| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance SOBHA ELECTRIC CHANGANASERY KOTTAYAM | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance MEDICAL COLLEGE KOTTAYAM PHASE I GENERAL ELECTRICAL WORK ADDITIONAL WORKS OF BASEMENT FLOOR KERALA KL | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹4.5 L
EMD Value
₹6,700
Closing Date
26 Aug 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant engineer
Kottayam Muncipal office
Electrification of Animal Birth Controls Building at Kodimatha under Kottayam Municipality
2021_LSGD_434767_1
61/eP/KMC/2021-2022
Open Tender
Electrical Works
Item Rate
66 days
Kottayam Muncipality
Please refer Tender documents.
5 documents required · 5 mandatory
₹900
Yes
₹6,700
Yes
1 Sept 2021
16 Aug 2021
1 Sept 2021
16 Aug 2021
26 Aug 2021
16 Aug 2021
60 days
Amount
Part I- Electrification (Materials used for the work shall be as per the List of materials approved by the D.L.T.C.E, attached as separate documen
90.2.1.1 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.8 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.4 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.3 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.10 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).
90.2.1.6 : Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
od1080873/2020_2021 : Supply and fixing angle / straight brass lined skirt type, bakelite batten holder with out shade with 9W LED and giving connection etc as required
od1080874/2020_2021 : Supply and installation of LED tube light fittings (Philips Endura high efficiency BN 308 C LED 20 S -6500 PSU WH) directly on wall/ceiling with company made mounting accessaries and giving connection with 16/0.20mm 3 core copper conductor flex wire.
od1093534/2020_2021 : <br>Supply and installation of LED tube light fittings (Philips Endura high efficiency BN 308 C LED 20 S -6500 PSU WH) on ball and socket arrangements on ceiling /truss work using special mounting clamps on T.W round block and using company made clamps with suspension down rod of 19 mm dia MS conduit up to 2x30cm length including painting and wiring the down rod with 16/0.20mm 3 core round copper conductor flex wire conforming to relevant ISS and giving connections etc as required.<br>
90.4.1 : Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
od1080875/2020_2021 : Supply and installation of 1200mm sweep ceiling fan with standard accessories with out reglator including giving connection with 16/0.20 mm 3core round copper conductor flexible chord etc as required.(Crompton (High speed)/Havells(SS-390)conductor flex wire or with extended original wiring etc. as required.<br>
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
od1080876/2020_2021 : Supply and installation of 150 mm medium duty 2300 rpm ,4 leaf exhaust fan in metal frame (Almonard/Crompton make) in the existing opening, fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of 24/0.20 mm 3core round copper conductor flexible chord etc required.
90.6.10.1 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.6 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 1.5 sq. mm
1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.15 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 2.5 sq. mm
1.17.21 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.27.1 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
od1082271/2020_2021 : Supply & Fixing 2module metal box with white/ off-white front plate provided with one 20A socket modular type in recess including making good the damages, colour washing etc as required (ROHS) including giving connections (Modular boxes ,switches and accessaries ,Make-Legrand Myrius/MK Blenz/Havells Oro/Hager/L&T)
od1082273/2020_2021 : Supply & Fixing 2module metal box with white/ off-white front plate provided with one 20 A DP modular type switch in recess including making good the
1.27.2 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
1.27.5 : Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
2.3.3 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.3.2 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door
90.11.1.14 : Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
od1081512/2020_2021 : Earthing with G.I. earth pipe 2 metre long 40 mm dia (medium class) including providing 12 mm dia drilled holes minimum 20 nos along the entire length in alternate arrangement providing 40x25 mm GI reducer at top and test joint using 2 nos ,25x3mm GI Strip minimum size 25 cm suitably shaped and tightly clamped to the pipe electrode using 25x6 mm steel bolts nut and washer and providing 2 nos, 6 mm dia drilled holes for clamping and bolting earth lead ,providing GI funnel welded with the GI reducer at top and making masonry chamber with cover plate having locking arrangement and etc. ( charcoal and salt as required shall be filled at 30 cm dia around the earth electrode)
od1081513/2020_2021 : Supplying and fixing DP sheet steel enclosure in recess including charges for cutting fixing and making good the damages on wall etc as required.
od1081515/2020_2021 : Supply and laying of bare earthing conductors of the following sizes below ground level including excavating trench of suitable size and refilling etc. 3.15.00 mm copper conductor ( 10 SWG)
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.
od1081519/2020_2021 : Supply and providing 12x3 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
od1093366/2020_2021 : Supply of 3 KVA/72V DC True On line Double conversion IGBT based UPS (HYKON make),(Model-HT 1103 L) single phase with 6 nos 100 AH ,12V,Tubular battery (HYKON make) with battery rack and stand for UPS
od1093416/2020_2021 : Supply ,installation testing and commissioning of 2 Ton 3 star Air conditioning unit with low power consumption, High wall mounting split type suitable for Single phase suitable for operating on 230V ,50 HZ single phase A.C supply and fitted with rotary compressor operating on R 32 Gas refrigerant ,copper condenser with copper piping (max 3 m) with insulation ,control cable up to 5 m, drain piping 3 m, microprocessor control with cordless remote etc.( Blue Star -Model No.IC326YATU/Equilent make Mitsubhishi/General make) company direct installation.
od1093897/2020_2021 : Supply ,installation testing and commissioning of 1 Ton 3 star Air conditioning unit with low power consumption, High wall mounting split type suitable for Single phase suitable for operating on 230V ,50 HZ single phase A.C supply and fitted with rotary compressor operating on R 32 Gas refrigerant ,copper condenser with copper piping (max 3 m) with insulation ,control cable up to 5 m, drain piping 3 m, microprocessor control with cordless remote etc.( Blue Star -Model No.IC312CATU/Equilent make Mitsubhishi/General make) company direct installation.
od1093898/2020_2021 : Supply conveyance installation testing and commissioning of 3 KVA Voltage stabiliser (V-guard) with input voltage 170 to 270 V and out put voltage range of 210 to 230 V with over load protection(cutt off) time delay,indicators,etc.as required.
od1083139/2020_2021 : Supply and providing company made bracket suitable for mounting the out door unit of A/C unit suitably mounted to the the wall as required
1.21.5 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.50 mm
90.6.10.2 : Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required
od1327769/2021_2022 : Supply and installation of dust and Vermin proof wall mounding meter box (600x350x170mm )SINTEX make with base plate suitable to fix single phase energy meter and fix to fix in the box 3 NOS of 32 A,415 V HRC bakelite fuse fitting with HRC fuse link,32 A 2 way neutral link etc
od1327770/2021_2022 : Supply and providing anchor bolt hook type on wall /parapet for binding KSEB Service connection cacable as required.
od1327771/2021_2022 : Charges for preparing drawing of the complete Electrical installation after completion of the present work and preparing completion report with KSEB service connection application form and submitting to the consumer for availng 3 phase service connection/Load regularization
Part-II -Remuneration.(As per G.O.No.2878/2015/LSGD dated 22/9/2015). Not part of BOQ
AJESH K K
Bidder Name
Mighty
AJESH K K
stage.html
html • 0.02 MB
finance_617738.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .