GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
REPAIR TO LT OH LINE, PANELS FEEDER PILLAR BOXE, APEC, UG CABLE, IMPROVEMENT OF SUB STN AND INSTN, PAINTING OF POLE, OVERHAULING/REPAIR TO COOLING APPLIANCE, INTERNAL, PLUMBING, TILING AND PERIODICAL SERVICE TO BLDG AT MISA CAMP UNDER GE (S) TEZPUR
2021_MES_421972_1
8550
Open Tender
Civil Works
Item Rate
330 days
GE SOUTH TEZPUUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹99,750
Yes
19 May 2021
13 Feb 2021
17 Mar 2021
13 Feb 2021
15 Mar 2021
28 Feb 2021
Amount
Preparaing old plastered surface of wall and apply one coat of white wash,complete all as specified and as directed by Engr-in- charge
All as per Ser No 1 here-in -before but on ceiling .
M&L for preparation of old surfaces and applying one coat of Oil bound distemper with priming plastered surface on wall complete all as specified and as directed by Engr-in- charge
Praparation of plastered or unplastered old surfaces of wall, chajjas, soffits of chajja, slab projection etc and applying one coats of cement base paint all as specified and as directed by Engr-in-charge
M&L for preparation of old wooden sufaces of any description not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint of wooden surfaces complete all as specified and as directed
M&L for preparation old painted surfaces of steel and iron surfaces over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed
M&L complete removal of existing surface and appliying two coats of oil bound distemper over a coat of 3mm thick layer of wall care putty,complete all as specified and as directed by Engr-in- charge
Taking down cement plaster on brick walls incl racking out joints, hacking key & scrubbing down with water.
M & L 15mm thick rendering in cm(1:4) on fair faces of brick work or concrete surfaces and finished the surface even & smooth with WPC @ 3% by the weight of cement. (WPC Will be measured and paid seperately).
M & L 10mm thick rendering in cm(1:6) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement.
M & L 5mm thick rendering in cm(1:3) on fair faces of brick work or concrete surfaces and finished the surface even & smooth without using extra cement on ceiling
Supply only integral water proofing compound(make: Dr Fixit/Pedilite/fosroc)
M & L for two coats of exterior emulsion antifungus paint over a coat of primer to wall including complete removal of existing treatment complete all as specified and directed
M&L and applying two coats of cement base paint over a coat of primer on exterior wall surface.
M&L three coats of white wash on walls incl preparation of new surfaces.complete all as specified and as directed by Engr-in- charge
M&L three coats of white wash on ceilings incl preparation of new surfaces.complete all as specified and as directed by Engr-in- charge
M & L including preparation of surface of wall for Writing letters or figures at Buildings (Block. Roman, Italic or Indian) n exc. 30 cm high
Demolition cement concrete n'exc 15 cm thick (below or above ground level) as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat ), removing serviceable tiles to store and rubbish off the premesises
Dismantling water tanks and removing exc 500 but n exc 1000 ltrs capacity.
Taking up or down 15mm bore steel water tubing & connections, including cleaning for refixing or removal to store.
Taking up or down 20 mm bore steel water tubing & connections, including cleaning for refixing or removal to store.
S & F GI water tubes medium grade with all necessary fitting all as reqd complete of 15mm dia and fixed in walls/floor etc.
S&F tubes medium grade GI with all fittings fixed complete to walls and ceiling or laid in floors 20mm bore.
S&F 500 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified
S&F 1000 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified
S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms)
M&L 15mm thick screed bed in CM 1:6 for laying of floor finish complete all as sfd and directed.
M&L 10mm thick backing coat in CM 1:4 on brick or concrete surfaces for fixing of wall tiles as in dado/skirting.
S&F Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
S&F non skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile 300mmx300 mm, in floors etc, set and jointed in neat cement slurry and pointed in white or Coloured cement to match
S&F for colour Glazed ceramic tiles (250x350)/(450x350) of 7 to 8mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Taking down existing damaged IWC/EWC alongwith complete PCC and line concrete from sunken floor and providing new IWC and water proofing treatment to sunken floor as per following stage :- (i) 15mm thick plastering in CM (1:2) with WPC at all around and base of sunken floor with proper slope. (ii) Applying a coat of 85/25 gde hot bitumen @ 0.7Kg/Sqm over a coat of bituminous primer @0.5Kg/Sqm and then pasteing of polythene film, 150 micron, matural colour with cold cut back adhessive. (iii) Fixing of 25mm dia GI pipe (med gde) spout of length 45 cm.(iv) Supply & fixing of vitreous china squatting pan, "ORISSA" pattern or padestal type, size 580x440mm white with integral footrest, P/S trap etc complete including providing PCC lean concrete in Mix 1:5:10 complete.
Disconnecting existing tanks exc 500 L and n exc 1000 L, setting aside (or lowering if required) for water tanks, dewatering,cleaning and sterilisation with wire /brush/fine steel wire brush, clothes, removing all dirt and scale and algae formation inside the tank by using TERBAC G5(a lab tested chemical) including writing with yellow paint over base of the tank wall as "TANK CLEANED ON' with date, month and year with a minimum of 10 cm height capital letters/numbers. The cleaning process would follow fwg stages as under: (a) To drain out the water by using exit valve or high capacity dewatering system (b) Cleaning all the algae formation inside the tank by using TERBAC G5 chemical. (c) Scrubbing the walls with mechanised scrubber & fresh water cleaning by high speed jet pump. (d) 1st stage of bacteria screening by degermification by using TERBAC G5 halogen compound. (e) Cleaning the floor of the water tank by industrial vacuum cleaner. (f) 2nd stage of bacteria screening & sterilizing method by using UV ray within the tank & killing all suspended bacteria. (g) 3rd stage of bacteria screening by sterilizing the floor of water tank by using strong oxidizing agent TERBAC-G65.
Disconnecting existing tanks exc 1000 L and n exc 2000 L, setting aside (or lowering if required) for water tanks, dewatering,cleaning and sterilisation with wire /brush/fine steel wire brush, clothes, removing all dirt and scale and algae formation inside the tank by using TERBAC G5(a lab tested chemical) including writing with yellow paint over base of the tank wall as "TANK CLEANED ON' with date, month and year with a minimum of 10 cm height capital letters/numbers. The cleaning process would follow fwg stages as under: (a) To drain out the water by using exit valve or high capacity dewatering system (b) Cleaning all the algae formation inside the tank by using TERBAC G5 chemical. (c) Scrubbing the walls with mechanised scrubber & fresh water cleaning by high speed jet pump. (d) 1st stage of bacteria screening by degermification by using TERBAC G5 halogen compound. (e) Cleaning the floor of the water tank by industrial vacuum cleaner. (f) 2nd stage of bacteria screening & sterilizing method by using UV ray within the tank & killing all suspended bacteria. (g) 3rd stage of bacteria screening by sterilizing the floor of water tank by using strong oxidizing agent TERBAC-G65.
S&F in repairs Vitreous China wash hand basin white 550 x 400 mm including CP waste coupling and PVC Waste pipe fixed
S & F of central hole basin mixer, with round spout with pop up waste system with 450mm long copper pipes & brass nuts ( Make :Jaquar continental series cat No169
S&F fixed in repair itreous China EWC wash down water closet (padestal pattern, white) including PVC Sheet cover
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) including lime concrete bedding 1:2
S & F in repair PVC Low level flushing cistren 10 Ltr capacety including all fitting such as flush pipe brackets(Complete).
S &F in repair 125 mm brass CP shower rose swivel type fix to iron pipe all as directed.
S & F in repair 15mm Stop valves cast copper alloy with fancy type chromium plated with long shank and cup (Concealed Type) for iron pipe or for unions and fixed .
S & F in repair 15mm Angle Stop valves cast copper alloy,fancy type with chromium plated for iron pipe or for unions and fixed .
Dismantling and breakingup drain pipes AC /CI /PVC set in cement mortar 100mm/75mm bore.
S&F PVC (SWR) pipes single socketed in any length with rubberring joints fixed to walls or floor 110mm bore.(Make Prince/Supreme/Kisan)
S&F PVC (SWR) bends any radius 110mm bore in repairs
S& F PVC(SWR) junction single (single 'T') equal or unequal 110mm bore.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete fixed in repair
S&F pillar cock 15mm dia CP fancy type fixed in repair complete all as specified and directed.
M&L Applying two coats of distemper over a coat of 3 mm thick a layer of wall care putty on walls including preparation of surface
M/L 75mm thick P.C.C 1:3:6 type C-2 using 40mm graded stone aggregate as in plinth protection/sub base/path etc complete all as specified and directed.
S&F in repairs 15mm bore fancy type chromium plated bib cock long body with crutch or butterfly handle screwed down for iron pipes.
S&F in repair Tubular towel rail 20 mm dia with brass chromium plated
S & F in repair health faucet with 1.00 mtr tube and hook complete all as specified and directed. Make-Prayag Cat no BEA -81
S&F in repair Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device,complete all as specified and directed
S & F in repairs Waste coupling of brass chromium plated (half or full threaded) .(Jaquar/ Hindware)
S & F in repairs 32mm bore PVC Waste pipe for wash hand basin complete all as specified and directed
S & F in repair tank cover for PVC tank(500/750/1000Ltrs) cover with 6 mm dia MS bar hinging device and 6mm dia MS bar locking arrangement of 'S; type for monkey protection etc complete all as specified and directed
S&F in replacement of heating element of 2000 W (Round or Triangular Head as required at site) including rubber washer (ISI marked) etc complete all as directed
S&F in replacement of 450 mm long PVC connection suitable for hot & cold water supply with cromium plated brass screwed nuts at both ends with washers for making water connection of inlet & outlet from geyser to GI pipe 15 mm dia complete all as directed.
S&F in replacement of thermostat suitable for water heater of any size/type complete all as directed.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 1.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
S&F in replacement of plug top 3 pin 16 amps ISI marked complete all as directed
S & F in replacement of MCB SP 6-32 Amps, 240 V, 50 HZ breaking capacity 10KA, C series all as specified and directed.
M&L for wall fastener of size 100 mm long, 8 mm dia with double washers grouting making good in walls cement mortar (1:4) for fixing water heater, spilit AC outdoor after removing the existing unserviceable nuts /bolts and washers complete all as specified and directed.
S&F in replacement of sealed unit compressor suitable for Refrigarator/Deep Freezer of capacity upto 320 ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of sealed unit compressor suitable for water cooler of capacity 40/80 Ltrs including sealing of the compressor with welding after assembling complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
S&F in replacement of relay suitable for Refrigarator/ Deep Freezer/water Cooler of any capacity complete all as specified and directed.
S&F in replacement of evaporator coil unit complete suitable for Refrigarator/Deep Freezer of any capacity complete all as specified and directed.
S&F in replacement of tap chromium plated 15 mm dia suitable for water cooler all as specified and directed.
S&F in replacement of filter stainer of suitable for Refrigarator/Deep Freezer/water cooler/AC of any capacity all as specified and directed.
S&F in replacement of overload protector for Refrigerator/Deep Freezer/water coolers/AC all as specified and directed.
S&F in replacement of capacitor 6 MFD for AC/water cooler/Deep Freezer/Refrigerator complete all as specified and directed.
Supply and fix in replacement of ice chamber cabinet of Refrigerator of capacity upto 320 ltrs complete all as specified and directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-134a as required for Refrigarator/Water Cooler/Deep Freezer and testing the cooling effect satisfactorily on full load. The filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed. Note: Rate of Refrigrant R-134a shall be included in quoated rate.
M&L for servicing only in situ of Split type air conditioner 1.5/2.0 Ton capacity after removing electric wire connection & cleaning of Cooling coil, Filter, etc. including testing to cooling complete to entire satisfaction of Engr-in-Charge.
S&F in replacement indoor wall mounting unit of split type air conditioners electrically driven single phase of capacity 1.5/2.0 TR (make as required on site) including connection of pipe lines and charging refrigrant, testing complete all as specified and directed.
M&L for dismantilling Split type/Window Type air conditioner 1.5/2.0 ton capacity after removing indoor outdoor copper tube connection, electric wire connection and transporting to authorised workshop for reapir, including cleaning of Cooling coil, condenser coil, fan motor, filling of refrigerant R-22 etc. and re-installing the same after complete repair and testing complete all as specified and directed . Note:- R-22 Gas will be measured and paid separately as supply only under appropriate items here-in-after.
S&F in replacement of thermatically sealed compressor including sealing of the compressor with welding after assembling for 1.5/2.0 Ton Capacity Spilit type AC/ Window type AC complete all as specified and directed.
S&F in replacement of running capacitor 36-45 MFD for window type/Split type AC 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of starting capacitor 80-120 MFD for window type/split type air conditioner 1.5/2.0 Ton capacity complete all as specified and directed.
S&F in replacement of box type relay suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of copper condencer coil unit complete for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed.
S&F in replacement of capilary tube suitable for 1.5/2.0 Ton Split type/window type AC complete all as specified and directed..
S&F in replacement of fan blade with blower motor of window/split type AC 1.5/2.0 Ton, Refrigerator, deep freezer, water cooler capacity complete all as specified and directed.
S&F in replacement of control circuit (PCB) with remote device suitable for 1.5/2.0 Ton Split type AC complete all as specified and directed.
S&F in replacement of copper tube of size 1/2'' dia for connection of indoor and outdoor unit of split AC/window AC all as per directed by the Engineer-in-Charge.
S&F in replacement of copper tube of size 1/4'' dia for connection of indoor and outdoor unit of split AC all as per directed by the Engineer-in-Charge.
S&F in replacement of insulation cover of size 5/8" for insulating copper tube of split type AC all as per directed by the Engineer-in-Charge.
S&F in replacement of of flair nut for tighting the inlet valve of gas of desire size for connection of indoor and outdoor of split AC all as per directed by the Engineer-in-Charge.
S&F in replacement PVC insulated & PVC Sheathed three core cable of size 2.5 sqmm with copper conductor 1100 Volts grade conforming to IS:694/1990 ISI all as specified and directed.
M&L for leak testing with nitrogen dioxide and refilling with refrigerant R-22/R-32 as required for Split AC/Window AC and testing the cooling effect satisfactorily on full load and the filling of gas & testing shall be carried out in the presence of Engineer in Charge complete all as directed.
M&L for Shifting Split type AC 1.5/2.0 TR capacity including disconnection of out door & indoor unit, Re installed the same to new location after necessary servicing including testing and commisioning complete all as directed.
S&F in replacement of AC support bracket of size 500x500 mm ('L' Shape) 2mm thickness suitable for carrying maximum load 200-250 Kg including necessary fixing arrangements for installation of outdoor unit of split type AC complete all as specified and directed.
S&F in replacement of Sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 32 Amps, 240 volts capacity and tested on completion complete all as specified and directed.
S & F in replcement of MCB SPN 240 Volts, 6-32 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA all as specified and directed.
Supply and fix in replacement of Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 290 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA all as specified and directed.
Supply only refrigerant R-22 gas in air conditioner of any type make capacity complete all as speciifed and directed.
S&F in replacement of float valve assembly complete for water cooler 40/150 ltrs capacity water storage type all as specified and directed.
S&F in replacemet of heating element of capacity 3000W (Round or Triangular Head as required at site) suitable for solar water heater including rubber washer (ISI marked) etc complete all as directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 6 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
S&F in replacement 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
Material and labour for painting to steel tubular pole upto 3.0 metre long with two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with alluminium paint and MS frames like channel,clamps, angle, D-clamps etc with two coats of aluminium paint complete all as specified.
S&F in replacement of decorative Trim Clipon LED Panel light 12 Watt, 6500 K unique slimmest recess com surface panel, soul made up of high grade unbreakable polycorbonate material all as specified and directed. Make Havells, Cat No. LHEAABP7IL1W012
Supply and fix in replacement of loop in loop out junction box with SP 6-32 amp, IP 65 / IP 66 protection halogen free and weather proof of size (205x255x122) mm, fixed to Pole with suitable clamp including nuts and bolts and washers incl provision of connector fixed to pole all as directed. Make:- Hensel model No. DK 2525 G
M&L for earthing complete with GI earth plate electrode 600x 600 x 6 mm burried directly in ground vertical to a depth not less than 2.25 mtrs below ground level with the top edge of earth plat at a depth not less than 1.5 mtrs below normal ground level connected to GI earth strip in size 32x6 mm by means of nut bolts and washers etc. connected to sub LT Panel including necessary excavation earth work ,PCC (1:3:6) type C-1 using 20 mm graded stone aggregate earth chamber 40 mm thick RCC cover with PCC (1:2:4) type B-1 using 20 mm graded stone aggregate 40 mm dia GI pipe medium grade for watering, funnel, protection pipe ,adequate quantity of commen salt, charcoal etc. and connecting upto main sub panel complete all as specited and shown in electrical plate No. 3 of MES Sch Part -1 complete all as directed by GE.
Excavation in trenches not exc 1.5 m in depth and not exc 1.5 m wide for taking out/laying XLPE cable/CI/GI pipes and getting out in soft/loose soil complete all specified/directed
Removing excavation soil at a distance not exc 50 m and deposited where directed complete all as directed.
Returning,filling in including spreading, leveling, watering and well rumming in layers not exc 25 cm complete all as directed.
M&L for sand cushioning with clean dry sand for protection of under ground cable complete all as specified and as directed. Note :- Punned thickness of sand layer shall be measured and paid to contractor.
M&L for Brick Sub Class 'B' locally available best quality laid in trenches with width equal to length of the bricks, above sand cushioning for cable protection complete all as specified and as directed.
S&F in replacement steel water tubing 40 mm dia of bore light grade galvanised with all fittings laid in trenches / fixing with surface of wall after drawn through electric cable by means of nuts bolt and washers all as directed .
S&F in replacement steel water tubing 50 mm dia of bore light grade galvanised with all fittings laid in trenches / fixing with surface of wall after drawn through electric cable by means of nuts bolt and washers all as directed .
S&F in replacement steel water tubing 80 mm dia of bore light grade galvanised with all fittings laid in trenches / fixing with surface of wall after drawn through electric cable by means of nuts bolt and washers all as directed .
Supply and fix in replacement of MCCB 250 Amps, 4pole, 415volt, 36 KA breaking capacity with all the necessary electrical connections, all as specified and as directed. (Make: Legrand / L&T / Siemens / ABB /Schnieder
Supply and fix in replacement of MCCB 200 Amps, 4pole, 415volt, 36 KA breaking capacity with all the necessary electrical connections, all as specified and as directed. (Make: Legrand / L&T / Siemens / ABB / GE / Schnieder
Supply and fix in replacement of MCCB 100 Amps, 4pole, 415volt, 30 KA breaking capacity with all the necessary electrical connections, all as specified and as directed. (Make: Legrand / L&T / Siemens / ABB / Schnieder.
Supply and fix in replacement of MCCB 63 Amps, 4pole, 415volt, 30 KA breaking capacity with all the necessary electrical connections, all as specified and as directed. (Make: Legrand / L&T / Siemens / ABB / Schnieder.
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 6 sqmm 2 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 10 sqmm 2 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 16 sqmm 4 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 25 sqmm 4 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 35 sqmm 4 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 50 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 70 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 95 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 120 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 150 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
Supply,laying in repair in trenches of XLPE UG cable insulated aluminium stranded conductor served with an inner sheathing or PVC tape heavy duty armoured upto 1100volts (earthed) GI steeel strip and overall PVC sheathed nominal cross sectional area 185 sqmm 3.5 core and testing complete all as specified and directed. (Make:Havells India Ltd/ Richa/ KEI Industries Ltd/Polycab/ASIAN Cable/Finolex).
M&L for Boring holes horizontally under Road without damaging the surface of Road (minimum 1.0 METRE below the Road Surface / footpath with the help of GI Tubing not exc. 80mm bore (dia) for passing of UG Cable, complete all as specified and directed NOTE: GI Pipe laid will be measured and paid separately under appropriate Item.
Supply and fix in replacement of aluminium lug of size 16/25 Sqmm for connecting Aluminium XLPE cable all as specified and directed.
Supply and fix in replacement of aluminium lug of size 35 Sqmm for connecting Aluminium XLPE cable all as specified and directed.
Supply and fix in replacement of aluminium lug of size 50 Sqmm for connecting Aluminium XLPE cable all as specified and directed.
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Supply and fixing Pin type porcelain, vitreous white brown or green insulators including one galvanised mild steel spindle, two galvanised iron washers, and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and as directed. Make: BHEL/Jaipuriya Brothers/Pactil/Southern Insulators
Supply and fixing Shackle type, porcelain, vitreous, white brown or green insulators, including galvanised mild steel straps, washers, insulator bolts, washer and nut, 75 mm height, 90 mm dia, 3 Nos straps of size 31 x 3mm, dia of bolts for 1100 volts grade complete all as specified and as directed. Make: BHEL/Jaipuriya Brothers/Pactil/Southern Insulators
S&F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, complete all as specified and as directed.
M&L Stay Assembly complete with Accessories as show in Electrical Plate No.1 of MES Schedule Part-I, diameter of Stay Rod 16mm, size of Plate 230x230x6mm complete all as specified and as directed. NOTE: Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, etc., Loop Insulator, etc. will be measured and paid under approprite Items.
Supply and fixing galvanised stay strand of size 7/3.15mm complete all as specified and as directed.
Supply, fixing, errecting in trully vertically position steel tubular swaged welded pole complete with cast iron base plate, finial taper plug, bolts, nuts, and screws as specified type 410 SP - 31 (9 mtr long) including one primer coat, one under coat, one finishing coat of aluminium paint, marking of pole numbers and making 3 Nos of black colour strip 15 cm wide on equal distance from coping including suitable size of PVC cable jointing box with nut bolts and MS clamps made out with 20 x 5 flat iron complete all as specified and as directed.
M&L for cement contrete 1:3:6 type C- 2 40 mm graded stone aggregate as in foundation of pole filling and mass concrete in complete all as specified and as directed.
M&l for cement contrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in roof, kerb or mud stops rounded or charged on edges ,coping etc complete all as specified and as directed.
Supply, fixing / stringing aluminium conductor steel rainforced (ACSR) in any type /size/ dia etc on existing poles including winding, jumpering with alkathine pipe and binding to insulators with aluminium binding wire as in over head conductors including stringing, tightening etc complete all as specified and directed.
S&F Automatic Power Factor Correction (APFC) Panel for 3 Phase, 440 VAC & 50 Hz system of capacity 45 KVAR without incoming MCCBs all as specified and directed.
Supply and fix in replacement of Solar tubular battary 75/100 AH, Extra lead 20% higher backup, thicker tubes, long life,solar inverters,UPS,Emergency lighting complete all as specified and directed.
Supply and fix in replacement of SPN double door MCB distribution board sheet steel, powder coated 4 way fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
S & F in replacement of MCB TPN 415 Volts, 63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
Supply and fix in replacement of Solar charger controller (PWM)12V charger battery from solar panel, Protects battery from over charging/over discharging,protects panel from reverse current, suitable for 15 W luminaire complete all as specified and directed. Make: Havells/ Bajaj /Philips /GE /Wipro /Surya Roshni Ltd.
Supply and fixing LED fitting 20 watts 6000k very high efficiency enviormental friendly long life mounting on PVC round/square PVC block and making all connection using three core PVC insulated copper conductor muilti strandard flexible cable drawn through in PVC flexible conduit pipe from fitting to ceiling rose complete all as specified and directed.
S&F in replacement of LED gate light of 25 Watt made up of high grade unbreakable polycorbonate material all as specified and directed. Make Havells, Cat No. RUBYPT25WLED830SSYMTOPC /Crampton Greaves/Surya
Supply and fix in replacement on load change over switch AC-23A (side handle) with advance neutral switch in steel sheet metal enclosure 4 pole and 415 volts conforming to IS/IEC -60947-3 compact design of capacity 100 Amps complete all as specified and directed. Make: L&T/Legrand / ABB / Siemens / GE / Schnieder / C&S Electric Ltd / Indo Asian
Supply and fix in replacement on load change over switch AC-23 (side handle) with advance Neutral switch in steel sheet metal enclosure 4 pole By pass Switch and 415 volts conforming to IS/IEC -60947-3 compact design of capacity 63 Amps complete all as specified and directed. Make: L&T/Legrand / ABB / Siemens / GE / Schnieder / C&S Electric Ltd / Indo Asian Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
Ms N D Enterpise
M/S SEWAK SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .