Loading…
Loading…
Tender Value
₹12.2 L
EMD Value
₹1 L
Closing Date
17 Jul 2026, 2:00 pm
Exe Eng NH Div. Rajkot
Exe Eng NH Div. Dr. Rajendra Prasad Road, Rajkot
M and R to All National Highways under jurisdiction of National Highway Division Rajkot for Electrification Work
2026_MoRTH_915695_1
05/04 of 2026-27
Open Tender
Civil Works - Highways
365 days
Rajkot
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,200
Bharatkosh Portal
₹1 L
3 Jul 2026
3 Jul 2026
18 Jul 2026
3 Jul 2026
17 Jul 2026
3 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Supplying and erecting street light pole bracket comprising main B class MS pipe of 4.2 cm require outside dia complete with suitable B class M.S. sleeve tubing of approx. 45 cms/length and suitable for 76.5 mm /80 mm/ require size of pole top having nuts and bo;ts for fixing the brackets and having spread of 0.5 mtr length with 110 deg. with verticle plane and suitable welded stiffner reducer and nipple with check nut complete painted with one coat of red oxide / PU base primer and two coats of Aluminum / PU paint with following nos. of arms. (A) single arm bracket 0.5 mtr. (Electrical work SOR 2022-23 item no.6-5-4-a) | - | Nos. | 525 | - |
| 1.02 | Supplying and erecting approved make octagonal pole made from HR sheet steel. The pole should be made as per IS. and shall be coated with hot dip galvanized as per IS 2629/2633/4759, suitable suspended local wind speed with integral junction box consist of terminal plate of min 6mm Hylam sheet, standard profile 35mm*7.5mm Din-Rail for MCB mounting, stud type terminal and arrangement for cable termination to be erected with suitable foundation (Included) as per details given by manufracture considering site requirement (i)10 mt longh 70 mm Top * 175 mm bottom dia 4 mm thickness with 275mm× 275mm × 16 mm Base plate, 4-M24 Bolts and 750mm long J-bolt Approx pole weight 145 kg (Electrical work SOR 2022-23 item no. 6-1-4) | - | Nos. | 23,100 | - |
| 1.03 | Providing and erecting, heavy duty flood light integral luminaire comprises die cast aluminium body with heat resistant toughned front glass, sillicon rubber, gasket, anodised reflector hot deep powder coated cradle clamp with suitable size of necessary build in control gear complete with lamp. LED street light / Flood light fittings with one number 250 Watt HPSV/Metal halde lamp (Electrical work SOR 2022-23 item no. 2-11-1-c) | - | Nos. | 5,500 | - |
| 1.04 | Point wiring for Light / Fan/ Bell/ Primary Point with 2-1.5 sq. mm & earth wire of 1.5 sq. mm (green) both are of ISI marked 1.1 kv grade FRLS PVC insulated multi strand copper wires upto max length of 10 mt, in below type of pipe erected with 6A Tissino Type ISI marked flush type switch / bell push and accessories erected on Metal / PVC/Wooden Box covered with 3 mm thick PC(Polycarbonate) /Acrylic/Laminated sheet. with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(j) in existing pipe erected concealed in wall/ceiling complete (Electrical work SOR 2022-23 item no. 1-1-1-j) | - | Nos. | 314 | - |
| 1.05 | Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI marked stranded Copper conductor wire in following type of pipe to be erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of green colour for earth continuity of following size
(E) in existing pipe,(a) 2 wire 1.5 sq. mm
(Electrical work SOR 2022-23 item no. 1-4-1-(E)-(a)) | - | Rmt | 51 | - |
| 1.06 | Supplying and erecting Flexible PVC insulated multi strand multi core 1.1 kv grade ISI marked copper wires of following size to be erected as directed.
(d) 1.50 Sq.mm 2 core round PVC sheathed
(Electrical work SOR 2022-23 item no. 1-4-5-(d)) | - | Rmt | 35 | - |
| 1.07 | Providing and erecting, heavy duty flood light integral luminaire comprises die cast aluminium body with heat resistant toughened front glass, silicon rubber gasket,anodised reflector hot deep powder coated cradle clamp with suitable size of necessary built in control gear complete with lamp.
(a) with one no. 70 watt HPSV / Metal halide lamp Cat. II
(Electrical work SOR 2022-23 item no. 2-11-1-(a)-Cat.II) | - | Each. | 2,700 | - |
| 1.08 | Supplying and erecting approved make, heavy duty polyester filled ballast suitable for HPSV/ Metal Halide lamp.
(A) 70 Watts Cat. II
(Electrical work SOR 2022-23 item no. 2-13-9-(a)-Cat.II) | - | Each. | 380 | - |
| 1.09 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection.
(vi)above 160 to 200 watts
(Electrical work SOR 2022-23 item no. 2-16-2-(a)-(vi)-Cat.II) | - | Each. | 9,920 | - |
| 1.1 | Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below description have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.)
(A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection.
(vii)above 200 to 250 watts
(Electrical work SOR 2022-23 item no. 2-16-2-(a)-(vii)-Cat.II) | - | Each. | 10,820 | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.