| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC 38 30 92 SAI NAGAR MARRIPALEM VISAKHAPATNAM 530 018 | VISAKHAPATANAM | ANDHRA PRADESH | 530018 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹6.4 L+₹76,549 (13.5%)Rejected-Finance | L2 | Rejected-Finance being not L1 | |
| 3 | L3₹7.0 L+₹1.3 L (23.0%)Rejected-Finance | L3 | Rejected-Finance being not L1 |
Tender Value
₹7.9 L
EMD Value
₹15,800
Closing Date
28 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Nitesh K Singh, IDSE AEE AGE (I) R and D NSTL
AGE (I) R and D, NSTL Complex, Visakhapatnam 530027
8410 CERTAIN REPAIRS TO WATER SUPPLY DISTRUBTION SYSTEM INCLUDING REPLACEMENT OF PIPE LINES AND ALLIED WORKS UNDER AGE (I) RnD VISAKHAPATNAM
2022_MES_550371_1
AGE I R AND D NSTL VIZAG 8410
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
Visakhapatnam
Class E Category a(ii)
7 documents required · 7 mandatory
₹500
AGE I R and D NSTL Visakhapatnam
₹15,800
Yes
31 Jan 2023
7 Sept 2022
30 Sept 2022
7 Sept 2022
28 Sept 2022
14 Sept 2022
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation of pole or cable trenches etc and getting out in hard/dense soil complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and as directed by the Engineer-in-Charge.
Material and labour for GI water tubing of size 80 mm, medium grade, galvanized laid in trenches all required fittings of the following bore of sizes including removing UNSV pipe and fittings from site of workand taken as credit complete all as specified and as directed by the Engineer-in-Charge. (Make: JINDAL/PRAKASH/BANSAL) Note: The rate is inclusive of necessary scaffolding arrangement and other accessories for fixing of pipe lines at high raise Bldgs.
All as per item No.4 here in above but of size 50 mm bore all as directed.
All as per item No.4 here in above but of size 40 mm bore all as directed.
All as per item No.4 here in above but of size 25 mm bore all as directed.
All as per item No.4 here in above but of size 20 mm bore all as directed.
All as per item No.4 here in above but of size 15 mm bore all as directed.
Supply and fix gun metal globe and gate valves of size 50 mm dia with iron wheels head screwed both ends for iron pipes of following sizes including taking down old u/s gate valves as credit complete all as specified and as directed.
All as per item No.10 here in above but of size 40 mm diae all as directed.
All as per item No.10 here in above but of size 25 mm diae all as directed.
Supply only Chlorine test kit of range 0.1 PPM to 2 PPM digital type. Make: Rmco or equivalent
M & L for complete removal of worn out gland rope and supply and fixing of general purpose Gland rope of 15/ 20 mm dia along with corroded nuts and bolts all as specified and directed.
Supply and fixing of Power contactor coil/ shunt closing coil operatable at 110V DC / 230/415V AC supply suitable for NSX250F U800V for the motor operated Schnider Make 4 pole MCCB of capacity 200A complete all as specified and direceted. Make : Cat No. 33662 of Schneider.
Suply and fixing of CI Foot Valve of 150 mm dia flanged type/ existing as per site requirenment along with brass diaphragm connected gasket nut and bolts with washers complete by removing the old unserviceable one all as specified and direceted. Make: Audco/ Kirloskar / Advance
M&L for taking up old CI Foot valve of 150 mm dia flanged type/ existing as per site, cleaning and removing all the accumulated sediments from the valve including change the Flange and strainer with new one , fixing the foot valve, testing, complete all as specified and directed by the Engineer-in-charge.
All as per Item no 17 herein before but for 200 mm dia
M&L for taking up old CI pipe 80 to 150mm from the trenches, cleaning and removing all the accumulated sediments from the pipe,relaying and jointing the pipe and testing complete including lead joints all as directed by the Engineer-in-Charge. Note: Excavation and earth work will be measured and paid separately.
Supply & fix in repairs the following Thermal over load relay of capacity 3 to 5 amp MN2 Make: L&T/ SIMENS /SCHNEIDER
Supply & fix in repairs the following Thermal over load relay of capacity 9 to 15 amp MN2 Make: L&T/ SIMENS /SCHNEIDER
Supply & fix in repairs the following Thermal over load relay of capacity 45 to 75 amp MN2 Make: L&T/ SIMENS /SCHNEIDER
Supply and fix in replacement 3 pole power contactor of 40-45 A 2 No + 2 NC Aux contacts, Type ML-3 Make : L&T/Simens/Schneider
Supply and fix in replacement 3 pole power Contactor 70-100 Amps, Type MNX 70 Make : L&T/Simens/Schnider
Supply and fix in replacement 3 pole power Contactor 12-30 Amps Type MNX 12 Make : L&T/Simens/Schnider
Supply and fix in replacement 3 pole power Contactor 18-30 Amps MNX 18 Make : L&T/Simens/Schnider
Disconnecting/ dismantling (electrically & mechanically) 3 phase, 440 volts, 50 Hz electrical motor from the mono-block pump set of 50 HP capcity capacity and shifting to work shop, opening the motor end cover, taking out rotor, taking out burnt stator winding, cleaning the stator and rewinding the motor with appropriate gauge, weight and turns of super enameled copper wire using proper insulating material, varnishing with Class-I varnish, heating/ baking, reassembling the motor completely and brought back to site, fixing back duly coupled with the pump in proper alignment, connecting and testing complete all as specified. Note :- Insulation of winding shall be Class 'B' up to 7.5 HP and Class 'F' for 10 HP and above.
Disconnecting/ dismantling (mechanically) mono-block pump set from Motor of 50 HP capacity and shifting to work shop, opening the pump and replace the damage parts, the nuts and bolts with new and renewal of gland packing, including lathe work. Reassembling the pump completely and brought back to site, fixing back duly coupled with the motor in proper alignment, connecting and testing complete all as specified.
Supply only Calcium hypochlorite dry free flowing and free from lumps for water treatment in 45 Kg sealed containers with available chlorine 65% and stability 1/15 and Particle size 99.5% all as specified and directed.
Dismantling the sluice valve, of size 80 mm bore dia, cleaning & removing of rust, old rubber washers, grinding and refacing the rings for smooth operation, renewal of gland plate, gland packing, check nuts & refixing in same position using new nuts, bolts, rubber gaskets, testing & commissioning including applying two coats of synthetic enamel paint (Black) all as directed by Engineer-in-Charge.
All as per item No.30 above but of size 100 mm bore dia
All as per item No.30 above but of size 150 mm bore dia
All as per item No.30 above but of size 200 mm bore dia
All as per item No.30 above but of size 250 mm bore dia
Supply and fix sluice valve, Cast Iron double flanged of 200 mm dia as per IS, with gasket washers, nuts, bolts etc including taking down old UNSV and taken as credit complete all as specified and as directed. Make: Kirloskar/ Leader/ Advance
All as per Item no 35 herein before but for 150 mm dia
All as per Item no 35 herein before but for 100 mm dia
All as per Item no 35 herein before but for 80 mm dia
Material and labour for complete removal of damaged pipe line portion with out damaging further and supply and fixing of new mechanical joint of lenght not less than 300 mm along with gasket and clamps, nut and bolts of the 200mm Dia complete all as specified and directed.
All as per above 39 herein before but for 150 mm dia
Supplying and laying synthetic Rubber insulated mats 3 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
LAKSHMI SAI CONSTRUCTIONS
sagar infra
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .