| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.6 LAccepted-AOC 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹14.6 L Quoted ₹15.4 L | L1 | Accepted-AOC Awarded being the Lowest Bidder |
| 2 | L2₹19.4 LRejected-Finance | ₹19.4 L | L2 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | M/s Shiv Builder and Suppliers L1 | J AND T Enterprises L2 |
|---|---|---|---|---|---|
| 1.00 | S&F in repair rotary type hermetically sealed compressor suitable for 1.5 TR split AC unit, ISI marked, including installation, testing and commissioning complete as per manufacturer’s specification complete all as specified and as directed. | 18 | EACH | 13,000 ₹2.3 L | 13,500 ₹2.4 L |
| 2.00 | S&F in repair copper condenser coil for 1.5 TR split AC, heavy gauge, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. | 20 | EACH | 700 ₹14,000 | 3,500 ₹70,000 |
| 3.00 | S&F in repair evaporator coil with anti-corrosive coating for 1.5 TR split AC, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. | 25 | EACH | 3,000 ₹75,000 | 3,000 ₹75,000 |
| 4.00 | Supply and laying in repair soft drawn copper refrigerant pipe 5/8" and 1/4" pair with 19mm nitrile rubber insulation, ISI marked, including supports and installation, complete all as specified and as directed by Engr-in-Charge. | 300 | RM | 500 ₹1.5 L | 400 ₹1.2 L |
| 5.00 | S&F in repair 25mm PVC drain pipe with clamps and accessories, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | 200 | RM | 65 ₹13,000 | 55 ₹11,000 |
| 6.00 | S&F in repair 19mm thick nitrile rubber insulation for suction and liquid line, ISI marked, including installation, complete all as specified and as directed by Engr-in-Charge. | 200 | RM | 60 ₹12,000 | 60 ₹12,000 |
| 7.00 | S&F in repair 3 core, 2.5 sqmm copper flexible cable, ISI marked, including wiring from indoor to outdoor unit, complete all as specified and as directed by Engr-in-Charge. | 250 | RM | 85 ₹21,250 | 210 ₹52,500 |
| 8.00 | S&F in repair 40 mfd capacitor for AC compressor, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | 25 | EACH | 120 ₹3,000 | 500 ₹12,500 |
| 9.00 | Supply, install and testing in repair digital programmable thermostat for split AC, ISI marked, complete all as specified and as directed by Engr-in-Charge. | 25 | EACH | 1,000 ₹25,000 | 200 ₹5,000 |
| 10.00 | S&F in repair PCB control board for 1.5 TR split AC, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | 20 | EACH | 4,500 ₹90,000 | 3,000 ₹60,000 |
Updated dates
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
8 Apr 2026, 6:00 pmClosed
GE (AF) JODHPUR
GE (AF) Jodhpur
COMPREHENSIVE MAINT OF AIR CONDITIONER (SPLIT AND WINDOW AC) AND ALLIED WORKS AT AF STN JODHPUR
2026_MES_752995_2
8463/E8
Open Tender
Civil Works - Roads
180 days
GE (AF) JODHPUR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) Jodhpur
₹40,000
Yes
29 May 2026
20 Mar 2026
11 Apr 2026
20 Mar 2026
8 Apr 2026
27 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1S&F in repair rotary type hermetically sealed compressor suitable for 1.5 TR split AC unit, ISI marked, including installation, testing and commissioning complete as per manufacturer’s specification complete all as specified and as directed. | |||||
| 2S&F in repair copper condenser coil for 1.5 TR split AC, heavy gauge, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. | |||||
| 3S&F in repair evaporator coil with anti-corrosive coating for 1.5 TR split AC, ISI marked, including installation, testing and commissioning, complete all as specified and as directed by Engr-in-Charge. | |||||
| 4Supply and laying in repair soft drawn copper refrigerant pipe 5/8" and 1/4" pair with 19mm nitrile rubber insulation, ISI marked, including supports and installation, complete all as specified and as directed by Engr-in-Charge. | |||||
| 5S&F in repair 25mm PVC drain pipe with clamps and accessories, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | |||||
| 6S&F in repair 19mm thick nitrile rubber insulation for suction and liquid line, ISI marked, including installation, complete all as specified and as directed by Engr-in-Charge. | |||||
| 7S&F in repair 3 core, 2.5 sqmm copper flexible cable, ISI marked, including wiring from indoor to outdoor unit, complete all as specified and as directed by Engr-in-Charge. | |||||
| 8S&F in repair 40 mfd capacitor for AC compressor, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | |||||
| 9Supply, install and testing in repair digital programmable thermostat for split AC, ISI marked, complete all as specified and as directed by Engr-in-Charge. | |||||
| 10S&F in repair PCB control board for 1.5 TR split AC, ISI marked, including installation and testing, complete all as specified and as directed by Engr-in-Charge. | |||||
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
BOQ_848045.xls
BOQ • 0.31 MB
8463Tender.pdf
Tender Documents • 5.68 MB
Download all tender documents and submit your bid