Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69,037Accepted-AOC | L1 | Accepted-AOC Accepted Vide Resolution No.I(1) dtd.25-08-2025 Nagaroor GP |
| Sl No | Description | Qty | Unit | UNNIKRISHNAN K V L1 |
|---|---|---|---|---|
| 1.00Electrical Works | ||||
| 1.00 | OD451023/2024-2025:Supply, conveyance, installation, testing and commissioning of 200 W LED Flood Light light output not less than 100lumen/W 4000-6000 K with IP 65 protection with power factor greater than 0.95 at full load, internal surge protection up to 8 KV and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%,RoHS compliant, duly wired up for use on 230 V AC supply(PWD approved make with ISI) | 3 | each | 8,300 ₹24,900 Lowest |
| 1.00 | OD451022/2024-2025:Supply, conveyance, installation, testing and commissioning of 150 W LED Flood Light light output not less than 100lumen/W 4000-6000 K with IP 65 protection with power factor greater than 0.95 at full load, internal surge protection up to 8 KV and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%,RoHS compliant, duly wired up for use on 230 V AC supply(PWD approved make with ISI) | 4 | each | 7,590 ₹30,360 Lowest |
| 1.00 | OD451019/2024-2025:Supply and fixing Timer Switch 24 Hours Programmable with IP 53cover ( Leggrand Maxi Rex 4QTB or equivalent) | 3 | each | 1,805 ₹5,415 Lowest |
| 1.00 | 1.17.30:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm | 37 | metre | 95 ₹3,515 Lowest |
| 1.00 | 2.15.2:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual
current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 1,377 ₹1,377 Lowest |
| 1.01 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 190 ₹190 Lowest |
| 1.01 | 2.13.1:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 1 | each | 760 ₹760 Lowest |
| 1.01 | 90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board | 28 | kg | 90 ₹2,520 Lowest |
Tender Value
₹81,225
Closing Date
19 Aug 2025, 2:00 pmClosed
ANILKUMAR K
OFFICE OF THE ASSISTANT ENGINEER, LID AND EW SECTION NAGAROOR PANCHAYATH
316 25 Maintenance of 3 nos highmast minimast lights at Nagaroor GP
2025_LSGD_783436_11
82/AE/LIDEW/NGR/2025-26
Open Tender
Electrical Works
Item Wise
180 days
NAGAROOR GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Exempted
16 Apr 2026
12 Aug 2025
22 Aug 2025
12 Aug 2025
19 Aug 2025
12 Aug 2025
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.29 MB
Tendernotice_2.pdf
PDF • 0.25 MB
Tendernotice_3.pdf
PDF • 0.25 MB
BOQ_1287796.xls
BOQ • 0.30 MB
SBD316.pdf
Tender Documents • 1.63 MB
PA316.pdf
Tender Documents • 0.26 MB
AFFDT316.pdf
Tender Documents • 0.24 MB
FOT316.pdf
Tender Documents • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .