Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC | ₹1.4 Cr | L1 | Accepted-AOC Agreement Executed |
| 2 | L2₹1.4 Cr+₹7.0 L (5.13%)Rejected-Finance | ₹1.4 Cr+₹7.0 L (5.13%) | L2 | Rejected-Finance Work awarded to L1 |
| 3 | L3₹1.5 Cr+₹10.1 L (7.38%)Rejected-Finance | ₹1.5 Cr+₹10.1 L (7.38%) | L3 | Rejected-Finance Work awarded to L1 |
| 4 | L4₹1.5 Cr+₹15.9 L (11.6%)Rejected-Finance | ₹1.5 Cr+₹15.9 L (11.6%) | L4 | Rejected-Finance Work awarded to L1 |
| 5 | L5₹1.5 Cr+₹15.9 L (11.6%)Rejected-Finance | ₹1.5 Cr+₹15.9 L (11.6%) | L5 | Rejected-Finance Work awarded to L1 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
5 Oct 2023, 2:00 pmClosed
The Superintending Engineer ,KWA, PH Cir
Office of the Superintending Engineer, KWA, PH Circle, Thiruvalla, Pathanamthitta
KIIFB- PWD- Rennovation of Anayadi- Koodal road (Pazhakulam-Kaikkalathupadi road)- Replacement of various size Distribution transmission main pipe lines.
2023_KWA_607142_1
175/2023-24/KWA/PHC/TVLA
Open Tender
Civil Works - Water Works
Item Rate
183 days
Adoor
As per NIT conditions and submitted Tender Documents
5 documents required · 5 mandatory
₹6,508
₹50,000
21 Dec 2023
26 Sept 2023
6 Oct 2023
26 Sept 2023
5 Oct 2023
26 Sept 2023
26 Sept 2023 - 5 Oct 2023
Amount
Distribution system
100.1.1:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50m, in all kinds of soil.
100.1.5:Excavating trenches of required width for pipes, cables, etc., including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering, etc., and disposing of surplus excavated soil as directed, within a lead of 50 m, in Ordinary Rock.
100.8.1:Fencing one side of trenches, 1.50m height with two rows of 10cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2m intervals.
100.8.2:Fencing 1.50m high with two rows of casuarina poles (girth 15cm to 24cm) tied with coir yarn on vertical casuarina pole (girth 15cm to 24cm) fixed at 1.5m intervals.
100.9.8:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 90 mm nominal outside diameter pipes.
100.9.9:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 110 mm nominal outside diameter pipes.
100.9.10:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 140 mm nominal outside diameter pipes.
100.9.11:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 160 mm nominal outside diameter pipes.
100.9.13:Laying uPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipeline to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipeline with water to the required test pressure (excluding cost of pipes and specials): 200 mm nominal outside diameter pipes.
100.37.7.1:In situ fabrication of M.S. pipes of size 200mm (I.D.) using 8mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete.
100.37.7.2:Fabricating M.S. flanges of diameter 200mm using 12mm thick M.S. plate including cost and conveyance charges of M.S. plate, all fabrication charges, charges of painting the steel work with two or more coat deluxe multi surface paint to give an even shade over an under-coat of primer etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.3:Cutting 200mm (I.D.) M.S. pipes for making bends and other specials by gas cutting including cost of gas, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.4:Welding 200mm (I.D.) M.S. pipes for making bends and other specials by gas/electric welding machine including cost of gas and welding rods, all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
100.37.7.5:Grinding cut and weld edges of 200mm (I.D.) M.S. pipes during fabrication work including all labour and hire charges of tools etc., complete: For pipes fabricated with 8mm thick M.S. plates.
18.30.5:Providing flanged joints to double flanged C.I./ D.I pipes and specials, including testing of joints:200 mm diameter pipe
100.12.9:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 100mm diameter nominal bore.
100.12.10:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 125mm diameter nominal bore.
100.12.11:Conveying and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc., but excluding cost of pipes and fittings for External work: 150mm diameter nominal bore.
100.31.1.4:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 150mm diameter, Class I.
100.31.1.5:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 200mm diameter, Class I.
100.31.1.1:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 80mm diameter, Class I.
100.32.3:Conveying and fixing C. I. Double Acting Air Valve of approved quality with bolts, nuts, rubber insertions etc., complete, but excluding the cost of air valve (tail pieces, if required, will be paid separately): 50mm Double Acting Air Valve.
100.31.1.2:Conveying and fixing C.I. sluice valves (with cap) by providing bolts, nuts, rubber insertions etc., complete, but excluding the cost of the valve (tail pieces, if required, will be paid separately): 100mm diameter, Class I.
OD95991/2023-2024:: Interconnecting 200mm DI and 110mm PVC pipe with Equal DI Tee and reducers.as specials including all cost of materials, labor charges etc... complete
OD97030/2023-2024:Interconnecting between existing 400 mm DI TEE with reducer pipe and newly laid 200 mm pvc pipe using suitable joints including cost of all specials & fittings, labour charge etc.. complete
OD97032/2023-2024:Interconnecting between newly laid160 mm pvc pipe and existing 200 mm DI pipe with Equal Tee and reducers.as suitable joints including cost of all specials & fittings, labour charge etc.. complete
OD97070/2023-2024:Interconnecting between existing 350 mm DI pipe with TEE and reducers .and newly laid 160 mm pvc pipe with Equal Tee and reducers.as suitable joints including cost of all Specials & fittings, labour charge etc.. complete
OD97075/2023-2024:Interconnecting between newly laid 160 mm pvc pipe and 90 mm pvc pipe with Equal Tee and reducers.as suitable joints including cost of all specials & fittings, labor charges etc. complete
OD97081/2023-2024:Interconnecting between existing 300 mm DI pipe and newly laid 140 mm pvc pipe with Equal Tee and reducers.as suitable joints including cost of all specials & fittings, labor charges etc. complete.
OD97109/2023-2024:Interconnecting between newly laid 140 mm pvc pipe and 90 mm pvc pipe with Equal Tee and reducers.as suitable joints including cost of all specials & fittings, labor charges etc. complete.
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
OD97163/2023-2024:Welding, cutting, grinding of 150mm/125 m.m/100mm/ GI pipes at required portions 3 runs welding including the cost of all labor charges cost of materials etc complete as per the direction of departmental officers.
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
4.3.2:Centering and shuttering including strutting, propping etc. and removal of form work for:Retaining walls, return walls, (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD97206/2023-2024:Constructing valve chambers in RCC 1:1.5:3 with 1.20M x 1.20M inside & depth 1.45m wall thickness 15 cm, cover slab 15 cm thick with base concrete in CC 1:4:8 thickness 10 cm, plastering etc. complete
OD97266/2023-2024:Constructing valve chambers with RCC of size 0.9x0.9x1.45M ,wall thickness 15cm and cover slab thickness 15cm with base concrete in CC 1:4:8 thickness 10 cm, plastering, including all cost of materials and labour charges etc. complete.
OD97281/2023-2024:Shifting interconnections the existing branch lines,Street taps,waterconnections to the new line including cost of specials & fittings, labour charges etc. complete.
50.2.26.1:Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-in-charge.
OD155091/2023-2024:GIS mapping, Drawings soft copy and hard copy(4Nos)submitted on each bill, and finally submitted the full data.GIS mapping coordinates of regular intervals regarding sizes and locations of pipes, valves, and other all attributes in order to proper asset management and future servicing of the system and in order to upload in google map.
Cost of Materials
100.98.223:Supply of PVC Pipe, 8kg/cm2, 90mm Dia.
100.98.224:Supply of PVC Pipe, 8kg/cm2, 110mm Dia.
100.98.225:Supply of PVC Pipe, 8kg/cm2, 140mm Dia.
100.98.226:Supply of PVC Pipe, 8kg/cm2, 160mm Dia.
100.98.227:Supply of PVC Pipe, 8kg/cm2, 200mm Dia.
OD125739/2023-2024:Cost of PVC specials (Bends, Tee, coupler, Tailpiece, end caps, solvent cement,CID/CIR etc )
OD125740/2023-2024:Cost of GI specials (Bends,Tee,coupler, Tailpiece,end caps,CID/CIR etc )
100.98.505:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 80mm.
100.98.506:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm.
100.98.508:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 150mm.
100.98.509:Supply of CI Plain End Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 200mm.
100.98.446:Supply of CI Air Valve, Conforming to IS 14848 - 2000, Double Orifice Type DS2, Size 50mm.
OD117947/2023-2024:GI Pipe Medium 125mm
OD117948/2023-2024:GI Pipe Medium 100mm
OD117992/2023-2024:Supplying 150 mm GI (m)
G ASHOK KUMAR
M/s PTC Infrastructures And Developers (P) Ltd
B AJITHKUMAR
Ajithkumar
Bidder Name
B AJITHKUMAR
G ASHOK KUMAR
Ajithkumar
Saji Abraham
M/s PTC Infrastructures And Developers (P) Ltd
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_905390.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .