| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-AOC AT PO TALBANI CITY PASCHIM MEDINIPUR STATE WEST BENGAL PIN 721156 | PASCHIM MEDINIPUR | PASCHIM MEDINIPUR | WEST BENGAL | 721156 | ₹1.2 L Quoted ₹1.0 L | L1 | Accepted-AOC TECHNO COMMERCIALLY ACCEPTED |
| Sl No | Description | Qty | Unit | CHITTARANJAN MAITY L1 |
|---|---|---|---|---|
| 1.00 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP "B" ) | 43 | Nos | 1,055 ₹45,365 |
| 2.00 | Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 2.5 sq.mm. + 1x 2.5 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. | 115 | mts | 185 ₹21,275 |
| 3.00 | Wiringfor light/power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single corecable insurface/recessed medium class PVC conduit along with 1No.4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 65 | Mtr | 233 ₹15,145 |
| 4.00 | Supplying and fixing 5/6 amps modular switch on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. | 11 | Nos | 57 ₹627 |
| 5.00 | Supplying and fixing 5/6 amps modular socket on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. | 11 | Nos | 79 ₹869 |
| 6.00 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (Suitable for the BLDC type fans) | 5 | Nos | 240 ₹1,200 |
| 7.00 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | 5 | Set | 332 ₹1,660 |
| 8.00 | Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240V, onsurface/ recess, complete with tinned copper busbar, neutral busbar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator (16 way , Double door) | 1 | No | 2,955 ₹2,955 |
| 9.00 | Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C"-series Miniature Circuit Breaker suitable for inductive load of single pole in the existing MCB-DB complete with connections, testing & commissioning etc. as reqd. (single pole) | 12 | No. | 197 ₹2,364 |
| 10.00 | Supplying & fixing 63 amps rating,double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. | 1 | No | 700 ₹700 |
Updated dates
Tender Value
₹1.5 L
EMD Value
₹1,900
Closing Date
6 Apr 2026, 5:00 pmClosed
SO E AND M
OFFICE OF SO E AND M BASUNDHARA AREA MCL
Electrical Wiring of VTC (Vocational Training Centre) rooms at Basundhara Area.
2026_MCL_357324_1
MCL/GM/ BA/EM/e-Proc/2025-26/21 Date- 22/03/2026
Open Tender
Electrical and Maintenance Works
10 days
BASUNDHARA AREA
AS PER NIT AND TC
4 documents required · 4 mandatory
₹1,900
Yes
14 May 2026
23 Mar 2026
7 Apr 2026
23 Mar 2026
6 Apr 2026
24 Mar 2026
23 Mar 2026 - 26 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(GROUP "B" ) | |||||
| 2Wiring for circuit/ submain wiring alogwith earth wire with the 2 x 2.5 sq.mm. + 1x 2.5 sq.mm. earth wire of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. | |||||
| 3Wiringfor light/power plug with 2X4 sq.mmFRLS PVC insulated copper conductor single corecable insurface/recessed medium class PVC conduit along with 1No.4sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | |||||
| 4Supplying and fixing 5/6 amps modular switch on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. | |||||
| 5Supplying and fixing 5/6 amps modular socket on the exsiting modular plate & switch box including connections but excluding modular plate etc. as required. | |||||
| 6Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required (Suitable for the BLDC type fans) | |||||
| 7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | |||||
| 8Supplying and fixing following way, single pole and neutral, sheet steel,MCB distribution board, 240V, onsurface/ recess, complete with tinned copper busbar, neutral busbar, earthbar, din bar, inter connections, powder painted including earthing etc. asrequired. (But without MCB/RCCB/Isolator (16 way , Double door) | |||||
| 9Supplying and fixing 5 amps to 32 amps rating, 240 volts, "C"-series Miniature Circuit Breaker suitable for inductive load of single pole in the existing MCB-DB complete with connections, testing & commissioning etc. as reqd. (single pole) | |||||
| 10Supplying & fixing 63 amps rating,double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc.as required. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.37 MB
Tendernotice_2.pdf
PDF • 0.82 MB
BOQ_370186.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid