| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹35.2 L+₹33,762 (0.97%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹37.3 L+₹2.4 L (6.95%)Rejected-AOC | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹39.1 L+₹4.2 L (12.0%)Rejected-AOC | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹39.6 L+₹4.7 L (13.5%)Rejected-AOC | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
19 May 2025, 6:00 pmClosed
Shri Rajesh Kumar Meena, GE
Garrison Engineer (North), 35, Allenby Lines, Secunderabad - 500 087
SPECIAL REPAIRS TO ROOF TREATMENT OF GANDHI BLOCK FACILITY CENTRES PROVN OF ROOF TREATMENT IN BLDG NO P 179 SINGLE OFFRS LIVING AND ADDN ALTN WITH BRICK WORK AND PARAPET WALL IN 36 QTRS IN DHRUVA COMPLEX AT CDM UNDER AGE B R N NO II OF GE NORTH SECU
2025_MES_704914_1
8894
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NORTH SECUNDERABAD
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH) SECUNDERABAD
₹93,000
Yes
24 Jun 2025
21 Apr 2025
26 May 2025
21 Apr 2025
19 May 2025
5 May 2025
Amount
Demolition of cement concrete in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work otherwise specifically provided for roof treatment including removing debris beyond the premises complete all as specified and as directed.
Demolition of cement concrete (un reinforced) of any description and in any position not otherwise specifically provided including roof padding concrete including removing debris beyond the premises complete all as specified and as directed.
M&L Roughening old concrete roof surfaces by picking, sweeping, cleaning and washing down with water to remove dust,etc and applying a coat of neat cement slurry at the rate of 3 Kg per sqm complete all as specified and as directed.
M & L PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in roof paddings, rounded or chamfered on edges complete all asa specified and as directed.
M & L 25 mm thick PCC (1:2:4) Type B0 (using 12.50mm graded stone aggregate) as in roof where require over slabs and finishing the exposed surfaces fair even without using extra cement complete all as specified and directed. Note: PCC as Roof Padding has to be done through RMC only as approved by GE.
M & L Rendering 10 mm thick CM (1:3) on concrete or roof terrace surfaces with using WPC @3% by weight of cement including finishing the surfaces complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M & L Priming the plastered roof surfaces with bituminous primer @ 0.3 Kg/Sqm and laying the APP modified water proofing membrane as perIS 16540-2017/ IS 16532-2017 mineral finish, 3 mm thick and weighing not less than 3.8 kg/sqm reinforced with non woven polyester /HMHDPEmatt black finished over compatible primer/bonding bitumen with 100 mm overlap after necessary preparation of surface complete as per manufacturer’s instructions with bituminous aluminium paint on top @ 0.1ltr/Sqm.complete all as specified.
M&L 40mm thick PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate) as in roof padding finished even and smooth without extra cement complete all as specified and directed. Note: PCC as Roof Padding has to be done through RMC only as approved by GE.
M&L Rendering 10 mm thick CM (1:4) on concrete surfaces of roof, parapet, chajjas, etc with using WPC at rate of 3% by weight of cement and finished the surface with necessary slope complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately
Supply only Integral waterproofing compound complete all as specified and directed.
M&L Cutting out cracks to V-section in existing roofs or terrace,cleaning out,wetting,grouting with cement and sand slurry (1:3) complete all as specified and directed.
M&L Sweeping with wire brushes and cleaning with water over the roof aurfaces and applying one coat of water based bitumen emulsion primer at the rate of 0.3 litres per sqm after cleaning of the surfaces thoroughly from dust, dirt and projections and applying water proofing treatment with APP based polymeric membrane of minimum weight 3.50 Kg per sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 grams per square metre) as per IS 3384 on primed surface by forced application over roof surfaces with the over laps of 10 centimetres over that a coat of blown bitumen of 85 / 25 at the rate of 1.2 kilogram per square metre over that a coat of bituminous aluminium paint at the rate of 100 grams per sqm complete all as specified and as directed.
Demolition of Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed
M & L Brick work with using old size fly ash bricks straight or curved on plan exceeding 6 metre mean radius built in CM (1:6) complete all as specified and as directed.
M & L Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:6) complete all as specified and as directed.
M & L Rendering 15mm thick CM (1:3) on fair faces of brick work or concrete surfaces in wall/chajja with using WPC @3% by weight of cement including finishing the surfaces even and smooth without using extra cement all as specified and directed.
M & L Rendering 15mm thick in CM (1:4) on brick or concrete surfaces finishing the surfaces even and fair complete all as specified an directed.
M & L Preparation of new plastered surfacesand applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed.
Dismantling Single layer Mangalore pattern tiles in roofing including cement mortar bed complete all as specified and as directed.
M & L Mangalore pattern tiles with terracotta colour finish of approved pattern & design over roof set and jointed in cementious water proofing compound and pointed in white or coloured cement to match over and including 15 mm thick screed bed in CM (1:4) complete all as specified and as directed.
S & F Rotational moulded polyethylene water storage tank 3 layer white colour water tank , non- toxic effect, algae formation protection (made from Virgin grade of polyethylene material which is duly stablized with anti-oxident Plastic) of capacity 500 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) and stop valves for 20mm/25mm of bore pipe, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends etc complete including dismantling existing water tank all as specified and directed. MAKE :- Cat No. HSWS-0050-02-Pure of M/s SINTEX
S & F Rotational moulded polyethylene water storage tank 3 layer white colour water tank , non- toxic effect, algae formation protection (made from Virgin grade of polyethylene material which is duly stabilized with anti-oxident Plastic) of capacity 1000 litres, (cylindrical vertical one piece moulded with closed top), the internal and external surfaces of tanks are smooth, clean and free from any hidden internal defects, hoisted and fixed in position including S & F necessary GI fittings, inlet/outlet washout, overflow pieces long nipples, checknuts & washer, 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210gms) and stop valves for 20mm/25mm bore pipe, cast copper alloy, screwed down high pressure with crutch or butterfly handle screwed both ends etc complete including dismantling existing water tank all as specified and directed. MAKE :- Cat No. HSWS-0100-01-Pure of M/s SINTEX
S & F 20 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed.
S & F 25 mm CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified and as directed.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed.
S & F in repairs PVC (SWR) door Bend 110mm dia complete all as specified and as directed.
S & F in repairs PVC (SWR) door Bend 75mm dia complete all as specified and as directed.
S & F in repairs PVC (SWR) single T 75mm dia complete all as specified and as directed.
S & F in repairs PVC (SWR) single T 110 mm dia complete all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories)
M&L Cutting chases, pinning in, in brick wall making good to facings where required and pointing in CM 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc. and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, in CM 1:3 cutting not exceeding 10cm girth complete all as specified and directed.
S & F in repairs PVC (SWR) pipes 75mm bore double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S & F in repairs PVC (SWR) pipes 75mm bore double socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed
S & F in repairs PVC (SWR) pipes 110mm bore double socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed
S & F in repairs PVC (SWR) pipes 110mm bore double socketed, in any length with rubber ring joints, fixed on walls complete all as specified and directed
Taking down and refixing serviceable submain wiring of any size upto 10 sqmm including PVC conduit and making good the disturbed surfaces so as to match with the existing finishes complete all as specified and directed by Engg in Charge.Note: Relaying of conduit for submain wiring and all connections of submain wiring shall be inclusive of rate quoted by contractor.
Disconnecting the Electrical connection, removing the copper line, discharge line of Split AC 1.5/2.0 Ton capacity including indoor and outdoor units and all accessories and re-installing at the same location and testing the whole unit of Split AC in new location and checking the leakage of Split type 1.5/2.0 Ton AC with the help of N2 Gas and after defecting and repairing the leakage, charge the sutiable refrigerant upto required level as specfied in suitable size and length of copper pipe and making the holes in wall complete all as specfied and directed by Engg in Charge.
S&F in replacement of unserviceable Rigid non-metallic PVC conduit 32 mm inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
S&F in replacement of unserviceable Rigid non-metallic PVC conduit 25 mm inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
S&F in replacement of unserviceable Rigid non-metallic PVC conduit 40 mm inclusive of boxes (junction/terminal), all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and directed.
SKY CONSTRUCTIONS (BID ID -3294568)
K LAKSHMAN SINGH AND CO (BID ID -3295332)
BV SAYANNA SONS (BID ID -3294411)
SHAH ENTERPRISES (BID ID -3295217)
M/S VASU ENGINEERS (BID ID -3299780)
KIRAN CONSTRUCTIONS (BID ID -3300138)
MVS ENTERPRISES (BID ID -3295492)
Squad 7 Projects and Services Pvt Ltd (BID ID -3295574)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .