Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.9 LAccepted-AOC 205 2ND FLOOR VARDHMAN CHAMBER LL VIKASPURI WEST DELHI DELHI 110018 | WEST DELHI | DELHI | 110018 | ₹41.9 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹44.4 LRejected-AOC DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | ₹44.4 L | L2 | Rejected-AOC Rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical Documents found not correct. |
| Sl No | Description | Qty | Unit | Evaan Elevators Pvt. Ltd L1 | ELAN ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00 | PHASE - I
Design, Supply, Installation, testing and commissioning of electrically operated passenger lift (06 passengers) (gearless Machine) for 400 Kg capacity, with a speed of 0.40 mtr/sec adjustable to serve up to top floor of diving tank, with single speed motor 230 Volts, single phase, AC 50 Hz, with variable voltage & variable frequency drive ( VVVF drive) complete with all standard accessories, simplex automatic and mannual dual controlled operation with/without attendant, centre opening doors with door drive ( Electric motor driven mechanisam), sliding glass doors , car design with stainless steel silver sky finish and stainless steel support, Automatic rescue device (ARD) system, 2 D infrared sensor in full height of door & built in announcing system with hand set ( 03 Nos, one each in car & near ground floor landing) complete including Electrical control panel, electric power cable from nearest suitable LT Panel and steel structural complete fabrication works to install at open space including covering with ACP sheets of minimum thickness of 4.5 mm etc as per site requirement complete all as per OEM recommendations and as directed by EIC with following specifications :- | 1 | Each | 38,90,000 ₹38.9 L | 39,00,000 ₹39 L |
| 1.10Description :- (a) Vertical Lift model with gearless technology (b) Installation : Outdoor (c) Required pit depth : 100mm(As per OEM recommendation) (d) Hoist way dimensions: 1800 mm X 1500mm ( or as per OEM recommendation) (e) Lifting Capacity : 400 Kg (f) Machine Type : Gearless type (g) Speed : upto 0.40 m/s adjustable (h) Power supply : single phase 230v 50 Hz (j) Stops : 2 stops with sliding door (k) Landing Doors : Opening : (2100 mm (height)x 800 mm(width)( as per OEM and site conditions) (l) Type : Glass sliding door finished in SS satin Standard Cabin :- (a) COP : Black with built display and voice announcer (b) Cabin Size : (1100 mm (depth)x 1100 mm(width) x 2100 mm( height)) (c) Flooring : Granite (Black Stone) (d) Cabin Walls : Stainless Steel silversky finish with min 1.5 thickmess (e) Cabin door : Two panel automatic centre opening sliding door (f) Handrail : Round Handrail in SS (g) Communication : Telephone (h) Ceiling : Min 3 LED spots with one emergency light (j) Cabin display : TFT color display landing indicator and voice announcer (k) light curtains: Is included (l) Cabin controls : Automatic (one touch) with call reservation (m) Battery operated emergency lowering (UPS)/ ARD as per latest IS Make: Thyssen Krupp, Fujitech, Kone, OTIS, Escon | |||||
| 1.20Note :- 1. Civil works required for erection of lift like lift pit, RCC base of 500 mm thickness(100 mm hard core and 400 mm RCC M30 grade with 12 mm dia TMT Bar@150 mm c/c in both ways), Structural shaft with ISMB/ISMC standards as directed by the Govt authorised institutions of structural stability, lift well and external electric supply ,diversion of sewage lines, fire fighting pipelines, electric cables and water pipelines, any communication cables shall be carried out by the contractor as per OEM specifications/ site requirement and as per direction of GE/EIC. The ACP sheet to be enclosed complete with proper joint seals to arrest water entry and damages to the components. Necessary electrical cables from nearest existing LT panel and new elevator LT control panels shall be provided as per OEM reommendations and directions of EIC. The lift Head room packed with minimum 25 mm GI sheet puff panel to make sound proof with proper ventilation. The rate for the same shall be deemed to be included in the quoted rate. 2. Necessary concrete cutting of existing walls/beams to erect/ open the elevator door and std earthing of lift, connection of first floor elevator door to the diving tank floor with structural fabrication works and necessary alluminium chequered plate with hand rail works and roof with truss and ACP sheets upto the tank to easy/ safe entry for the passengers to the top floor and to match with existing diving tank structure/ arrangements etc shall be catered in the scope of work. The rate for the same shall be deemed to be included in the quoted rate. | |||||
| 1.303. The load, design and GAD of the elevator and structure, truss works frame shall be submitted by the contractor duly recommended by the OEM and vetted by IIT/NIT/Govt Engg college shall be submitted to the Accepting Officer before commencement of work. 4. Any special items/ accessories left out in the contract for successful completion of the work shall be provided by the contractor as per site requirement and the cost of the same deemed to be included in the unit cost. The tenderer and OEM should visit the site to check the feasibility and soil condition/ alternation civil works required at site before bididing the tender. 5. The necessary major components (steel section, guide rails, ACP sheet, base foundation etc) as per latest IS/BIS/OEM standards and sample approval of major components shall be taken by the contractor before starting the work. 6. The OEM should have a regional service center located in Kochi to attend day to day complaints. | |||||
| 2.00 | Supply and fixing and connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed.Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Mtr complete all as specified and as directed. | 25 | RM | 250 ₹6,250 | 500 ₹12,500 |
| 3.00 | Materials and labour for earthing complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly and vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with and including galvanised earth strip of size 32 x 6mm (Upto length of 7.5Mtr strip including) by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia complete all as specifed and directed. | 2 | Each | 8,500 ₹17,000 | 10,000 ₹20,000 |
| 4.00 | PHASE- II
Comprehensive maint of electrically operated passenger lift of capacity 400 Kg (06 passengers) with speed upto 0.4 m/s to serve ground floor and top floor of diving tank floor - 01 Nos installed under subject CA as per relevant item in BOQ complete with all as specified and as directed by Engr-in-Charge for First Year after completion of defects liability period (2028-2029) | 12 | Per lift per month | 7,500 ₹90,000 | 13,000 ₹1.6 L |
| 5.00 | All as per item No. 4 here in before but for second year after expiry of defect liability period (2029-2030). | 12 | Per lift per month | 7,500 ₹90,000 | 14,000 ₹1.7 L |
| 6.00 | All as per item No. 4 here in before but for third year after expiry of defect liability period (2030-2031). | 12 | Per lift per month | 7,800 ₹93,600 | 15,000 ₹1.8 L |
| 6.10Note for item No.4 to 6:- (a) The comprehensive maintenance shall be done through OEM/ authorised agency of the lift (b) The contractor shall enter into an MOU (Memorandum of understanding) with the OEM or their authorised agency for maintenance of the Lift. The above comprehensive AMC certificate shall be provided by the contractor in favour of GE (NS) before commencement of work, after acceptance of CA. (c) The parts shall be genuine and shall be from original Equipment manufacturer (OEM) and shall be as approved by GE. (d) All stainless steel parts such as lift car enclosure, opening doors, jamps, cills, etc shall be thoroughly cleaned to remove rust, stains, etc with suitable solution. The contractor shall also clean and properly maintain machine rooms, machineries and lift well as directed by EIC. The rates quoted for respective items shall be deemed to include for the same. (e) No spare parts and consumables shall be supplied by the department. (f) The rate of maintenance, service and repair including all the material and labour for the satisfactory functioning of the lfits. (g) Duration of maintenance is 12 months for 1 lift (h) Any breakdown/complaints shall be attend and rectify within 6 hrs. If the complaint is not attended and repaired within 24 hrs, penalty of Rs 2000/- per day will be charged. (j) The contractor is responsible to carried out periodical routine check up (Monthly/ Quarterly) through OEM (Once in a month) or as per contract agreement to ensure the serviceability and proper functioning of the lifts in all respect. (k) The contractor is responsible to clean/drain water from lift pit with necessary equipments. The rate for the same is deemed to include in the quoted rate. (l) After completion of defect liability period, If the contractor fails to submit MoU with OEM for comprehensive maint of lifts, a penalty of Rs 2000/- per day will be charged till submission of MoU. | |||||
Updated dates
Tender Value
₹46.5 L
EMD Value
₹92,920
Closing Date
1 Dec 2025, 6:00 pmClosed
Shri RK Singh IDSE CWE(NW) Kochi
CWE(NW) Kochi
PROVISION OF PIT LESS EMERGENCY CASUALTY EVACUATION LIFT FOR 10M DIVING TANK INCLUDING 03 YEARS COMPREHENSIVE MAINTENANCE AT DIVING SCHOOL NAVAL BASE KOCHI
2025_MES_737599_1
CWE(NW)KOCHI/81611
Open Tender
Civil Works
180 days
Kochi
As per NIT
6 documents required · 6 mandatory
₹500
GE(NS) Kochi
₹92,920
Yes
1 Jan 2026
29 Oct 2025
3 Dec 2025
29 Oct 2025
1 Dec 2025
12 Nov 2025
Amount
PHASE - I Design, Supply, Installation, testing and commissioning of electrically operated passenger lift (06 passengers) (gearless Machine) for 400 Kg capacity, with a speed of 0.40 mtr/sec adjustable to serve up to top floor of diving tank, with single speed motor 230 Volts, single phase, AC 50 Hz, with variable voltage & variable frequency drive ( VVVF drive) complete with all standard accessories, simplex automatic and mannual dual controlled operation with/without attendant, centre opening doors with door drive ( Electric motor driven mechanisam), sliding glass doors , car design with stainless steel silver sky finish and stainless steel support, Automatic rescue device (ARD) system, 2 D infrared sensor in full height of door & built in announcing system with hand set ( 03 Nos, one each in car & near ground floor landing) complete including Electrical control panel, electric power cable from nearest suitable LT Panel and steel structural complete fabrication works to install at open space including covering with ACP sheets of minimum thickness of 4.5 mm etc as per site requirement complete all as per OEM recommendations and as directed by EIC with following specifications :-
Description :- (a) Vertical Lift model with gearless technology (b) Installation : Outdoor (c) Required pit depth : 100mm(As per OEM recommendation) (d) Hoist way dimensions: 1800 mm X 1500mm ( or as per OEM recommendation) (e) Lifting Capacity : 400 Kg (f) Machine Type : Gearless type (g) Speed : upto 0.40 m/s adjustable (h) Power supply : single phase 230v 50 Hz (j) Stops : 2 stops with sliding door (k) Landing Doors : Opening : (2100 mm (height)x 800 mm(width)( as per OEM and site conditions) (l) Type : Glass sliding door finished in SS satin Standard Cabin :- (a) COP : Black with built display and voice announcer (b) Cabin Size : (1100 mm (depth)x 1100 mm(width) x 2100 mm( height)) (c) Flooring : Granite (Black Stone) (d) Cabin Walls : Stainless Steel silversky finish with min 1.5 thickmess (e) Cabin door : Two panel automatic centre opening sliding door (f) Handrail : Round Handrail in SS (g) Communication : Telephone (h) Ceiling : Min 3 LED spots with one emergency light (j) Cabin display : TFT color display landing indicator and voice announcer (k) light curtains: Is included (l) Cabin controls : Automatic (one touch) with call reservation (m) Battery operated emergency lowering (UPS)/ ARD as per latest IS Make: Thyssen Krupp, Fujitech, Kone, OTIS, Escon
3. The load, design and GAD of the elevator and structure, truss works frame shall be submitted by the contractor duly recommended by the OEM and vetted by IIT/NIT/Govt Engg college shall be submitted to the Accepting Officer before commencement of work. 4. Any special items/ accessories left out in the contract for successful completion of the work shall be provided by the contractor as per site requirement and the cost of the same deemed to be included in the unit cost. The tenderer and OEM should visit the site to check the feasibility and soil condition/ alternation civil works required at site before bididing the tender. 5. The necessary major components (steel section, guide rails, ACP sheet, base foundation etc) as per latest IS/BIS/OEM standards and sample approval of major components shall be taken by the contractor before starting the work. 6. The OEM should have a regional service center located in Kochi to attend day to day complaints.
Supply and fixing and connecting up Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe as directed/specified for loop earthing etc as required of galvanised iron strip of size 32 x6 mm complete all as specified and directed.Note; This item shall be measured for the quantity used at site after the length of strip 7.5 Mtr complete all as specified and as directed.
Materials and labour for earthing complete with galvanised iron earth plate electrode of size 600 mm x 600 mm x 6 mm thick, burried directly and vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with and including galvanised earth strip of size 32 x 6mm (Upto length of 7.5Mtr strip including) by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia complete all as specifed and directed.
PHASE- II Comprehensive maint of electrically operated passenger lift of capacity 400 Kg (06 passengers) with speed upto 0.4 m/s to serve ground floor and top floor of diving tank floor - 01 Nos installed under subject CA as per relevant item in BOQ complete with all as specified and as directed by Engr-in-Charge for First Year after completion of defects liability period (2028-2029)
All as per item No. 4 here in before but for second year after expiry of defect liability period (2029-2030).
All as per item No. 4 here in before but for third year after expiry of defect liability period (2030-2031).
ELAN ENGINEERS (BID ID -3483118)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.62 MB
Tenderdocument.pdf
Tender Documents • 1.33 MB
BOQ_825891.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid