia 130 mm, sheet thickness 3 mm, base plate diamensions 200x200x12 mm, foundation bolt size 4 nos x 20 mm dia, pitch circle dia 200 mm, bolt length 600 mm, projected bolt length 100 mm, anchor plate thickness 3 mm with inbuilt compartment for mounting switch box, earthing etc covered with hinged door confirming to IS:2629 / BS EN ISO 1461 alongwith connections with MCB SP 6 A-1 No., MCB TP 32 A 10 kA-01 No., Neutral connector - 63 A Cap-01 No. complete all as specified and as directed. Make: Bajaj BOP-6030 or equivalent in Philips / Havells / Wipro. Note: Earth work and PCC foundation shall be measured separately
Supply, fix, test and commissioning new 90 Watt LED street light fittings, High Efficiency IP 66 protection, powder coated pressure die cast aluminium housing and clear injection moulded polycarbonate / toughened glass have multi chip on board LED and metal clad PCB. The minimum lumen output of he system shall be greater than 9000 lumens with minimum lumens per watt 101±3% and must maintain 70% of lumens output at 50000 bhrs, asymmetric fixing to and including 40mm dia GI tubing medium grade, 1.5 mtr long bent to shape as in bracket fixed with nut and bolts, clamps etc., including connection wiring with 2.5 sqmm, 3 core copper conductor cable complete all as directed. Make: Bajaj Cat No. BRTFG 90W LED / Havells Cat No. ENDURA CITY LINER NEO SL 90W LED 757 SASYBOTG / Jaquar Cat No. LSRT01S090XC/ Crompton / Schreder
S&F 150 W LED flood lighting fittings 230 V outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as directed. Make: Phillips/ Havells / Bajaj / Crompton / Schreder.
S&F 3 core, 2.5 sqmm PVC insulated sheathed multistranded flexible copper conductor cable drawn through existing conduit pipe from junction box to fitting complete all as directed. Make: Havells / Finolex / Polycab
S&F junction box made from SMC/FRP sheet readymade of size 300x200x100 mm having 100 A capacity including RYB and neutral with aluminum busbar with 4 way connector, MCB SP 6 Amp 10 kA 240 V - 01 No. fixed to pole/wall with MS clamp 25x5 mm and necessary painting to MS clamp complete all as directed.
Supply, laying, testing XLPE insulated screened, PVC innersheathed galvanised steel strip or wire, armoured, heavy duty LT UG electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 Sq.mm, 4 core complete all as directed.
Supply and lay 40 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/ cm2, laid in trenches as cable protection with all fittings complete all as specified.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, char coal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point, complete all as specified including testing on completion.
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire including taking down existing earth continuity conductor complete all as specified and as directed.
S&F 40 mm bore GI tubing light grade including necessary fittings such as bend, tee, elbow etc complete in laid in trenches/ fixed on walls complete all as directed.
M/s.Bhavin Electricals
M/s Balaji Enterprise
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .