ELECTRIFICATION AND INSTALLATION OF LIGHT AT GANDHI SQUARE
2025_DP_803335_1
SC1/3//2025-26/LSGD/NML
Open Tender
Electrical Works
Item Rate
ELECTRIFICATION AND INSTALLATION OF LIGHT AT GANDH
Please refer Tender documents.
8 documents required · 8 mandatory
₹585
Yes
₹6,598
Yes
14 Oct 2025
27 Sept 2025
14 Oct 2025
27 Sept 2025
13 Oct 2025
27 Sept 2025
Amount
Installation of Lights
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
1.54.2:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group B
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way, Double door
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps
OD284668/2025-2026:Suppply and providing pipe earthing as per IS 3043 with 2.6 m long 40 mmdia B class GI pipe,GI funnel with weld mesh,filling required quantity of charcoal&amp:salt including construction of1:4:8 PCC using 40 mm broken stone(10 cm thick) brick work in mortar1:6,plastering the surface of brick masonary and the exposed surface of PCC bed with cement mortar1:4:12 mm thick(the finished inside dimension shall be 300X300X300.
OD284669/2025-2026:Fabrication, supply & installation of dust and vermin proof, wall mounting, Sintex make Code No 3525/Metal Type meter box suitable for fixing KSEB meter,fuse units, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit.
OD284670/2025-2026:Preparation of all drawing submitting and approvel from KSEB, obtaining power allocation, submitting of completion certificates and arranging inspection, getting sanction and energisation certificates from KSEB and obtaining power connection (single phase connection) etc: for commissioning of the whole installation in the permises.
OD284671/2025-2026:32/63 A fuse holder for BS type blade fuses.
OD284672/2025-2026:32/63 A, 230 V, DIN type fuse base.
OD284673/2025-2026:32/63 A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
14.4:Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
OD284675/2025-2026:Providing and laying in position reinforced cement concrete 1 :2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of High Mast/Mini Mast/DG set etc. including form work etc. as required (including reinforcement).
90.12.1.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
90.6.5.18:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 1.50 sq mm
OD295580/2025-2026:Supply installation testing and commissioning of Decorative Type Combo garden pole with Triple Arms show Lights made out of Cast iron body with suitable base plate to mount on foundation block with nuts and J type bolts pole shafts, cast iron section bracket arms to hold drop down/post top Luminaries depending upon required wattage for 3 Mtr Pole height. Each and every cast piece is pre-treated to remove all its external dirt and residues etc. Finish: durable UV resistant Poly Urethane(PU) paint available in range of many RAL colours. The pole surface shall also be pre-treated before painting. Service window: A suitable service window shall be provided at the bottom of pole to allow access to electrical connections and terminations. 3 meter Cast iron garden pole with 3 arm Luminary show Light of 18 watts.
90.12.1.13:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 6 sq mm
90.12.10.2:Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation50/38 mm or nearest size
OD301146/2025-2026:Supply, conveyance, installation, testing and commissioning of 100 Watts single piece LED Flood light fittings suitable for roadway installation with pressure diecast aluminium housing with corrosion resistance powder coating using Nano technology, natural cooling system,, Poly Carbonated UV treated diffuser for higher impact strength and optimum light transmision, High efficient driver with short circuit, over voltage, over courent and thermal protection, Surge protection up to 5 KV, PF 0.95, IP 65 protection, Horizontal Pole Mounting type fittings with all connected accessories fixing on the existing armand giving connections with 1.5 sq. mm 3 core PVC insulated and PVC sheathed copper conductor fles wire etc. as required The LED fittings shall be guaranted for 3 years from the date of commissioning from any defects in manufactring. Any of the spares / components which are found to be defective during this period shall be replaced immediately at free of cost. (Make: Philips/ Crompton/ Havells )-100 Watt Flood light
OD303157/2025-2026:Supply,conveyance ,installation,testing and commissioning of 18 W Outdoor Garden LED Show light fittings(IP-66) of all types directly in the existing openings on the Gate/Pillar including giving connection with required length of 16/0.20 mm 3 core round copper conductor flex wire conforming to relevant ISS or with the extended original wiring etc as required reputed brand.
ANAS S NEW TECH ASSOCIATES (BID ID -2380981)
Bidder Name
VASTHUSASTHRA BUILDERS AND DEVOLPERS
ANAS S NEW TECH ASSOCIATES
stage.html
html • 0.02 MB
finance_1335483.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .