| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.6 LAccepted-Finance | L1 | Accepted-Finance Lowest Quoted Rates | |
| 2 | L2₹2.7 L+₹4,219 (1.60%)Rejected-Finance RZ M 21 NAND BLOCK MAHAVIR ENCLAVE PALAM NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Highest Quoted Rates |
Tender Value
₹2.5 L
EMD Value
₹5,094
Closing Date
5 Jun 2023, 3:00 pmClosed
Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL, Electrical Division 1st Floor, Telephone Exchange Laxmi Road, Dehradun
Providing Electrical Installation and Fans and Computer points in the newly proposed office area at third floor at TE Patel Nagar Dehradun
2023_BSNL_155122_1
13/EE(E)/BSNL/ED/DDN/23-24
Open Tender
Electrical Works
Item Rate
30 days
Dehradun
Please refer tender documents
3 documents required · 3 mandatory
₹590
Accounts Officer (Cash) O/o PGMTD BSNL Dehradun
₹5,094
20 Jun 2023
24 May 2023
6 Jun 2023
24 May 2023
5 Jun 2023
24 May 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.
2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
4 x 2.5 sq. mm + 2 x 2.5 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
2 x 1.5 sq. mm
3 x 1.5 sq. mm
4 x 2.5 sq. mm
6 x 1.5 sq. mm
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
S/F of following size energy efficient Ceiling fan suitable for operation on 230 Volts ,single phase 50 Hz AC supply complete etc as reqd without regulator)Make -( Bajaj/Polar /USHA /crompton /havells /orient )
S/F of two module Stepped type electronic fan regulator on the existing modular plate switch box I/c connections but excluding modular plate etc. as required.
Shifting & ITC of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.( OLD FANS)
S/F of D/S type fan hook made of MS rod i/c fixing the same on ceiling with suitable 2 no Anchor fastner etc as required
Providing and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note:- More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored.)
SITC of 400 mm sweep oscillating type wall mounted fan with three speed control regulator having metalic body and metal blade ,1360 RPM speed suitable for working on 230 V 50 Hz single phase AC supply & i/c fixing on wall with suitable fastner , connection etc. complete as required (Crompton/ Bajaj/orient/ polar/Almonard/USHA)
Supplying and fixing 200 mm Sweep Fresh air fan with louvers made out of engineering plastic suitable for 230 V single phase supply i/c making connections, testing etc. complete as required. (Make:- Havells Ventilair DX 200 mm or similar superior make)
SITC of 1x18/20 Watt LED Batten luminare with polycarbonate Housing having efficency 100 lumes /watt complete suitable for work on 230 volt 50Hz AC supply in the existing T-5 M/O fitting by removing the old faulty T-5 tube/choke & side holder etc. i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya ).
SITC of 42 Watt LED recess mounting luminare with high brightness SMD LEDs size 2 ft X 2 ft suitable for mounting on false ceiling having efficency 100 lumes /watt complete suitable for work on 230 volt 50Hz AC supply i/c connection testing etc complete as required.(Make -Philips /crompton/Havells /Bajaj/Wipro/Surya ). Havells Model PLUTONEO2X2PLR42WLED857S or Similar Superior
S/F of 6 A ,Spike guard having 4 universal socket with single switch having fuse and on off switch complete with 1.5 meter power cord etc as reqd
S/F of 12 Modular polycarbonate surface Box with cover plcate having 04 nos 5A modular switch and 04 nos modular 5 A socket ,connection etc ( For computers )
S/F of 8 Modular polycarbonate surface Box with cover place having 02 nos 5A modular switch and 02 nos modular 5 A socket ,connection etc ( For computers )
Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required.
200 mm X 125 mm X 60 mm deep
Supplying and fixing following piano type switch/socket on the existing switch box/cover & switch box including connections etc. complete as required.
5/6A Switch
3 pin 5/6A Socket
15/16 amp switch
6 pin 15/16 amp socket outlet
3 mm thick phenolic laminated sheet
Ding Dong bell
Call bell Buzzer
Remote operated Bell
5 A Plug Top
15 A Plug Top
Bell push
S/F of 25 mm wide PVC cassing capping on wall /roof wit suitalbe screw etc as reqd.
Removing of Exising Elecrical Insallaion like MCB DB , old Wiring ,Elecrical fiing , Fire detection system below false floor and reinsallaion he same at New location as per site requirement
Installation, Testing & Commissioning of 1.5 TR inverter type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall behind indoor unit , laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.( GM & DGM Chamber )
Pdg and Fixing additional 1/4"&5/8" size or size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
S/F of 19 mm dia PVC Wire braded pipe for drain water of SPAC i/c fixing on wall surface with suitable MS shaddle etc.as te reqd.
Provision of Top up of R-22/R-32 /410 gas in existing all type Window A.C /Split A.C/ units, flushing, testing etc. as required.
Supplying and fixing DP sheet steel enclosure on surface/recess along with 25/32 A, 240 V “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following size of white colour flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd
3x2.5 sq mm
JAI SAI ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .