Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.0 LAccepted-AOC | L1 | Accepted-AOC Lowest1 | |
| 2 | L2₹33.2 L+₹24,521 (0.74%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹34.0 L+₹1.0 L (3.09%)Rejected-Finance HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹34.4 L+₹1.4 L (4.19%)Rejected-Finance HIMACHAL PRADESH | L4 | Rejected-Finance Rejected | |
| 5 | L4₹34.7 L+₹1.7 L (5.24%)Rejected-Finance | L4 | Rejected-Finance Rejected |
Tender Value
₹68.7 L
EMD Value
₹1.0 L
Closing Date
18 Sept 2020, 11:00 amClosed
Executive Engineer
Jal Shakti Division Fatehpur
Sub Head supply and erection of Pumping machinery and laying jointing testing of rising mains of 150 mm dia and 100 mm dia
2020_HPIPH_40598_1
EE/JSD/FTR/EA/T/2020-5820-70
Open Tender
Civil Works
Item Rate
60 days
Tehsil Fatehpur
As per notice inviting tender
8 documents required · 8 mandatory
₹800
Executive Engineer, Jal Shakti Division Fatehpur
₹1.0 L
Yes
18 Dec 2020
11 Sept 2020
18 Sept 2020
11 Sept 2020
18 Sept 2020
11 Sept 2020
Amount
RISING MAIN & PUMPING MACHINERY:- Excavation in foundation treanches(Pipe & Pits) up to all depths in all classification of earth work such as pick work,jumper work,saturated soil including bailing or pumping out water,blasting soft /hard rock where blasting is prohibited in all lifts including trimming & dressing of sides leveling of beds to correct grade i/c shoring/strutting planking,timbering & dewatering wherever required stacking the usable & unusable material/soil separately & after laying,jointing & testing of pipes,returning the useable soil in trenches in 15cm layers including consolidating of such deposited layer by raming & watering & then disposing of all surplus excavated soil/unusable material as directed with in all leads & lifts including restoration of unmetalled surface to its original condition & including cost of diversion for traffic,night signals,fixing caution boards,crossing over trenches for access to houses,fencing etc.completein all respects with in all leads & lifts as per directions of Engineer-in-Charge.
Laying and jointing in trenches to be levelled to grade, BIS marked GI flanged pipes confirming to BIS:1239 (latest with upto date ammendments) of Following specified diameters (Medium class) duly flanged after 5th pipe with intermediate butt welded joints including the cost of flanges, bends/short pieces made from parent tubes of diferent degrees cutting welding and jointing with flanges conforming to tables as specified below of BIS: 6392 (latest with upto date ammendments) welded at both ends as per BIS:816 (latest with upto date ammendments) with electrodes confirming to BIS 814 (latest with upto date ammendments) & provided with nuts and bolts BIS: 1369 (latest with upto date ammendments) of required sizes 4 mm thick champion make compressed asbestos fiber gasket or synthetic rubber gasket confirming to BIS:2712 (latest with upto date ammendments) & approved specifications as per site conditions including flushing, cleaning & hydraulic testing complete to the best satisfaction of Engineer-in-charge.
Stage-I GMS pipe (Med. Class) 150 mm dia. Table-5
Stage-II GMS pipe (Med. Class) 100 mm dia. Table-17.
GMS pipe (Med. Class) 100 mm dia. Table-5
Pumping Machinery (Submersible Pumping Machinery) Stage -I:- Tube Well to Collection Tank Supply of submersible pumping set of (KSB /calama/Kirloskar/SU/ Johnston/Cromption/ BS/Sabar/Lubi) make conforming to BIS; 8034-1979 latest suitable for lifting clear water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-
Total Head : 43.99
Discharge required from each pump.: 12.00 LPS
No. of pump required :2.00 Nos. One act as stand by
Location of the site of installation of machinery: The site is located at distance of 5 Km from Bharmar Railway Station
The Altitude of installation : The altitude of place is 350 mtrs above MSL
Type of current : AC Three phase supply with
Rate Voltage: 415+ 10%
Type of water and its source: Clear water from T/Well
Charactristics of water.: -
a)Ambient Temperature dig.c: 20 dig. C
b)Turbidity NTU: 10NTU
c)Hardness260Mg/Ltrs(as CaCO3) :
e)total solid Mg /Ltrs
f)Other
Depth of Tube/Well: 150.00 mtrs.
LWL in Tube well
Center line level of Pump : 379 mtr
Discharge level of highest point: 419 mtr
Static head in Mrs
Length of R/Main : 53 mtrs.
Dia of Rising main: 150 MM
No of working hours per day: 8 Hours
Limit of pump operation: (-) 15 % (+) 10% of total head
R.P.M. of pumping set. : 2900 RPM ( or to be specified by the tenderer)
Test run : 8 Hours continueously for 7 days
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/ Leader make of size 150mm.and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. NOTE:-The C.I.Sluicew valve shall conform to BIS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump(size 150mm.dia and clasas PN 1.0and shall be suitable for withstanding nominal seat pressure of ___10.20__Kgs. cm<2
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I./Cast Steel double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main i.e. 150mm.& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm<2). Note:-The C.I.Reflux valve shall conform to BIS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in BIS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motors and other electrical equipments.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Providing and laying of column assembly of 100mm dia and common Header 100mm dia GI pipe 4mm thick confirming BIS 1978-82 considering site requirement dully flanged at every 30 mtr length with flanges confirming to BIS6392-1971 (T-5) including tapers, flanges, rubber gasket 3mm thick as per BIS -2712-1978, Nut & Bolts as per 1364-1983 and specials upto collection tank as per direction of Engineer-in-Charge. The pipe shall be capable of with standing FTP equal to 1.5 times the total pressure indicated in item No. 3(ii).
100 mm dia
100 mm dia
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge Errection of all equipments including cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Pumping Machinery (Centrifugal Pumping Machinery) Stage-2nd from Node-2 to Node-3 Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head: 59.90 Mtrs.
Discharge required from each pump.: 12.00 lps
No. of pump required: 2.00 Set (One act as stand by)
Location of the site of installation of machinery: The site is located at distance of 5 Km from Bharmar Railway Station
The altitude of installation.: 390 MSL.
Type of current.: AC three phase supply with freqduency of 75cycle per second.
Rate Voltage: 415+ 10%
Type of water and its source: Clear water.
Shaft level: 415
Level of discharge point: 454
Static Head: 39
Charactristics of water.
a)Ambient Temperature dig.c
b)Turbidity NTU
c)Hardness260Mg/Ltrs(as CaCO3)
e)Total solid Mg /Ltrs
f)Other
Depth of well assembly
No. of working hours per day: 8.00Hours.
Length of Rising main: 2600 Rmts.
Dia of Rising main: 150 mm G.I. pipe
Limit of pump operation.: In the completem Range of (-)75% .
R.P.M. of pumping set: 2900 RPM (or to be specified by the tenderer)..
Test run.: 8 Hours contineously for 7 days.
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/ Leader make and Class PN 1.0 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 10.20Kgs/Cm2. NOTE:-The C.I.Sluicew valve shall conform to BIS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I. double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump( clasas PN 1.0 and shall be suitable for withstanding nominal seat pressure of ___10__Kgs. cm<2)
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I. double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main .& class PN 1.0 shall be suitable for withstanding nominal seat pressure of 10.20Kgs./Cm<2). Note:-The C.I.Reflux valve shall conform to BIS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in BIS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motors and other electrical equipments.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments and making all kind of connections as per site requirement including cost of tees,flanges, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Lowering & jointing of Delivery/sunction pipe conforming to BIS:1978-82/BIS-1239-1990 of suitable size of suction, delivery and common header considering site requirement & NPSH required/available. The pipe size for suction and delivery shall as per the requirement of offered pump and common header shall be3 equal to dia of Rising main icnluding cost of tappers, flanges Table-17 (confirming to relevant table of BIS-6392-1971) bends, rubber gasket, 3mm thick nuts, & bolts and specials upto 5 mtrs away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge. Pipe & material shall be capable of with standing field test pressure equal to 1.5 times the operating pressure. Note:- size of dia of pipe i.e. suction/delivery pipe specified by the tenderes
The complete arrangement shall be comprise of: (a) Suction pipe ---mm dia GI Pipe (Medium Class)
(b) Delivery pipe ----mm dia GI Pipe ( Medium Class)
( c) Common header 100 mm dia GI Pipe (Medium class)
Pumping Machinery (Centrifugal Pumping Machinery) Coll. Tank to main storage tank at village Khurd Junat Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head: 124.85 Mtrs.
Discharge required from each pump.: 6.81 lps
No. of pump required: 2.00 Set (One act as stand by)
Location of the site of installation of machinery: The site is located at distance of 5 Km from Bharmar Railway Station
The altitude of installation.: 450 MSL.
Type of current.: AC three phase supply with freqduency of 75cycle per second.
Rate Voltage: 415V + 10%
Type of water and its source: Clear water.
Shaft level: 450
Level of discharge point: 549
Static Head: 99
Charactristics of water.
a)Ambient Temperature dig.c
b)Turbidity NTU
c)Hardness260Mg/Ltrs(as CaCO3)
e)Total solid Mg /Ltrs
f)Other
Depth of well assembly
No. of working hours per day: 8.00Hours.
Length of Rising main: 1280 Rmts.
Dia of Rising main: 100 mm G.I. pipe
Limit of pump operation.: In the completem Range of (-)75%
R.P.M. of pumping set.: 2900 RPM (or to be specified by the tenderer).
Test run.: 8 Hours contineously for 7 days.
Providing C.I.double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/ Leader make and Class PN 1.6 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 21.00Kgs/Cm2. NOTE:-The C.I.Sluicew valve shall conform to BIS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make C.I./Cast steel double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump( clasas PN 1.6 and shall be suitable for withstanding nominal seat pressure of ___21__Kgs. cm<2
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make C.I./Cast Steel double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main & class PN 1.6 shall be suitable for withstanding nominal seat pressure of 21.00Kgs./Cm<2). Note:-The C.I.Reflux valve shall conform to BIS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in BIS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motors and other electrical equipments.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments and making all kind of connections as per site requirement including cost of tees,flanges, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Lowering & jointing of Delivery/sunction pipe conforming to BIS:1978-82/BIS-1239-1990 of suitable size of suction, delivery and common header considering site requirement & NPSH required/available. The pipe size for suction and delivery shall as per the requirement of offered pump and common header shall be3 equal to dia of Rising main icnluding cost of tappers, flanges Table-17 (confirming to relevant table of BIS-6392-1971) bends, rubber gasket, 3mm thick nuts, & bolts and specials upto 5 mtrs away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge. Pipe & material shall be capable of with standing field test pressure equal to 1.5 times the operating pressure. Note:- size of dia of pipe i.e. suction/delivery pipe specified by the tenderes
The complete arrangement shall be comprise of: (a) Suction pipe ---mm dia GI Pipe (Medium Class)
(b) Delivery pipe ----mm dia GI Pipe ( Medium Class)
( c) Common header 100 mm dia GI Pipe (Medium class)
Pumping Machinery (Centrifugal Pumping Machinery) Coll. Tank to main storage tank at village Khor Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.
Total Head: 177.05 Mtrs.
Discharge required from each pump.: 5.19 lps
No. of pump required: 2.00 Set (One act as stand by)
Location of the site of installation of machinery: The site is located near Bharmar Railway station
The altitude of installation.: 450 MSL.
Type of current.: AC three phase supply with freqduency of 75cycle per second.
Rate Voltage: 415V + 10%
Type of water and its source: Clear water.
Shaft level: 450
Level of discharge point: 588
Static Head: 138
Charactristics of water.
a)Ambient Temperature dig.c
b)Turbidity NTU
c)Hardness260Mg/Ltrs(as CaCO3)
e)Total solid Mg /Ltrs
f)Other
Depth of well assembly
No. of working hours per day: 8.00Hours.
Length of Rising main: 3480 Rmts.
Dia of Rising main: 100 mm G.I. pipe
Limit of pump operation.: In the completem Range of (-)75% .
R.P.M. of pumping set.: 2900 RPM (or to be specified by the tenderer).
Test run.: 8 Hours contineously for 7 days.
Providing Cast steel double flanged sluice valve of Kirloskar/Kilburn/IVC.\/Fouress/Gled/BHEL/ Leader make Class ASA-150 having one size higher to delivery size of Pump and capable of withstanding nominal seat pressure of 21.00Kgs/Cm2. NOTE:-The C.I.Sluicew valve shall conform to BIS-780-1984(Latest edition). However if the seat pressure exceeds the limits prescribed in BIS-780-1984 then it shall be of cast steel conforming to Class-150 ASA(seat pressure 21 Kgs./cm<2.) or class 300 ASA(Seat pressure 52Kgs./Cm3)as per BS-1414(API-600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader make Cast steel double flanged swing Check type Reflux Valve having bye pass arrangement and one size higher to delivery size of pump( clasas ASA-150 and shall be suitable for withstanding nominal seat pressure of ___21__Kgs. cm<2
Supply of Kirloskar/Kilburn/IVC/Foluress/Gled/BHEL/Leader make Cast Steel double flanged Swing Check Type Reflux Valve having bye pass arrangement and of size equal to dia of Rising Main .& class ASA-150 shall be suitable for withstanding nominal seat pressure of 21.00Kgs./Cm<2). Note:-The C.I.Reflux valve shall conform to BIS-5312-1984-Part-I(Latest edition). However, if the seat pressure exceeds the limits prescribed in BIS-5312-then it shall be of cast steel conforming to Class 150 ASA Seat Pressure 21Kgs/Cm<2) or class 300 ASA)Seat pressure 52Kgs./Cm<2) as per BS 1868(API 6D).
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing & laying PVC insulated jointless, flat water proof copper cable of 3.5 core of suitable size Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost. The size of cable will be specified by the tenderer.
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motors and other electrical equipments.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
Errection of all equipments and making all kind of connections as per site requirement including cost of tees,flanges, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Lowering & jointing of Delivery/sunction pipe conforming to BIS:1978-82/BIS-1239-1990 of suitable size of suction, delivery and common header considering site requirement & NPSH required/available. The pipe size for suction and delivery shall as per the requirement of offered pump and common header shall be3 equal to dia of Rising main icnluding cost of tappers, flanges Table-17 (confirming to relevant table of BIS-6392-1971) bends, rubber gasket, 3mm thick nuts, & bolts and specials upto 5 mtrs away from the outer wall of pump house as per layout drawing approved by Engineer-in-charge. Pipe & material shall be capable of with standing field test pressure equal to 1.5 times the operating pressure. Note:- size of dia of pipe i.e. suction/delivery pipe specified by the tenderes
The complete arrangement shall be comprise of: (a) Suction pipe ---mm dia GI Pipe (Medium Class)
(b) Delivery pipe ----mm dia GI Pipe ( Medium Class)
( c) Common header 100 mm dia GI Pipe (Medium class)
Sarabjit Singh Katoch
SS ENGINEERING WORKS
Ravinder Kumar
A.K. Traders
RANBIR SINGH
dinesh kumar lath
SG Engineers and Consultants
VIVEK KUMAR
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .