Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC | ₹1.6 Cr | L1 | Accepted-AOC L1 Bidder Agreement Executed |
| 2 | L2₹1.9 Cr+₹26.5 L (16.4%)Rejected-Finance | ₹1.9 Cr+₹26.5 L (16.4%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹1.9 Cr+₹26.9 L (16.6%)Rejected-Finance | ₹1.9 Cr+₹26.9 L (16.6%) | L3 | Rejected-Finance L3 Bidder |
Tender Value
₹2.0 Cr
EMD Value
₹1 L
Closing Date
17 Mar 2025, 3:00 pmClosed
Superintending Engineer
Kerala Water Authority, P.H Circle, Kochi-11
State Plan 2022 23 Augmentation of WSS to ParavoorMunicipality and Adjoing Panchayaths 63MLD WTP at Chowara Supply and Installation of HT VT motor pumpset having discharge 2736m3perhr and total head of 42m at RWPH and allied works General Civil Work
2025_KWA_744378_1
E-Tender No 53/2024-25/SE/PHC/CHN
Open Tender
Civil Works - Water Works
Item Rate
270 days
Chowara WTP
Please refer Tender documents.
7 documents required · 7 mandatory
₹9,758
₹1 L
27 Jun 2025
28 Feb 2025
18 Mar 2025
28 Feb 2025
17 Mar 2025
28 Feb 2025
Amount
Appendix A: Supply and Installation of HT VT motor pumpset having discharge 2736m3/hr and total head of 42m at RWPH
OD292125/2023-2024:Supply Erection Commissioning of ISI marked KWA approved -Single Stage model make water lubricated vertical turbine pump set with bronze impeller, stainless steel shaft supported by anti friction bearing, MS flanged column pipe assembly (maximum length (20m)and painted with zinc chromate primer and anti corrosive paint two coats.) with necessary non reversible ratchet arrangement, water cooling system for bearing assembly and all accessories conform to relevant IS codes. The pump set shall be coupled with motor specified below in new foundation. The pump shall confirm to the following specifications as given below: The pump shall suit the existing/new foundation of KBL co. Make BHR 70 M,-single stage pump set in PWPH/RWPH to act as standby set for existing four pump sets. PUMP:- Vertical Turbine type , Discharge -2736 m3/ Hour , Total head -42 M, Speed 960 RPM, Head rise to shut off - 70 m, NPSH required - 0.50 m, Direction of rotation - clock wise , Well depth - 20 M, Types of installation above floor, Bowl efficiency -90%, Minimum submergence of bowl-2500mm , No. of stages - 1,Liquid handled- Raw water, Temperature -45 degree Celsius, Pump type-vertical turbine non pull out, Solid size-3mm, Internal head loss-0.3m Impeller Details : impeller material - BR IS :318 Gr- LTB-2, Impeller diameter minimum size - 620 mm , Impeller diameter maximum size - 775 mm , Impeller diameter rated m size - 623 mm , Impeller guide piece materials - ST ST.ASTM A+S49/M-CFM , Impeller Nut material - BR IS :318 Gr- LTB-2, Discharge Head Details material MS - IS:2062 Fe WA ,Delivery end dia -- 600 mm , Motor stool Head Details - material MS - IS:2062 Fe WA , Colum pipe , taper and distance Colum details :,materials - MS. IS:2062Fe4-10WA,size 600 mm ,Transmission shafts details –,Materials for Int. shaft, n shaft, Head shaft, Impeller shaft and sleeves Key and Muff coupling etc-- ST.ST.ASTM A - 276-410 ANLD, shaft dia shall not be less than 85mm,Bearing details - Materials for Bowl bearing spider Bearing -Neosprime with brass shell, Motor & Pump coupling details:, Materials for pump coupling - CS ASTM 105 forged , Material for coupling pin, bearing Nut lock nut - CS IS 1570-40C8 Hot RLD, Ratchet details : Materials for Ratchet cover and pin coupling - CS . IS 210 FG forged Thrust bearing type and size - Anti friction 29332E , material for journal bearing - CI FG 260 with lead base BABBIT<br> material for Thrust collar , Bowl and Bell mouth - CI IS 210FG260 <br> material for cooling pipe CU IS250/IS191P-V ANLD<br> delivery flange details - Flange OD - 750 mm, Flange ID - 600 mm , Flange No of Holes - 20 mm in hole size 31 mm,<br>Pump shaft size - 85 x 22 x 90 x 190 mm suction strainer (heavy duty) -1 nos(minimum 6mm,304 grade SS rod with full SS frame and nut bolts)<br>MOTOR: Supplying, erecting, testing and commissioning Schneider/ABB/Crompton/ BHEL / Equilent kwa approved make , IE3 or higher squirrel cage induction ,Totally enclosed fan cooled CACA , vertical solid shaft motor suitable for direct coupling with the above pump having RPM 960 or nearest capable to operate on voltage of 6.6 KV (+/ - 10 % ) 50 HZ,(+ /- 3% ) AC 3 phase, 50 degree Amb. temp rise ,Class F insulation, IP 55 degree of protection , with all standard accessories .PT 100 simplex type RTD's, . 6 Nos- PT 100 Duplex type bearing RTDs, 2 Nos -, preset, trip, reading bearing temperature meter for both bearings- space heaters conforming to relevant IS and IE rules . Efficiency : Minimum 90 % (Motor shall be energy efficient and supporting certificates to prove IE3 or higher as per IS 12615-2018 )-1Nos. STARTER: Supplying, erecting, testing and commissioning of fully automatic 6.6 KV FCMA Neutral soft starter control panel complete consisting with dust and vermin proof powder coated 3 mm thick steel, sheath for floor mount anti chemical paint coated panel board with following necessary parameters (1) off load Isolator (2) ,main 3 pole Vacuum contactor,(3) By pass Vacuum contactor , (4) programmable motor protection relay Micom 220 Schneider make for main protection-1no, additional fail safe ,motor protection Relay(C&S make Mpro100 or equivalent make-1no, (5), surge suppresser 3Nos 7.2KV (6)Current transformer for protection,( Bar current Transformer type),100A-15p10 (3 nos) separate class 1 window type current Transformer for metering 3 nos, 200/5A Class 0 .5 Current transformer for metering (7) HRC control fuses (8) 4KVA 6.6KV /110V rated PT for Starter control supply (9) 100 VA PT 6.6 KV/ 110V voltage indication, (10)single phasing preventer (11) Ammeter for starting current , (12)Voltage, ampere, frequency, power factor meter (1 Nos.) (13) soft starter unit , (14) neutral CT device, (15) Display indicators and (16) FCMA Panel Temperature supervision control relays to be connected in the starter components of Starter function (17) DC rectifier unit (18) 12E 110V <br> magnetic contactors for control (19) ON OFF Tripp healthy LED indicators conforming to relevant IS and CEA regulations ( starter function should be controlled from the internal PT. voltage )motor , Anti condensation heater controlled by start interlock & on delay timer (10 minute)- 1Nos,remote start stop/option, panel over temperature tripping relay with PT-100 probe(2 NOS).10 pair 1.5mm2 armored instrumentation cable for RTDS30mts,2.5mm2 armored two core cable for anticondensation heater, Trip announciating electronic heater provided with acknowledge push button,<br>CAPACITOR: Supply of make ISI marked 215KVAR, 6.6 KV capacitor conforming to IS 2834 (relevant IS) from KWA approved reputed manufactures like ABB,crompton, Shreemetc suitable for above motor for working with unity power factorwith capacitor duty HRC fuses , capacitor over current protection relay, Capacitor enclosed in starter panel -1No<br>VALVES: Supply of suitable size best quality ISI marked 600 mm size heavy duty cast iron double flanged sluice valve PN 1.6 suitable for above pump set ( to be suited existing foundation and inlet, outlet connections ) factory fitted detachable multi turn electrical actuator having following specifications and conditions :- 415V 3Phase 50Hz S2 duty serviceable 3Phase motor ,torque switches ON/OFF indications manual override hand wheel remote start/stop facility ,integrated starter etc. Actuator should capable for operating 600 mm sluice valve at 4.8kg/cm2 line pressure and time of duration required to fully open to fully close is not greater than 15 minutes -1No. Supply of suitable size best quality, ISI marked heavy duty cast iron 600 mm size double flanged reflex Non Return Valve as per PN 1.6 suitable for above pump set ( to be suited existing foundation and inlet, outlet connections )-1no<br>Supply reputed make 150 mm dia Fluid filled pressure gauge with Regulator cock and all accessories suitable for the above pump set -1set<br>CABLING: Supply of size 185sqmm PVC XLPE 7200V Gr insulated armored copper conductor cable conforming to relevant IS for giving power connection starter to motor etc. complete as per standards including end termination materials as per CEA regulation-45 M<br>Supply and providing 25x6 mm copper conductor with required materials for earthing the motor ,starter, capacitor etc as per CEA regulations -1Lot<br> Providing plate earthling using 1200mm x 12 mm size CI earth plate buried against at a depth of 3.00m from ground level with alternate layers at charcoal and salt including supplying fixing at 40mm dia perforated GI pipe funnel for water purpose etc. including the construction of masonry trough with man hole cover for motors, starter, capacitor and panel board etc. as per CEA regulations. 1 Job<br>ERECTION: Erection of the motor, pump set, starter panel boards, capacitors etc. on suitable concrete foundation with pump base plate giving power connecting cables to panel board to starters, starter to motor, capacitors, providing end termination, earthing of equipment supply fitting necessary pipes and specials to connect the delivery of pump set to the header pipe by necessary interconnection and fabrication etc. complete including taking trial run to the satisfaction of departmental officers including any other works and cost of materials required for the commissioning of the motor/ pump set as per standards including the rate for high voltage installations- 1No.<br>Motor R.T.D/P.T.C temperature scanner with over temperature trip facility.Remote start/stop facility provided near the motor.Emergency stop facility near the motor.Anti condensation heater controlled by MCB’s with anti condensation heater on indication lamp and ammeter (indication lamp sized ) for Knowing heater current. Panel must have anti condensation panel heater with auto thermostat.Panel temperature over heating tripping relay (with PT 100.Seperate three segment digital ammeter provided such a manner R,Y,B Current shows simultaneously.Soft starter must limit the starting current of motor into 2-4 times of its full load current.Trip announciating electronic buzzer, provide with acknowledge push button 10 Pair 1.5 mm² Armored instrumentation cable for R.T.D/P.T.C 30 Meters 2.5 mm² Armored two core cable for anti condensation heating 15 meters 1.5 mm² Armored four core cable for capillary meter gauge, remote start stop(30 Meter) and including charges for erection, cabling, earthing, commissioning of 6.6KV FCMA starter and panel board to starter & starter to motor cabling work(cable work complete) earthing and termination and allied works. Charges for erection ,commissioning of new vertical turbine pump set with the supervision of Authorized pump manufacture's Site Engineer concerned
OD292129/2023-2024:Charges for dismantling, existing 600 HP No3 Kirloskar make BHR 70 m model VT pump, dismantle 600mm nominal bore flanged delivery bend from, existing installation, remove 600mm sluice valve,600mm reflex valve, dismantle pump coupling, bearing box and its associated parts, gland stuffing box assembly, bearing and cooling assembles,7+1 nos column pipes with its shaft spider bearings, bowl assembly, suction strainer without any damages etc with its rivers engineering manner and taken away the dismantled parts in to workshop. including all loading and un loading charges, tools rent, special equipment rent with all incidental charges etc complete
OD9035/2024-2025:Dismantling of existing 600 HP motor, starter, foundation, cable/electrical connections , damaged panel board which erected in the place of pure water or raw water pump house as per the direction of departmental officers, dismantling un wanted electrical connections in the old instalation, conveying and stacking all the accessories in the HW store as per direction of departmental officers. Dismantling motor ,starter , cables , loading, unloading the motor, pump and starter of 600 HP installation with all incidental charges for machinery labour, transportation etc complete
2.1.1:Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including disposal of excavated earth up to 50 m and lift up to 1.5 m, disposed soil to be levelled and neatly dressed:All Kinds of soil
OD76007/2024-2025:Charges for multi turns electrical actuator fitting, cabling work from sub station to RWPH excluding E W excavation, termination, commissioning and other electrification works
OD292126/2023-2024:Additional warranty one year over and above the original warranty of one year
OD292127/2023-2024:Preparing and submission of electrical drawings and documents in connection with the proposed motor installations for getting official clearance and energization approval in connection with the existing scheme of the HW Chowara from Chief Electrical Inspectorate and KSEB
Appendix B: Sheet Roofing above 11 KV Substation
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
10.1:Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
OD67188/2024-2025:Roofing with Aluminium Trafford 0.40 mm thick sheet over the truss including cost of sheet,self screw of required standard size,fixing charge,making good to suit at site condition,fixing ridge(excluding cost of ridge) including labour and all incidental charges.
OD67187/2024-2025:Providing and fixing 220mm PVC sheet gutter Aquastar overall square gutter with elbow, centre joint, end joint, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete.
OD67186/2024-2025:Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete
10.16.3:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Electric resistance or induction butt welded tubes
10.25.1:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In stringers, treads,landings etc. of stair cases, including use of chequered plate wherever required, all complete
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
13.65.1:Painting with black anti- corrosive bitumastic paint of approved brand and manufacture to give an even shade:Two or more coats on new work
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
2.2.1:Earth work in rough excavation, banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with 1/2 tonne roller or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up in embankments for roads, flood banks, marginal banks and guide banks or filling up ground depressions, lead up to 50 m and lift up to 1.5 m:All kinds of soil
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
PAUL V.O. (BID ID -2158848)
Hydro Electrical Systems (BID ID -2143525)
Bidder Name
Hydro Electrical Systems
SRI ROYAL ELECTRICALS
PAUL V.O.
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1199947.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .