Provision of backup protection plan during lightning surges at temporary campus of IIM Sirmaur at Paonta Sahib
2022_BSNL_138393_1
EE/E/BSNL/ED/SML/NIT/22-23/09
Open Tender
Fire & Safety
Item Rate
15 days
Shimla
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
BTCL HQ ND collection Current Account
₹9,576
Yes
23 Dec 2022
15 Dec 2022
23 Dec 2022
15 Dec 2022
21 Dec 2022
15 Dec 2022
Amount
S/F Type-1+2 AC surge protection device having poles TP+N ,Uc[v] -320 , In[KA]-20 , limp[KA]-12.5 , Imsx[KA]- 50 , Up[KV]-1.5 with cartridges having poles L-N ,Uc[v] -320 , In[KA]-20 , limp[KA]-12.5 , Imsx[KA]- 50 , Up[KV]-1.5 at main panel i/c connection , testing etc complete as reqd.
S/F Type-2 AC surge protection device having poles TP+N ,Uc[v] -320 , In[KA]-20 , Imax[KA]- 40 , Up[KV]-1.5 with cartridges having poles L-N ,Uc[v] -320 , In[KA]-20 , Imax[KA]- 40 , Up[KV]-1.5 at IT Office UPS supply i/c connection , testing etc complete as reqd.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing earth bus of 50 mm X 5 mm copper strip on surface for connections etc. as required.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.
Fixing of lightning conductor finial (single prong) with base plate including holes etc. complete as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run)
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
S/F 16 sqmm PVC insulated copper conductor flexible cable for extending earthing connections from copper strip / copper busbar etc complete as reqd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .